Single and multi-family residential central all-air HVAC system operational characteristics in cooling-dominated climate

被引:45
作者
Cetin, Kristen Sara [1 ]
Novoselac, Atila [1 ]
机构
[1] Univ Texas Austin, Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
Runtime fraction; Duty cycle; Central air conditioning; Single family homes; Multi-family homes; DEMAND RESPONSE; OZONE REMOVAL; INDOOR; PARTICLES; DEPOSITION; BUILDINGS; SURFACES; EXPOSURE; IMPACT; RATES;
D O I
10.1016/j.enbuild.2015.03.039
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
189 conditioned residential single-family and multi-family homes in the cooling-dominated climate of Texas were instrumented with home energy management systems (HEMS) to collect sub-metered data on HVAC operations. This study analyses the HVAC operation from these homes over a 1-year period to determine the duty cycles of the HVAC systems. This includes annual, monthly, and hourly HVAC ON-OFF operation patterns. Regression analysis was used to determine the relationship to HVAC energy use and whole-home energy use, and the influence of building and occupant characteristics. HVAC runtimes are found to be approximately 20% per year, but vary, depending on the season and time of day. Daily and monthly runtime fractions are lowest (10%) at average outdoor temperatures of 15 degrees C, and increase with increasing or decreasing temperature. Hourly runtime peaks at 7 pm in the cooling season, while in the heating and transition seasons, it peaks at 7 am. The number of occupants and the indoor cooling set point temperature were found to most strongly influence the HVAC runtime. The results are formatted to be used in various building and indoor air quality applications where the studied phenomena are influenced by HVAC operation. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:210 / 220
页数:11
相关论文
共 48 条
[1]  
[Anonymous], 2010, GUID DET CLIM REG CO
[2]  
[Anonymous], 2013, ASHRAE 62 2 VENT ACC
[3]  
[Anonymous], 2014, ASHRAE T
[4]   REMOVAL OF REACTIVE GASES AT INDOOR SURFACES - COMBINING MASS-TRANSPORT AND SURFACE KINETICS [J].
CANORUIZ, JA ;
KONG, D ;
BALAS, RB ;
NAZAROFF, WW .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1993, 27 (13) :2039-2050
[5]   Appliance daily energy use in new residential buildings: Use profiles and variation in time-of-use [J].
Cetin, K. S. ;
Tabares-Velasco, P. C. ;
Novoselac, A. .
ENERGY AND BUILDINGS, 2014, 84 :716-726
[6]   Analyzing a database of residential air leakage in the United States [J].
Chan, WYR ;
Nazaroff, WW ;
Price, PN ;
Sohn, MD ;
Gadgil, AJ .
ATMOSPHERIC ENVIRONMENT, 2005, 39 (19) :3445-3455
[7]   Assessing the Influence of Indoor Exposure to "Outdoor Ozone" on the Relationship between Ozone and Short-term Mortality in US Communities [J].
Chen, Chun ;
Zhao, Bin ;
Weschler, Charles J. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2012, 120 (02) :235-240
[8]   Long-term performance of passive materials for removal of ozone from indoor air [J].
Cros, C. J. ;
Morrison, G. C. ;
Siegel, J. A. ;
Corsi, R. L. .
INDOOR AIR, 2012, 22 (01) :43-53
[9]  
DOE, 2010, BUILD EN DAT BOOK EN
[10]   Predictions and determinants of size-resolved particle infiltration factors in single-family homes in the US [J].
El Orch, Zeineb ;
Stephens, Brent ;
Waring, Michael S. .
BUILDING AND ENVIRONMENT, 2014, 74 :106-118