Transesophageal Echocardiography for Cardiac Thromboembolic Risk Assessment in Patients With Severe, Symptomatic Aortic Valve Stenosis Referred for Potential Transcatheter Aortic Valve Implantation

被引:13
作者
Lenders, Guy D. [1 ]
Paelinck, Bernard P. [1 ]
Wouters, Kristien [2 ]
Claeys, Marc J. [1 ]
Rodrigus, Inez E. [1 ]
Van Herck, Paul L. [1 ]
Vrints, Christiaan J. [1 ]
Bosmans, Johan M. [1 ]
机构
[1] Univ Antwerp Hosp, Dept Cardiol & Cardiac Surg, Edegem, Belgium
[2] Univ Antwerp Hosp, Dept Sci Coordinat & Biostat, Edegem, Belgium
关键词
SPONTANEOUS ECHO CONTRAST; ATRIAL-FIBRILLATION; EUROPEAN-SOCIETY; STROKE; REPLACEMENT; MANAGEMENT; FREQUENCY; THROMBUS; EVENTS; TAVI;
D O I
10.1016/j.amjcard.2013.01.302
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stroke is a devastating complication after transcatheter aortic valve implantation (TAVI) and might partially be related to cardiac embolization. The aim of this single-center prospective study was to determine the incidence of intracardiac thrombi and left atrial spontaneous echo contrast (SEC), both known predictors of cardiac embolic stroke, in patients referred for potential TAVI. One hundred four consecutive patients with severe symptomatic aortic valve stenosis and at high or very high risk for surgery were included and underwent transesophageal echocardiography. In 11 patients (10.6%), intracardiac thrombi were detected, and 25 patients (24%) showed dense grade 2 SEC. Atrial fibrillation (p <0.0001), diastolic dysfunction (p = 0.0005), and atrial size (p = 0.0038) were related to the presence of intracardiac thrombus and/or dense SEC on multivariate analysis. In conclusion, the incidence of intracardiac thrombi and dense SEC in (very) high-risk patients with severe aortic valve stenosis referred for potential TAVI is high and can accurately be detected using transesophageal echocardiography. Systematic thromboembolic evaluation using transesophageal echocardiography is thus recommended in patients referred for TAVI. (c) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1470 / 1474
页数:5
相关论文
共 29 条
[1]  
Arrigo F, 1993, Cardiologia, V38, P301
[2]   Pathophysiologic correlates of thromboembolism in nonvalvular atrial fibrillation: II. Dense spontaneous echocardiographic contrast (The Stroke Prevention in Atrial Fibrillation [SPAF-III] study) [J].
Asinger, RW ;
Koehler, J ;
Pearce, LA ;
Zabalgoitia, M ;
Blackshear, JL ;
Fenster, PE ;
Strauss, R ;
Hess, D ;
Pennock, GD ;
Rothbart, RM ;
Halperin, JL .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (12) :1088-1096
[3]   Patients with atrial fibrillation and dense spontaneous echo contrast at high risk -: A prospective and serial follow-up over 12 months with transesophageal echocardiography and cerebral magnetic resonance imaging [J].
Bernhardt, P ;
Schmidt, H ;
Hammerstingl, C ;
Lüderitz, B ;
Omran, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (11) :1807-1812
[4]   Procedural, 30-day and one year outcome following CoreValve or Edwards transcatheter aortic valve implantation: results of the Belgian national registry [J].
Bosmans, Johan M. ;
Kefer, Joelle ;
De Bruyne, Bernard ;
Herijgers, Paul ;
Dubois, Christophe ;
Legrand, Victor ;
Verheye, Stephan ;
Rodrigus, Inez .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 12 (05) :762-766
[5]   LEFT ATRIAL SPONTANEOUS ECHO CONTRAST IS HIGHLY ASSOCIATED WITH PREVIOUS STROKE IN PATIENTS WITH ATRIAL-FIBRILLATION OR MITRAL-STENOSIS [J].
CHIMOWITZ, MI ;
DEGEORGIA, MA ;
POOLE, RM ;
HEPNER, A ;
ARMSTRONG, WM .
STROKE, 1993, 24 (07) :1015-1019
[6]   Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients [J].
Eggebrecht, Holger ;
Schmermund, Axel ;
Voigtlaender, Thomas ;
Kahlert, Philipp ;
Erbel, Raimund ;
Mehta, Rajendra H. .
EUROINTERVENTION, 2012, 8 (01) :129-138
[7]   Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation† [J].
Erdoes, Gabor ;
Basciani, Reto ;
Huber, Christoph ;
Stortecky, Stefan ;
Wenaweser, Peter ;
Windecker, Stephan ;
Carrel, Thierry ;
Eberle, Balthasar .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (04) :778-784
[8]   Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status [J].
Fairbairn, Timothy A. ;
Mather, Adam N. ;
Bijsterveld, Petra ;
Worthy, Gillian ;
Currie, Stuart ;
Goddard, Anthony J. P. ;
Blackman, Daniel J. ;
Plein, Sven ;
Greenwood, John P. .
HEART, 2012, 98 (01) :18-23
[9]   The utility of transoesophageal echocardiography to determine management in suspected embolic stroke [J].
Galougahi, K. K. ;
Stewart, T. ;
Choong, C. Y. P. ;
Storey, C. E. ;
Yates, M. ;
Tofler, G. H. .
INTERNAL MEDICINE JOURNAL, 2010, 40 (12) :813-818
[10]   Effect of Elevated Left Ventricular Diastolic Filling Pressure on the Frequency of Left Atrial Appendage Thrombus in Patients With Nonvalvular Atrial Fibrillation [J].
Iwakura, Katsuomi ;
Okamura, Atsushi ;
Koyama, Yasushi ;
Date, Motoo ;
Higuchi, Yoshiharu ;
Inoue, Koichi ;
Kimura, Ryusuke ;
Nagai, Hiroyuki ;
Toyoshima, Yuko ;
Ozawa, Makito ;
Ito, Norihisa ;
Shibuya, Masahiko ;
Omiya, Shigemiki ;
Takagi, Takashi ;
Morisawa, Daisuke ;
Fujii, Kenshi .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (03) :417-422