Paper spray mass spectrometry for the direct, semi-quantitative measurement of fentanyl and norfentanyl in complex matrices

被引:55
作者
Vandergrift, Gregory W. [1 ,2 ]
Hessels, Arden J. [1 ]
Palaty, Jan [3 ]
Krogh, Erik T. [1 ,2 ]
Gill, Chris G. [1 ,2 ,4 ,5 ]
机构
[1] Vancouver Isl Univ, Dept Chem, AERL, 900 Fifth St, Nanaimo, BC V9R 5S5, Canada
[2] Univ Victoria, Dept Chem, Victoria, BC, Canada
[3] LifeLabs Med Labs, Burnaby, BC, Canada
[4] Simon Fraser Univ, Dept Chem, Burnaby, BC, Canada
[5] Univ Washington, Dept Environm & Occupat Hlth Sci, Seattle, WA 98195 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Paper spray; Tandem mass spectrometry; Ambient ionization; Fentanyl; Norfentanyl; Opioid harm reduction; QUANTITATIVE-ANALYSIS; HUMAN PLASMA; SAMPLES; URINE; BLOOD; METABOLISM; PRODUCTS; ANALOGS; DRUGS;
D O I
10.1016/j.clinbiochem.2018.02.005
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Fentanyl is a potent, synthetic opioid at the centre of an international health crisis that has seen thousands of fatal overdoses. Most analytical methods focus on the detection of fentanyl in blood and/or urine (i.e., post-drug use). Harm reduction (including pre-screening before drug use) may be an effective strategy against fentanyl overdoses. Method: Paper spray-mass spectrometry (PS-MS) is an inexpensive, direct sampling strategy where a small volume of sample (< 10 mu L) is spotted onto a piece of paper that is then wetted and connected to high voltage. Ions are emitted from the paper and enter a mass spectrometer for sensitive and selective semi-quantitation using labeled internal standards. Results: We present the use of PS-MS for the direct measurement of fentanyl and norfentanyl using a custom PS interface, demonstrating that paper tip position and quality can significantly affect quantitative results. Furthermore, we observe comparable calibrations for fentanyl and norfentanyl (0.5 to 600 ng/mL) across a variety of complex matrices (methanol, diluted urine, analgesic slurry). Detection limits for fentanyl are as low as 0.049 ng/mL (0.4 pg total material) in methanol, and 0.66 ng/mL (5.3 pg total material) spiked in an analgesic slurry (illicit substance simulation). PS-MS was compared with liquid chromatography-MS for the analyses of real urine samples, with satisfactory results. Conclusion: PS-MS shows potential as a sensitive and selective direct measurement strategy for use in fentanyl harm reduction strategies, and may also be used for pre- screening in advance of or in combination with more conventional (i.e., chromatographic) analyses.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 30 条
  • [1] Baselt R. C., 2011, DISPOSITION TOXIC DR, P675
  • [2] A Field-Portable Membrane Introduction Mass Spectrometer for Real-time Quantitation and Spatial Mapping of Atmospheric and Aqueous Contaminants
    Bell, Ryan J.
    Davey, Nicholas G.
    Martinsen, Morten
    Collin-Hansen, Christian
    Krogh, Erik T.
    Gill, Christopher G.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (02) : 212 - 223
  • [3] Development, validation and application of an HPLC-MS/MS method for the determination of fentanyl and nor-fentanyl in human plasma and saliva
    Bista, Sudeep R.
    Lobb, Michael
    Haywood, Alison
    Hardy, Janet
    Tapuni, Angela
    Norris, Ross
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 27 - 33
  • [4] Burnaby B. C., 2017, FENTANYL DETECTED IL, P1
  • [5] Rapid Analysis of Bisphenol A and Its Analogues in Food Packaging Products by Paper Spray Ionization Mass Spectrometry
    Chen, Shuo
    Chang, Quanying
    Yin, Kai
    He, Qunying
    Deng, Yongxiu
    Chen, Bo
    Liu, Chengbin
    Wang, Ying
    Wang, Liping
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (23) : 4859 - 4865
  • [6] Cooks R Graham, 2013, Mass Spectrom (Tokyo), V2, pS0001, DOI 10.5702/massspectrometry.S0001
  • [7] Spray mechanism in paper spray ionization
    Espy, Ryan D.
    Muliadi, Ariel R.
    Ouyang, Zheng
    Cooks, R. Graham
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 325 : 167 - 171
  • [8] Fenn J.B., 2001, Method and Apparatus for Electrospray Ionization
  • [9] Addressing the Fentanyl Threat to Public Health
    Frank, Richard G.
    Pollack, Harold A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2017, 376 (07) : 605 - 607
  • [10] GAS-CHROMATOGRAPHIC DETERMINATION OF FENTANYL AND ITS ANALOGS IN HUMAN-PLASMA
    GILLESPIE, TJ
    GANDOLFI, AJ
    MAIORINO, RM
    VAUGHAN, RW
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1981, 5 (03) : 133 - 137