Problems and Solutions in Laboratory Testing for Hemophilia

被引:35
|
作者
Favaloro, Emmanuel J. [1 ]
Meijer, Piet [2 ]
Jennings, Ian [3 ]
Sioufi, John [4 ]
Bonar, Roslyn A. [4 ]
Kitchen, Dianne P. [2 ]
Kershaw, Geoffrey [5 ]
Lippi, Giuseppe [6 ]
机构
[1] Westmead Hosp, Inst Clin Pathol & Med Res, Dept Haematol, Westmead, NSW 2145, Australia
[2] ECAT Fdn, Voorschoten, Netherlands
[3] NEQAS UK Coagulat, Sheffield, S Yorkshire, England
[4] RCPAQAP Haematol, St Leonards, NSW, Australia
[5] Royal Prince Alfred Hosp, Inst Haematol, Camperdown, NSW 2050, Australia
[6] Acad Hosp Parma, Lab Clin Chem & Hematol, Dept Pathol & Lab Med, Parma, Italy
来源
SEMINARS IN THROMBOSIS AND HEMOSTASIS | 2013年 / 39卷 / 07期
关键词
hemophilia; laboratory testing; preanalytical; analytical; quality; diagnostic practice; VON-WILLEBRAND DISEASE; EXTERNAL QUALITY ASSESSMENT; DIAGNOSTIC HEMOSTASIS LABORATORIES; LARGE MULTICENTER EVALUATION; FACTOR-VIII DEFICIENCY; ACQUIRED HEMOPHILIA; THROMBIN GENERATION; FACTOR INHIBITORS; COAGULATION-FACTORS; PATIENT SAFETY;
D O I
10.1055/s-0033-1356573
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A diagnosis of hemophilia A or hemophilia B begins with clinical assessment of the patient and is facilitated by laboratory testing. The influence of the latter on a diagnosis of hemophilia A or hemophilia B is cleara diagnosis cannot be made without laboratory confirmation of a deficiency of factor FVIII (FVIII) or factor IX (FIX), respectively. Moreover, the degree of hemophilia severity is specifically characterized by laboratory test results. In turn, patient management, including choice and application of therapies, is influenced by the diagnosis, as well as by identification of respective disease severity. An incorrect diagnosis may lead to inappropriate management and unnecessary therapy, and thus to adverse outcomes. Moreover, identification of factor inhibitors in hemophilia will lead to additional and differential treatments, and incorrect identification of inhibitors or inhibitor levels may also lead to inappropriate management. Problems in hemophilia diagnosis or inhibitor detection can occur at any stage in the clinical diagnosis/laboratory interface, from the pre-preanalytical to preanalytical to analytical to postanalytical to post-postanalytical. This report outlines the various problems in laboratory testing for hemophilia and provides various strategies or solutions to overcome these challenges. Although some outlined solutions are specific to the potential errors related to hemophilia, others are general in nature and can be applied to other areas of laboratory hemostasis. Key to improvement in this area is adoption of best practice by all involved, including clinicians, phlebotomists, and laboratories. Also key is the recognition that such errors may occur, and thus that clinicians should assess laboratory test results in the context of their patient's clinical history and follow-up any potential errors, thus avoid misdiagnoses, by requesting repeat testing on a fresh sample.
引用
收藏
页码:816 / 833
页数:18
相关论文
共 50 条
  • [31] Patient Safety and Quality in Laboratory and Hemostasis Testing: A Renewed Loop?
    Plebani, Mario
    Favaloro, Emmanuel J.
    Lippi, Giuseppe
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2012, 38 (06): : 553 - 558
  • [32] Laboratory Testing in Pediatric Rheumatology
    Mehta, Jay
    PEDIATRIC CLINICS OF NORTH AMERICA, 2012, 59 (02) : 263 - +
  • [33] Complement testing in the clinical laboratory
    Willrich, Maria Alice V.
    Braun, Karin M. P.
    Moyer, Ann M.
    Jeffrey, David H.
    Frazer-Abel, Ashley
    CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2021, 58 (07) : 447 - 478
  • [34] Development and Psychometric Testing of the Hemophilia Well-being Index
    Eduardo Remor
    International Journal of Behavioral Medicine, 2013, 20 : 609 - 617
  • [35] Development and Psychometric Testing of the Hemophilia Well-being Index
    Remor, Eduardo
    INTERNATIONAL JOURNAL OF BEHAVIORAL MEDICINE, 2013, 20 (04) : 609 - 617
  • [36] Preanalytic indicators of laboratory performances and quality improvement of laboratory testing
    Lippi, Giuseppe
    Guidi, Gian Cesare
    CLINICAL LABORATORY, 2006, 52 (9-10) : 457 - 462
  • [37] The Views of Hospital Laboratory Workers on Augmenting Laboratory Testing with Robots
    Schadenberg, Bob R.
    Goo, Hideki Garcia
    Nyman, Lena
    Keisu, Jesper
    Evers, Vanessa
    COMPANION OF THE ACM/IEEE INTERNATIONAL CONFERENCE ON HUMAN-ROBOT INTERACTION, HRI 2023, 2023, : 607 - 611
  • [38] ERROR EVALUATION IN THE LABORATORY TESTING PROCESS AND LABORATORY INFORMATION SYSTEMS
    Arifin, Azila
    Yusof, Maryati Mohd
    JOURNAL OF MEDICAL BIOCHEMISTRY, 2022, 41 (01) : 21 - 31
  • [39] HEMOPHILIA CONTROL IN THE LES NATIONS - PROBLEMS AND PRIORITIES - A PERSONAL VIEW
    BHARAT, RA
    HAEMOPHILIA, 1995, 1 (04) : 222 - 226
  • [40] Topical problems in surgical treatment of the locomotor system in patients with hemophilia
    Andreev, YN
    GEMATOLOGIYA I TRANSFUZIOLOGIYA, 2001, 46 (03): : 65 - 74