Multi-Line Transmission in 3-D With Reduced Crosstalk Artifacts: A Proof of Concept Study

被引:37
作者
Denarie, Bastien [1 ]
Bjastad, Tore [1 ]
Torp, Hans [1 ]
机构
[1] Norwegian Univ Sci & Technol, MI Lab, N-7034 Trondheim, Norway
关键词
FRAME RATE ULTRASONOGRAPHY; ULTRASOUND; PROPAGATION; SIMULATION;
D O I
10.1109/TUFFC.2013.2752
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Multi-line transmission (MLT) is a technique in which ultrasound pulses for several directions are transmitted simultaneously. The purpose is increased frame rate, which is especially important in 3-D echocardiography. Compared with techniques purely based on parallel beamformation, MLT avoids the need for reducing the transmit aperture and thus maintains a high harmonic signal level. The main disadvantage is that artifacts are caused by cross-talk between the simultaneous beams. In a conventional MLT implementation, simultaneous transmits would be spaced regularly in the azimuth and elevation planes. However, using rectangular geometry arrays, most of the acoustic side-lobe energy is concentrated along these planes. The results in this work show that the crosstalks can be pushed below the typical display range of 50 dB used in cardiac applications if the parallel transmit directions are aligned along the transverse diagonal of the array. Dispositions with 2 to 5 MLT for a typical cardiac 2-D phased-array were investigated using simulation software. Using the proposed alignment, the maximal crosstalk artifact amplitudes decreased 20 to 30 dB compared with conventional MLT dispositions. In water-tank measurements, side-lobe levels of a commercially available rectangular probe were 15 to 25 dB lower along the transverse diagonal, confirming that similar suppressions can be expected using actual transducers.
引用
收藏
页码:1708 / 1718
页数:11
相关论文
共 31 条
  • [1] Angelsen B. R., 1986, DOPPLER ULTRASOUND I
  • [2] ANGELSEN BAJ, 2000, ULTRASOUND IMAGING
  • [3] Badano L. P., 2011, TEXTBOOK OF REAL TIM, V129
  • [4] Bradley C., 2008, RETROSPECTIVE TRANSM
  • [5] Volume stitching in three-dimensional echocardiography: Distortion analysis and extension to real time
    Brekke, Svein
    Rabben, Stein I.
    Stoylen, Asbjorn
    Haugen, Asbjorn
    Haugen, Geir U.
    Steen, Erik N.
    Torp, Hans
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (05) : 782 - 796
  • [6] Cobbold R. S., 2006, Foundations of biomedical ultrasound
  • [7] Couade Mathieu, 2009, 2009 IEEE International Ultrasonics Symposium, P515, DOI 10.1109/ULTSYM.2009.5441640
  • [8] Parallel Transmit Beamforming Using Orthogonal Frequency Division Multiplexing Applied to Harmonic Imaging-A Feasibility Study
    Demi, Libertario
    Verweij, Martin D.
    van Dongen, Koen W. A.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (11) : 2439 - 2447
  • [9] Denarie B., 2011, IEEE ULTR S, P136
  • [10] Coherent Plane Wave Compounding for Very High Frame Rate Ultrasonography of Rapidly Moving Targets
    Denarie, Bastien
    Tangen, Thor Andreas
    Ekroll, Ingvild Kinn
    Rolim, Natale
    Torp, Hans
    Bjastad, Tore
    Lovstakken, Lasse
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (07) : 1265 - 1276