The Choroid Plexus of the Lateral Ventricle As the Origin of CSF Pulsation Is Questionable

被引:20
作者
Takizawa, Ken [1 ]
Matsumae, Mitsunori [1 ]
Hayashi, Naokazu [1 ]
Hirayama, Akihiro [1 ]
Sano, Fumiya [1 ]
Yatsushiro, Satoshi [2 ]
Kuroda, Kagayaki [2 ]
机构
[1] Tokai Univ, Dept Neurosurg, Sch Med, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
[2] Tokai Univ, Dept Biol Engn, Sch Biol Engn, Isehara, Kanagawa, Japan
基金
日本学术振兴会;
关键词
choroid plexus; cerebrospinal fluid; magnetic resonance imaging; image analysis; hydromechanics; CEREBROSPINAL-FLUID CIRCULATION; PRESSURE-GRADIENTS; ARTERIAL PULSATION; FLOW; VELOCITY; HYDROCEPHALUS; VISUALIZATION; MAINTENANCE; RESPIRATION; MOTION;
D O I
10.2176/nmc.oa.2017-0117
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The advent of magnetic resonance imaging (MRI) enables noninvasive measurement of cerebrospinal fluid (CSF) motion, and new information about CSF motion has now been acquired. The driving force of the CSF has long been thought to be choroid plexus (CP) pulsation, but to investigate whether this phenomenon actually occurs, CSF motion was observed in the ventricular system and subarachnoid space using MRI. Eleven healthy volunteers, ranging in age from 23 to 58 years, participated in this study. The MRI sequences used were four-dimensional phase-contrast (4D-PC) and time-spatial labeling inversion pulse (t-SLIP). The 4D-PC images included sagittal images in the cranial midline, coronal images focusing on the foramen of Monro (FOM), and oblique coronal images of the trigone to quantify CSF velocity and acceleration. These values were compared and analyzed as non-parametric data using the Kolmogorov-Smirnov test and the Mann-Whitney U test. 4D-PC showed that the median CSF velocity was significantly lower in the posterior part of the lateral ventricle than in other regions. The quantitative analysis of velocity and acceleration showed that they were decreased around the CP in the trigone. Image analysis of both velocity mapping and t-SLIP showed suppressed CSF motion around the CP in the trigone. These findings cast doubt on CP pulsation being the driving force for CSF motion.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 30 条
  • [21] 2-O
  • [22] ORIGIN OF ARTERIAL PULSATION OF CEREBROSPINAL FLUID
    LAITINEN, L
    [J]. ACTA NEUROLOGICA SCANDINAVICA, 1968, 44 (02): : 168 - &
  • [23] Research into the Physiology of Cerebrospinal Fluid Reaches a New Horizon: Intimate Exchange between Cerebrospinal Fluid and Interstitial Fluid May Contribute to Maintenance of Homeostasis in the Central Nervous System
    Matsumae, Mitsunori
    Sato, Osamu
    Hirayama, Akihiro
    Hayashi, Naokazu
    Takizawa, Ken
    Atsumi, Hideki
    Sorimachi, Takatoshi
    [J]. NEUROLOGIA MEDICO-CHIRURGICA, 2016, 56 (07) : 416 - 441
  • [24] Velocity and pressure gradients of cerebrospinal fluid assessed with magnetic resonance imaging
    Matsumae, Mitsunori
    Hirayama, Akihiro
    Atsumi, Hideki
    Yatsushiro, Satoshi
    Kuroda, Kagayaki
    [J]. JOURNAL OF NEUROSURGERY, 2014, 120 (01) : 218 - 227
  • [25] THIRD CIRCULATION REVISITED
    MILHORAT, TH
    [J]. JOURNAL OF NEUROSURGERY, 1975, 42 (06) : 628 - 645
  • [26] The vascular factor in intracranial pressure and the maintenance of the cerebrospinal fluid circulation.
    O'Connell, JEA
    [J]. BRAIN, 1943, 66 : 204 - 228
  • [27] Picard N, 2015, J NEUROSURG, V122, P479, DOI 10.3171/2014.6.JNS141331
  • [28] ACCURACY OF PHASE-CONTRAST FLOW MEASUREMENTS IN THE PRESENCE OF PARTIAL-VOLUME EFFECTS
    TANG, C
    BLATTER, DD
    PARKER, DL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02): : 377 - 385
  • [29] INTERRUPTION OF ANTERIOR CHOROIDAL ARTERY IN EXPERIMENTAL HYDROCEPHALUS
    WILSON, CB
    BERTAN, V
    [J]. ARCHIVES OF NEUROLOGY, 1967, 17 (06) : 614 - &
  • [30] Visualization of Cerebrospinal Fluid Movement with Spin Labeling at MR Imaging: Preliminary Results in Normal and Pathophysiologic Conditions
    Yamada, Shinya
    Miyazaki, Mitsue
    Kanazawa, Hitoshi
    Higashi, Minako
    Morohoshi, Yukuo
    Bluml, Stefan
    McComb, J. Gordon
    [J]. RADIOLOGY, 2008, 249 (02) : 644 - 652