Performance of low-cost monitors to assess household air pollution

被引:34
作者
Curto, A. [1 ,2 ,3 ]
Donaire-Gonzalez, D. [1 ,2 ,3 ]
Barrera-Gomez, J. [1 ,2 ,3 ]
Marshall, J. D. [4 ]
Nieuwenhuijsen, M. J. [1 ,2 ,3 ]
Wellenius, G. A. [5 ]
Tonne, C. [1 ,2 ,3 ]
机构
[1] ISGIobal, Ctr Res Environm Epidemiol CREAL, Barcelona, Spain
[2] UPF, Barcelona, Spain
[3] CIBERESP, Barcelona, Spain
[4] Univ Washington, Dept Civil & Environm Engn, Seattle, WA 98195 USA
[5] Brown Univ, Sch Publ Hlth, Dept Epidemiol, Providence, RI 02912 USA
基金
欧洲研究理事会;
关键词
Household air pollution; Particulate matter; Carbon monoxide; Air quality sensing; Low cost instrument; PARTICULATE MATTER; CARBON-MONOXIDE; PERSONAL EXPOSURE; BIOMASS FUELS; SENSORS; PM2.5; QUALITY; STOVES; EMISSIONS; COOKING;
D O I
10.1016/j.envres.2018.01.024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Exposure to household air pollution is a leading cause of morbidity and mortality globally. However, due to the lack of validated low-cost monitors with long-lasting batteries in indoor environments, most epidemiologic studies use self-reported data or short-term household air pollution assessments as proxies of long-term exposure. We evaluated the performance of three low-cost monitors measuring fine particulate matter (PM2.5) and carbon monoxide (CO) in a wood-combustion experiment conducted in one household of Spain for 5 days (including the co-location of 2 units of HAPEX and 3 units of TZOA-R for PM2.5 and 3 units of EL-USB-CO for CO; a total of 40 unit-days). We used Spearman correlation (p) and Concordance Correlation Coefficient (CCC) to assess accuracy of low-cost monitors versus equivalent research-grade devices. We also conducted a field study in India for 1 week (including HAPEX in 3 households and EL-USB-CO in 4 households; a total of 49 unit-days). Correlation and agreement at 5-min were moderate-high for one unit of HAPEX (p = 0.73 / CCC = 0.59), for one unit of TZOA-R (p = 0.89 / CCC = 0.62) and for three units of EL-USB-CO (p = 0.82-0.89 / CCC = 0.66-0.91) in Spain, although the failure or malfunction rate among low-cost units was high in both settings (60% of unit-days in Spain and 43% in India). Low-cost monitors tested here are not yet ready to replace more established exposure assessment methods in long-term household air pollution epidemiologic studies. More field validation is needed to assess evolving sensors and monitors with application to health studies.
引用
收藏
页码:53 / 63
页数:11
相关论文
共 66 条
[1]  
Air Quality-Sensor Performance Evaluation Center (AQ-SPEC), FIELD EV COMM AV LOW
[2]   Development of a normalized multi-sensors system for low cost on-line atmospheric pollution detection [J].
Al Barakeh, Zaher ;
Breuil, Philippe ;
Redon, Nathalie ;
Pijolat, Christophe ;
Locoge, Nadine ;
Viricelle, Jean-Paul .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 :1235-1243
[3]   Review of Small Commercial Sensors for Indicative Monitoring of Ambient Gas [J].
Aleixandre, Manuel ;
Gerboles, Michel .
NOSE 2012: 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ODOUR MONITORING AND CONTROL, 2012, 30 :169-174
[4]  
[Anonymous], ENV POLLUT, DOI 10.10164envpo1.2016.12.045
[5]  
Balakrishnan K., 2004, Indoor Air Pollution Associated with Household Fuel Use in India An exposure assessment and modeling exercise in rural districts of Andhra Pradesh, India
[6]   Patterns of domestic exposure to carbon monoxide and particulate matter in households using biomass fuel in Janakpur, Nepal [J].
Bartington, S. E. ;
Bakolis, I. ;
Devakumar, D. ;
Kurmi, O. P. ;
Gulliver, J. ;
Chaube, G. ;
Manandhar, D. S. ;
Saville, N. M. ;
Costello, A. ;
Osrin, D. ;
Hansell, A. L. ;
Ayres, J. G. .
ENVIRONMENTAL POLLUTION, 2017, 220 :38-45
[7]   Impact of improved stoves, house construction and child location on levels of indoor air pollution exposure in young Guatemalan children [J].
Bruce, N ;
McCracken, J ;
Albalak, R ;
Schei, M ;
Smith, KR ;
Lopez, V ;
West, C .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2004, 14 (Suppl 1) :S26-S33
[8]  
Budde M., 2012, INVESTIGATING USE CO, P1, DOI [DOI 10.1109/INSS.2012.6240545, 10.1109/inss.2012.6240545]
[9]   Portable, Ambient PM2.5 Sensor for Human and/or Animal Exposure Studies [J].
Cao, Tingting ;
Thompson, Jonathan E. .
ANALYTICAL LETTERS, 2017, 50 (04) :712-723
[10]   Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates? [J].
Castell, Nuria ;
Dauge, Franck R. ;
Schneider, Philipp ;
Vogt, Matthias ;
Lerner, Uri ;
Fishbain, Barak ;
Broday, David ;
Bartonova, Alena .
ENVIRONMENT INTERNATIONAL, 2017, 99 :293-302