Validation of Geant4 physics models for 56Fe ion beam in various media

被引:5
作者
Jalota, Summit [1 ]
Kumar, Ashavani [1 ]
机构
[1] Natl Inst Technol, Dept Phys, Kurukshetra 136119, Haryana, India
关键词
Monte Carlo simulation; Heavy-ion interaction; Galactic cosmic rays; Shielding; SHIELDING PROPERTIES; GEV/NUCLEON FE-56; FRAGMENTATION; SIMULATION;
D O I
10.1016/j.nimb.2012.08.026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The depth-dose distribution of a Fe-56 ion beam has been studied in water, polyethylene, nextel, kevlar and aluminum media. The dose reduction versus areal depth is also calculated for Fe-56 ions in carbon, polyethylene and aluminum using the Monte Carlo simulation toolkit Geant4. This study presents the validation of physics models available in Geant4 by comparing the simulated results with the experimental data available in the literature. Simulations are performed using binary cascade (BIC), abrasion-ablation (AA) and quantum molecular dynamics (QMD) models; integrated into Geant4. Deviations from experimental results may be due to the selection of simple geometry. This paper also addresses the differences in the simulated results from various models. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 11
页数:5
相关论文
共 30 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[3]  
[Anonymous], 2010, GEANT4 VERS 9 4 PHYS
[4]  
Badhwar GD, 2002, RADIAT RES, V157, P76, DOI 10.1667/0033-7587(2002)157[0076:SRADDI]2.0.CO
[5]  
2
[6]   QMD simulation of expanding nuclear matter [J].
Chikazumi, S ;
Maruyama, T ;
Nitta, K ;
Iwamoto, A .
PHYSICS LETTERS B, 2000, 476 (3-4) :273-278
[7]   Cancer risk from exposure to galactic cosmic rays: implications for space exploration by human beings [J].
Cucinotta, Francis A. ;
Durante, Marco .
LANCET ONCOLOGY, 2006, 7 (05) :431-435
[8]   Biological dosimetry in astronauts [J].
Durante, M .
RIVISTA DEL NUOVO CIMENTO, 1996, 19 (12) :1-44
[9]   Physical basis of radiation protection in space travel [J].
Durante, Marco ;
Cucinotta, Francis A. .
REVIEWS OF MODERN PHYSICS, 2011, 83 (04) :1245-1281
[10]   Fragmentation cross section measurements of iron projectiles using CR-39 plastic nuclear track detectors [J].
Flesch, F ;
Hirzebruch, SE ;
Hüntrup, G ;
Röcher, H ;
Streibel, T ;
Winkel, E ;
Heinrich, W .
RADIATION MEASUREMENTS, 1999, 31 (1-6) :533-536