Automated Data Mining of Lung SBRT Cases for Predicting Dosimetric Indices in Prospective Plans

被引:0
作者
Atwood, T. [1 ]
Xing, L. [1 ]
Hristov, D. [1 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA 94305 USA
关键词
D O I
10.1118/1.4735279
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3753 / 3753
页数:1
相关论文
共 48 条
  • [21] Data mining to evaluate eight years of experience with a multiparametric normalization for lung SBRT
    Tanadini-Lang, Stephanie
    Kuhnis, Anja
    Wilke, Lotte
    Guckenberger, Matthias
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4943 - S4945
  • [22] Dependence of volume dose indices on dose calculation algorithms for VMAT-SBRT plans for peripheral lung tumor
    Matsuoka, Takanori
    Araki, Fujio
    Ohno, Takeshi
    Sakata, Junichi
    Tominaga, Hirofumi
    MEDICAL DOSIMETRY, 2019, 44 (03) : 284 - 290
  • [23] Predicting Dosimetric Impact of Setup Uncertainties in Multi-Isocenter Spine SBRT Using An Automated Dose Accumulation Tool
    Zhang, L.
    Liang, J.
    Mechalakos, J.
    Aristophanous, M.
    Shah, N.
    Hu, Y.
    Zhang, P.
    Cervino, L.
    MEDICAL PHYSICS, 2022, 49 (06) : E337 - E337
  • [24] Analysis of Three QA Methods for Predicting Dose Deviation Pass Percentage for Lung SBRT VMAT Plans
    Hardin, M.
    To, D.
    Giaddui, T.
    Li, J.
    Yu, Y.
    Harrison, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3552 - 3552
  • [25] Comparison of dosimetric effects of MLC positional errors on VMAT and IMRT plans for SBRT radiotherapy in non-small cell lung cancer
    Deng, Jia
    Huang, Yun
    Wu, Xiangyang
    Hong, Ye
    Zhao, Yaolin
    PLOS ONE, 2022, 17 (12):
  • [26] Data mining in RT: Intrafraction motion and treatment time analysis for SBRT lung cancer patients
    Licup, A.
    Nakhaee, S.
    Van Kranen, S.
    Rossi, M.
    Koetsveld, F.
    Sonke, J. J.
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S213 - S214
  • [27] Automated Tools to Facilitate Lung Cancer Outcomes Data-mining
    Lindsay, P. E.
    Dekker, A.
    Sharpe, M. B.
    Giuliani, M. E.
    Purdie, T. G.
    Bezjak, A.
    Hope, A. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S484 - S484
  • [28] Dosimetric Impact of the Use of Jaw Tracking for Fields Smaller Than 3x3 cm(2) in Lung SBRT VMAT Plans
    Hubley, E.
    Scheuermann, R.
    Carlson, D.
    Kennedy, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E757 - E758
  • [29] Use of a second-dose calculation algorithm to check dosimetric parameters for the dose distribution of a first-dose calculation algorithm for lung SBRT plans
    Tsuruta, Yusuke
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Nakata, Manabu
    Ishihara, Yoshitomo
    Mukumoto, Nobutaka
    Akimoto, Mami
    Ono, Tomohiro
    Yano, Shinsuke
    Higashimura, Kyoji
    Matsuo, Yukinori
    Mizowaki, Takashi
    Hiraoka, Masahiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 86 - 95
  • [30] Assessment of MR-Guided Single-Fraction SABR/SBRT of Peripheral Lung Tumors: Dosimetric and Clinical Outcomes - A Prospective Study
    Hering, S.
    Hofmaier, J.
    Marschner, S.
    Schmidt-Hegemann, N-S.
    Mendes, V. da Silva
    Landry, G.
    Niyazi, M.
    Tufman, A.
    Reinmuth, N.
    Belka, C.
    Corradini, S.
    Eze, C.
    JOURNAL OF THORACIC ONCOLOGY, 2024, 19 (10) : S592 - S592