Numerical analysis on thermal performance of naturally ventilated roofs with different influencing parameters

被引:52
作者
Li, Dong [1 ]
Zheng, Yumeng [1 ]
Liu, Changyu [1 ]
Qi, Hanbing [1 ]
Liu, Xiaoyan [1 ]
机构
[1] Northeast Petr Univ, Sch Architecture & Civil Engn, Daqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Ventilated roof; Residential building; Thermal performance; PHASE-CHANGE MATERIALS; HEAT-TRANSFER; COMMERCIAL BUILDINGS; COOLING LOAD; SOLAR ROOF; AIR-FLOW; ENERGY; CONVECTION; DESIGN; SYSTEM;
D O I
10.1016/j.scs.2016.02.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ventilated roof can reduce the cooling load during summer period by decreasing transmitted heat flux of the building structures exposed to the solar radiation. In the present work, effect of different influencing parameters on thermal performance of naturally ventilated roofs on a residential building in Northeast China has been investigated numerically based on computational fluid dynamics (CFD), such as air gap thickness, roof slope, exhaust outlet size and absorption coefficient of external roof surface. The results show that the effect of ventilated layer on the temperature delay of roofs is strong, but the effect on the delay time is relatively weak. The air layer thickness, roof slope and exhaust outlet size also play an important role in the thermal performance of ventilated roof. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 48 条
  • [1] Hygrothermal behaviour of flat cool and standard roofs on residential and commercial buildings in North America
    Ahrab, Mohammad Ali Moghaddaszadeh
    Akbari, Hashem
    [J]. BUILDING AND ENVIRONMENT, 2013, 60 : 1 - 11
  • [2] A review of the potential of attic ventilation by passive and active turbine ventilators in tropical Malaysia
    Al-Obaidi, Karam M.
    Ismail, Mazran
    Rahman, Abdul Malek Abdul
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2014, 10 : 232 - 240
  • [3] Design and performance of a novel innovative roofing system for tropical landed houses
    Al-Obaidi, Karam M.
    Ismail, Mazran
    Rahman, Abdul Malek Abdul
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 488 - 504
  • [4] Transition of free convection flow inside an inclined parallel walled channel: Effects of inclination angle and width of the channel
    Alzwayi, Ali S.
    Paul, Manosh C.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 68 : 194 - 202
  • [5] Heat transfers in a double-skin roof ventilated by natural convection in summer time
    Biwole, P. H.
    Woloszyn, M.
    Pompeo, C.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (08) : 1487 - 1497
  • [6] Determination of transient two-dimensional heat transfer in ventilated lightweight low sloped roof using Fourier series
    Cerne, Bostjan
    Medved, Saso
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (06) : 2279 - 2288
  • [7] Evaluation of Overall Thermal Transfer Value (OTTV) for commercial buildings constructed with green roof
    Chan, A. L. S.
    Chow, T. T.
    [J]. APPLIED ENERGY, 2013, 107 : 10 - 24
  • [8] Effect of energy efficient building elements on summer cooling of buildings
    Charde, Meghana
    Gupta, Rajiv
    [J]. ENERGY AND BUILDINGS, 2013, 67 : 616 - 623
  • [9] A new design of metal-sheet cool roof using PCM
    Chou, Huann-Ming
    Chen, Chang-Ren
    Vu-Lan Nguyen
    [J]. ENERGY AND BUILDINGS, 2013, 57 : 42 - 50
  • [10] Energy analysis of ventilated and microventilated roofs
    Ciampi, M
    Leccese, F
    Tuoni, G
    [J]. SOLAR ENERGY, 2005, 79 (02) : 183 - 192