WHOLE BREAST LESION DETECTION USING NAIVE BAYES CLASSIFIER FOR PORTABLE ULTRASOUND

被引:19
|
作者
Yang, Min-Chun [1 ]
Huang, Chiun-Sheng [2 ,3 ]
Chen, Jeon-Hor [4 ,5 ,6 ]
Chang, Ruey-Feng [1 ,7 ]
机构
[1] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Surg, Taipei 100, Taiwan
[3] Natl Taiwan Univ, Coll Med, Taipei 10617, Taiwan
[4] Univ Calif Irvine, Dept Radiol Sci, Ctr Funct Oncoimaging, Irvine, CA 92717 USA
[5] China Med Univ Hosp, Dept Radiol, Taichung, Taiwan
[6] China Med Univ, Sch Med, Dept Med, Taichung, Taiwan
[7] Natl Taiwan Univ, Grad Inst Biomed Elect & Bioinformat, Taipei 10617, Taiwan
关键词
Portable ultrasound; Naive Bayes classifier; Lesion detection; COMPUTER-AIDED DIAGNOSIS; MAGNITUDE MR-IMAGES; CAD-SYSTEM; US; MAMMOGRAPHY; SONOGRAPHY; SPECKLE; MASSES; WOMEN; PERFORMANCE;
D O I
10.1016/j.ultrasmedbio.2012.07.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In recent years, portable PC-based ultrasound (US) imaging systems developed by some companies can provide an integrated computer environment for computer-aided diagnosis and detection applications. In this article, an automatic whole breast lesion detection system based on the naive Bayes classifier using the PC-based US system Terason t3000 (Terason Ultrasound, Burlington, MA, USA) with a hand-held probe is proposed. To easily retrieve the US images for any regions of the breast, a clock-based storing system is proposed to record the scanned US images. A computer-aided detection (CAD) system is also developed to save the physicians' time for a huge volume of scanned US images. The pixel classification of the US is based on the naive Bayes classifier for the proposed lesion detection system. The pixels of the US are classified into two types: lesions or normal tissues. The connected component labeling is applied to find the suspected lesions in the image. Consequently, the labeled two-dimensional suspected regions are separated into two clusters and further checked by two-phase lesion selection criteria for the determination of the real lesion, while reducing the false-positive rate. The free-response operative characteristics (FROC) curve is used to evaluate the detection performance of the proposed system. According to the experimental results of 31 cases with 33 lesions, the proposed system yields a 93.4% (31/33) sensitivity at 4.22 false positives (FPs) per hundred slices. Moreover, the speed for the proposed detection scheme achieves 12.3 frames per second (fps) with an Intel Dual-Core Quad 3 GHz processor and can be also effectively and efficiently used for other screening systems. (E-mail: rfchang@csie.ntu.edu.tw) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1870 / 1880
页数:11
相关论文
共 50 条
  • [21] A hybrid PSO with Naive Bayes classifier for disengagement detection in online learning
    Gopalakrishnan, T.
    Sengottuvelan, P.
    PROGRAM-ELECTRONIC LIBRARY AND INFORMATION SYSTEMS, 2016, 50 (02) : 215 - 224
  • [22] Detection and diagnosis of induction motor bearing faults using multiwavelet transform and naive Bayes classifier
    Saini, Manish Kumar
    Aggarwal, Akanksha
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2018, 28 (08):
  • [23] Signal Classification and Jamming Detection in Wide-Band Radios Using Naive Bayes Classifier
    Mughal, M. O.
    Kim, Sunwoo
    IEEE COMMUNICATIONS LETTERS, 2018, 22 (07) : 1398 - 1401
  • [24] Classification of Diabetic Patients Records Using Naive Bayes Classifier
    Thulasi, K. S.
    Ninu, E. S.
    Kumar, Shiva K. M.
    2017 2ND IEEE INTERNATIONAL CONFERENCE ON RECENT TRENDS IN ELECTRONICS, INFORMATION & COMMUNICATION TECHNOLOGY (RTEICT), 2017, : 1194 - 1198
  • [25] Spam Filtering using Association Rules and Naive Bayes Classifier
    Yang, Tianda
    Qian, Kai
    Lo, Dan Chia-Tien
    Al Nasr, Kamal
    Qian, Ying
    PROCEEDINGS OF 2015 IEEE INTERNATIONAL CONFERENCE ON PROGRESS IN INFORMATCS AND COMPUTING (IEEE PIC), 2015, : 638 - 642
  • [26] Computer-Aided Multiview Tumor Detection for Automated Whole Breast Ultrasound
    Lo, Chiao
    Shen, Yi-Wei
    Huang, Chiun-Sheng
    Chang, Ruey-Feng
    ULTRASONIC IMAGING, 2014, 36 (01) : 3 - 17
  • [27] Comparison of Naive Bayes and logistic regression for computer-aided diagnosis of breast masses using ultrasound imaging
    Cary, Theodore W.
    Cwanger, Alyssa
    Venkatesh, Santosh S.
    Conant, Emily F.
    Sehgal, Chandra M.
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [28] Intelligent diagnosis of flip chip solder bumps using high-frequency ultrasound and a naive Bayes classifier
    Su, Lei
    Liao, Guanglan
    Shi, Tielin
    Zhang, Yichun
    INSIGHT, 2018, 60 (05) : 264 - 269
  • [29] Symmetrical and Asymmetrical Sampling Audit Evidence Using a Naive Bayes Classifier
    Sheu, Guang-Yih
    Liu, Nai-Ru
    SYMMETRY-BASEL, 2024, 16 (04):
  • [30] Emotion Recognition on The Basis of Audio Signal Using Naive Bayes Classifier
    Bhakre, Sagar K.
    Bang, Arti
    2016 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATIONS AND INFORMATICS (ICACCI), 2016, : 2363 - 2367