Interface horizontal shear strength in composite decks with precast concrete panels

被引:7
|
作者
Kumar, NVVP [1 ]
Ramirez, JA [1 ]
机构
[1] PURDUE UNIV,SCH CIVIL ENGN,W LAFAYETTE,IN 47907
来源
PCI JOURNAL | 1996年 / 41卷 / 02期
关键词
bridges; connectors; deck panels; precast concrete; prestressed concrete; research; shear connectors; stay-in-place panels; testing;
D O I
10.15554/pcij.03011996.42.55
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Six stay-in-place precast, prestressed deck panels were tested to evaluate the horizontal shear strength between the precast panel and the cast-in-place portion of the bridge deck. The shear connectors are placed across a broom finished deck panel surface. Broom finish with approximately 0.05 to 0.075 in. (1.27 to 1.91 mm) total amplitude deformations is specified instead of a raked finish with 0.25 in. (6.35 mm) total amplitude because of the reduced 2.5 in. (63.5 mm) thickness of the panels used in Indiana. In this study, composite behavior at ultimate, including horizontal shear and interface slip characteristics, was evaluated. It is concluded that stay-in-place precast, prestressed deck panels with a broom finished surface do not require horizontal shear connectors ii the nominal average horizontal shear stress at the interface is less than 116 psi (0.8 MPa).
引用
收藏
页码:42 / &
页数:15
相关论文
共 50 条
  • [1] Evaluation of Design Provisions for Horizontal Shear Strength in Composite Precast Concrete Beams with Different Interface Conditions
    Oh, Young-Hun
    Moon, Jeong-Ho
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [2] Strength of shear connection in composite bridges with precast decks using high performance concrete and shear-keys
    D. L. Araújo
    M. K. El Debs
    Materials and Structures, 2005, 38 : 173 - 181
  • [3] Strength of shear connection in composite bridges with precast decks using high performance concrete and shear-keys
    Araújo, DL
    El Debs, MK
    MATERIALS AND STRUCTURES, 2005, 38 (276) : 173 - 181
  • [4] Shear strength at the interface of precast bridge concrete decks and girders subjected to cyclic loading with varying speeds
    Leblouba, Moussa
    Barakat, Samer
    Ahmed, Mohammed S. A.
    Al-Toubat, Salah
    ENGINEERING STRUCTURES, 2019, 196
  • [5] Design of shear connection in composite steel and concrete bridges with precast decks
    Shim, CS
    Lee, PG
    Chang, SP
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (03) : 203 - 219
  • [6] Shear strength of GFRP reinforced precast lightweight concrete panels
    Liu, Ruifen
    Pantelides, Chris P.
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 48 : 51 - 58
  • [7] Horizontal connections for precast concrete shear wall panels under cyclic shear loading
    Soudki, KA
    West, JS
    Rizkalla, SH
    Blackett, B
    PCI JOURNAL, 1996, 41 (03): : 64 - 80
  • [8] Shear behavior of shear stud groups in precast concrete decks
    Wang Yu-Hang
    Yu Jie
    Liu Jie-Peng
    Chen, Y. Frank
    ENGINEERING STRUCTURES, 2019, 187 (73-84) : 73 - 84
  • [9] Control of Cracking in Precast, Prestressed Concrete Panels for Bridge Decks
    Kwon, K. Y.
    Foreman, J. M., Jr.
    Azimov, U. U.
    Klingner, R. E.
    Bayrak, O.
    Jirsa, J. O.
    ACI STRUCTURAL JOURNAL, 2014, 111 (06) : 1461 - 1467
  • [10] ANALYSIS OF HORIZONTAL SHEAR STRENGTH OF PRECAST PRESTRESSED CONCRETE SLAB AND CONCRETE TOPPING COMPOSITES
    Wilaiwong, Duttawan
    Vivitkeyoonvong, Somphothi
    INTERNATIONAL TRANSACTION JOURNAL OF ENGINEERING MANAGEMENT & APPLIED SCIENCES & TECHNOLOGIES, 2019, 10 (03): : 373 - 382