Automatic virtual impedance adaptation of a knee exoskeleton for personalized walking assistance

被引:26
作者
Chinimilli, Prudhvi Tej [1 ]
Qiao, Zhi [1 ]
Sorkhabadi, Seyed Mostafa Rezayat [1 ]
Jhawar, Vaibhav [1 ]
Fong, Iat Hou [1 ]
Zhang, Wenlong [1 ]
机构
[1] Arizona State Univ, Robot & Intelligent Syst Lab, Polytech Sch, Ira A Fulton Sch Engn, Mesa, AZ 85212 USA
基金
美国国家科学基金会;
关键词
Wearable sensors; Assistive robotics; Human intention estimation; Impedance control; Rehabilitation; MUSCLE-ACTIVITY; DESIGN; REHABILITATION; RECOGNITION; KINEMATICS; TORQUE; ROBOT;
D O I
10.1016/j.robot.2019.01.013
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper attempts to address the problem of online modulation of virtual impedance for an assistive robot based on real-time gait and activity measurements to personalize the assistance for different users at different states. In this work, smart shoes and inertial sensors are introduced to measure ground contact forces and knee joint kinematics, respectively. An automatic impedance tuning (AIT) approach is presented for a knee assistive device (KAD) based on real-time activity recognition and gait phase detection. The activities considered in this paper are level, uphill, and downhill walking. A Gaussian mixture model (GMM) is employed to map the fuzzy likelihood of various activities and gait phases to the desired virtual impedance of the KAD. The prior estimate of virtual impedance is defined using human knee impedance identified with the walking data collected on different users. The AIT approach is integrated into the high-level impedance-based controller of the KAD for assistance during the stance phase. Finally, to evaluate the benefit of the proposed algorithm in stance phase, an EMG sensor is placed on the vastus medialis muscle group of three participants. The proposed approach is compared with two baseline approaches: constant impedance and finite state machine, and the results demonstrate that the profiles of impedance parameters and robot assistive torque are smoother and the muscle activity of vastus medialis is reduced. It is also noticed that the participants reduce their step lengths and increase walking cadence with assistance from the KAD. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 76
页数:11
相关论文
共 40 条
[1]  
[Anonymous], 1995, FUZZY SETS FUZZY LOG
[2]   A robot and control algorithm that can synchronously assist in naturalistic motion during body-weight-supported gait training following neurologic injury [J].
Aoyagi, Daisuke ;
Ichinose, Wade E. ;
Harkema, Susan J. ;
Reinkensmeyer, David J. ;
Bobrow, James E. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2007, 15 (03) :387-400
[3]   Network-Based Rehabilitation System for Improved Mobility and Tele-Rehabilitation [J].
Bae, Joonbum ;
Zhang, Wenlong ;
Tomizuka, Masayoshi .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2013, 21 (05) :1980-1987
[4]   Finite State Control of a Variable Impedance Hybrid Neuroprosthesis for Locomotion After Paralysis [J].
Bulea, Thomas C. ;
Kobetic, Rudi ;
Audu, Musa L. ;
Schnellenberger, John R. ;
Triolo, Ronald J. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2013, 21 (01) :141-151
[5]   Normalisation of gait EMGs: a re-examination [J].
Burden, AM ;
Trew, M ;
Baltzopoulos, V .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (06) :519-532
[6]  
Chinimilli P. T., 2016, ASME DYN SYS CONTR C
[7]  
Chinimilli PT, 2017, P AMER CONTR CONF, P1462, DOI 10.23919/ACC.2017.7963159
[8]   Hybrid FES-robot cooperative control of ambulatory gait rehabilitation exoskeleton [J].
del-Ama, Antonio J. ;
Gil-Agudo, Angel ;
Pons, Jose L. ;
Moreno, Juan C. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
[9]   Lower extremity exoskeletons and active orthoses: Challenges and state-of-the-art [J].
Dollar, Aaron M. ;
Herr, Hugh .
IEEE TRANSACTIONS ON ROBOTICS, 2008, 24 (01) :144-158
[10]   Functional calibration procedure for 3D knee joint angle description using inertial sensors [J].
Favre, J. ;
Aissaoui, R. ;
Jolles, B. M. ;
de Guise, J. A. ;
Aminian, K. .
JOURNAL OF BIOMECHANICS, 2009, 42 (14) :2330-2335