Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT

被引:21
作者
Peszynska-Piorun, Magdalena [1 ]
Malicki, Julian [2 ,3 ,4 ]
Golusinski, Wojciech [5 ,6 ]
机构
[1] Nikolaj Kopernik Mem Reg Specialized Hosp, Dept Med Phys, Lodz, Poland
[2] Greater Poland Canc Ctr, Dept Med Phys, Poznan, Poland
[3] Univ Med Sci, Electroradiol Dept, Poznan, Poland
[4] Adam Mickiewicz Univ, Dept Med Phys, Poznan, Poland
[5] Greater Poland Canc Ctr, Dept Head & Neck Surg, Poznan, Poland
[6] Univ Med Sci, Dept Maxillofacial Surg, Poznan, Poland
关键词
radiotherapy; IMRT; 3D-CRT; head and neck cancer; INTENSITY-MODULATED RADIOTHERAPY; RADIATION-THERAPY; CONVENTIONAL RADIOTHERAPY; CANCER; PARSPORT; ACCURACY; DELIVERY; INDEX; PLANS;
D O I
10.2478/v10019-012-0050-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Treatment planning for head and neck (H&N) cancer is complex due to the number of organs at risk (OAR) located near the planning treatment volume (PTV). Distant OAR must also be taken into consideration. Intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) are both common H&N treatment techniques with very different planning approaches. Although IMRT allows a better dose conformity in PTV, there is much less evidence as to which technique less dose to OAR is delivered. Therefore, the aim of the study was to compare IMRT to 3D-CRT treatment in terms of dose distribution to OAR in H&N cancer. Patients and methods. This was a prospective study of a series of 25 patients diagnosed with stage cT(3-4)N(0-2) laryngeal cancer. All patients underwent total laryngectomy and bilateral selective neck dissections. In all cases, patients were treated with IMRT, although a 3D-CRT treatment plan was also developed for the comparative analysis. To compare doses to specific OAR, we developed a new comparative index based on sub-volumes. Results. In general, IMRT appears to deliver comparable or greater doses to OAR, although the only significant differences were found in the cerebellum, in which-3D-CRT was found to better spare the organ. Conclusions. Organs located outside of the IMRT beam (i.e., distant organs) are generally thought to be well-spared. However, the results of this study show that, in the case of the cerebellum, this was not true. This finding suggests that larger studies should be performed to understand the effects of IMRT on distant tissues. Anthropomorphic phantom studies could also confirm these results.
引用
收藏
页码:328 / 336
页数:9
相关论文
共 36 条
[1]  
[Anonymous], 1993, J ICRU
[2]  
[Anonymous], 1999, PRESCRIBING RECORDIN
[3]  
[Anonymous], 2012, J ICRU, V10
[4]   A fully electronic intensity-modulated radiation therapy quality assurance (IMRT QA) process implemented in a network comprised of independent treatment planning, record and verify, and delivery systems [J].
Bailey, Daniel W. ;
Kumaraswamy, Lalith ;
Podgorsak, Matthew B. .
RADIOLOGY AND ONCOLOGY, 2010, 44 (02) :124-130
[5]   Advances in radiotherapy for head and neck cancer [J].
Bhide, S. A. ;
Nutting, C. M. .
ORAL ONCOLOGY, 2010, 46 (06) :439-441
[6]   Intensity modulated radiotherapy (lMRT) the white, black and grey: a clinical perspective [J].
Bindhu, Joseph ;
Supe, Sanjay ;
Pawar, Yeshwanth .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2009, 14 (03) :95-103
[7]   Novel approaches to improve the therapeutic index of head and neck radiotherapy: An analysis of data from the PARSPORT randomised phase III trial [J].
Buettner, Florian ;
Miah, Aisha B. ;
Gulliford, Sarah L. ;
Hall, Emma ;
Harrington, Kevin J. ;
Webb, Steve ;
Partridge, Mike ;
Nutting, Christopher M. .
RADIOTHERAPY AND ONCOLOGY, 2012, 103 (01) :82-87
[8]   Intensity-modulated radiotherapy increases dose to the brachial plexus compared with conventional radiotherapy for head and neck cancer [J].
Chen, A. M. ;
Hall, W. H. ;
Li, B-Q ;
Guiou, M. ;
Wright, C. ;
Mathai, M. ;
Dublin, A. ;
Purdy, J. A. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997) :58-63
[9]   Pre-trial quality assurance processes for an intensity-modulated radiation therapy (IMRT) trial: PARSPORT, a UK multicentre Phase III trial comparing conventional radiotherapy and parotid-sparing IMRT for locally advanced head and neck cancer [J].
Clark, C. H. ;
Miles, E. A. ;
Urbano, M. T. Guerrero ;
Bhide, S. A. ;
Bidmead, A. M. ;
Harrington, K. J. ;
Nutting, C. M. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (979) :585-594
[10]   Dosimetry audit for a multi-centre IMRT head and neck trial [J].
Clark, Catharine H. ;
Hansen, Vibeke Nordmark ;
Chantler, Hannah ;
Edwards, Craig ;
James, Hayley V. ;
Webster, Gareth ;
Miles, Elizabeth A. ;
Urbano, M. Teresa Guerrero ;
Bhide, Shree A. ;
Bidmead, A. Margaret ;
Nutting, Christoper M. .
RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) :102-108