Circulating microemboli in patients after aortic valve replacement with pulmonary autografts and mechanical valve prostheses

被引:24
作者
Notzold, A
Droste, DW
Hagedorn, G
Berndt, S
Kaps, M
Graf, B
Sievers, HH
机构
[1] UNIV LUBECK,KLIN HERZCHIRURG,D-23538 LUBECK,GERMANY
[2] UNIV LUBECK,DEPT NEUROL,D-23538 LUBECK,GERMANY
[3] UNIV MUNSTER,DEPT NEUROL,D-4400 MUNSTER,GERMANY
[4] KLINIKUM SCHWERIN,DEPT CARDIOL,SCHWERIN,GERMANY
关键词
valves; surgery; embolism; microspheres; cerebrovascular circulation;
D O I
10.1161/01.CIR.96.6.1843
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The pulmonary autograft procedure (Ross) is now considered the gold standard for aortic valve replacement. One of its advantages is the freedom from macroemboli without anticoagulation. Whether this holds true for circulating microemboli, detectable as high-intensity transient Doppler signals (HITS), has not yet been verified. Methods and Results We investigated 8 patients (2 women, 6 men; mean age, 50.6 +/- 17.9 years) after the Ross procedure, 9 patients (3 women, 6 men; mean age, 67.2 +/- 9.46 years) after aortic valve replacement with a mechanical valve prosthesis, and 12 young healthy volunteers by unilateral 1 hour recording of the middle cerebral artery on digital audio tape. Patients with extracranial carotid artery disease were excluded by color duplex sonography. During the off-line evaluation, the investigator was not aware of any patient details. No HITS were detected in healthy volunteers (95% confidence interval [CI], 0% to 26.46%). After the Ross procedure, 1 patient had 11 and 1 patient had 1 HITS (95% CI, 3.19% to 65.09%). All recipients of mechanical valves had HITS, ranging from 2 to 84 per hour (95% CI, 66.7% to 100%). Significantly more recipients of mechanical valves exhibited HITS than recipients of pulmonary autografts (P<.O5) or control subjects (P<.05). Conclusions In contrast to mechanical valves, pulmonary autografts are seldom the source of microemboli, confirming the pulmonary autograft as the superior substitute for aortic valve replacement.
引用
收藏
页码:1843 / 1846
页数:4
相关论文
共 16 条
[1]   CLINICAL CORRELATES OF HIGH-INTENSITY TRANSIENT SIGNALS DETECTED ON TRANSCRANIAL DOPPLER SONOGRAPHY IN PATIENTS WITH CEREBROVASCULAR-DISEASE [J].
BABIKIAN, VL ;
HYDE, C ;
POCHAY, V ;
WINTER, MR .
STROKE, 1994, 25 (08) :1570-1573
[2]  
BRAEKKEN SK, 1995, STROKE, V26, P1225
[3]   THE EFFECT OF DIFFERENT SETTINGS OF ULTRASOUND PULSE AMPLITUDE, GAIN AND SAMPLE VOLUME ON THE APPEARANCE OF EMBOLI STUDIED IN A TRANSCRANIAL DOPPLER MODEL [J].
DROSTE, DW ;
MARKUS, HS ;
BROWN, MM .
CEREBROVASCULAR DISEASES, 1994, 4 (03) :152-156
[4]   COAGULATION ACTIVITY AND EMBOLI COUNTS IN PATIENTS WITH PROSTHETIC CARDIAC VALVES [J].
GEORGIADIS, D ;
MALLINSON, A ;
GROSSET, DG ;
LEES, KR .
STROKE, 1994, 25 (06) :1211-1214
[5]   Transcranial Doppler detection of micro-emboli in prosthetic heart valve patients: Dependency upon valve type [J].
Georgiadis, D ;
Kaps, M ;
Berg, J ;
Mackay, TG ;
Dapper, F ;
Faichney, A ;
Wheatley, DJ ;
Lees, KR .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1996, 10 (04) :253-257
[6]  
GEORGIADIS D, 1994, STROKE, V25, P585
[7]  
GROSSET DG, 1994, J HEART VALVE DIS, V4, P152
[8]   DETECTION OF MIDDLE CEREBRAL EMBOLI DURING CORONARY-ARTERY BYPASS-SURGERY USING TRANSCRANIAL DOPPLER SONOGRAPHY [J].
HARRISON, MJG ;
PUGSLEY, W ;
NEWMAN, S ;
PASCHALIS, C ;
KLINGER, L ;
TREASURE, T ;
ASPEY, B .
STROKE, 1990, 21 (10) :1512-1512
[9]  
Muller H R, 1994, J Heart Valve Dis, V3, P602
[10]  
Rams J J, 1993, J Heart Valve Dis, V2, P37