Catheter ablation of hemodynamically unstable ventricular tachycardia with mechanical circulatory support

被引:28
作者
Lue, Fei [1 ]
Eckman, Peter M. [1 ]
Liao, Kenneth K. [1 ]
Apostolidou, Ioanna [1 ]
John, Ranjit [1 ]
Chen, Taibo [1 ]
Das, Gladwin S. [1 ]
Francis, Gary S. [1 ]
Lei, Han [2 ]
Trohman, Richard G. [3 ]
Benditt, David G. [1 ]
机构
[1] Univ Minnesota, Minneapolis, MN 55455 USA
[2] Chongqing Med Univ, Chongqing, Peoples R China
[3] Rush Univ, Chicago, IL 60612 USA
关键词
Cardiopulmonary bypass; Catheter ablation; Impella; Left ventricular assist device; Mechanical circulatory support; Unstable ventricular tachycardia; MYOCARDIAL-INFARCTION; HEART-FAILURE; ASSIST;
D O I
10.1016/j.ijcard.2013.06.035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Catheter ablation of hemodynamically unstable ventricular tachycardia (VT) is possible with mechanical circulatory support (MCS), little is known regarding the relative safety and efficacy of different supporting devices for such procedures. Methods and results: Sixteen consecutive patients (aged 63 +/- 11 years with left ventricular ejection fraction of 20 +/- 9%) who underwent ablation of hemodynamically unstable VT were included in this study. Hemodynamic support included percutaneous (Impella(R) 2.5, n = 5) and implantable left ventricular assist devices (LVADs, n = 6) and peripheral cardiopulmonary bypass (CPB, n = 5). Except for 2 Impella cases, hemodynamic support was adequate (with consistent mean arterial pressure of >60 mmHg) to permit sufficient activation mapping for ablation. In the Impella and CPB groups, mean time under hemodynamic support was 185 +/- 86 min, and time in VT was 78 +/- 36 min. Clinical VT could be terminated at least once by ablation in all patients except 1 case with Impella due to hemodynamic instability. Peri-procedural complications included hemolysis in 1 patient with Impella and surgical intervention for percutaneous Impella placement problems in another 2. The median number of appropriately delivered defibrillator therapies was significantly decreased from 6 in the month before VT ablation to 0 in the month following ablation (p = 0.001). Conclusions: Our data suggest that peripheral CPB and implantable LVAD provide adequate hemodynamic support for successful ablation of unstable VT. Impella(R) 2.5, on the other hand, was associated with increased risk of complications, and may not provide sufficient hemodynamic support in some cases. (C) 2013 The Authors. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:3859 / 3865
页数:7
相关论文
共 32 条
[1]   Use of the Impella™ Microaxial Blood Pump for Ablation of Hemodynamically Unstable Ventricular Tachycardia [J].
Abuissa, Hussam ;
Roshan, John ;
Lim, Bernard ;
Asirvatham, Samuel J. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (04) :458-461
[2]  
Benditt DG, 2004, CARDIAC ARRHYTHMIAS 2003, P427
[3]   The role of percutaneous left ventricular assist devices during ventricular tachycardia ablation [J].
Bunch, T. Jared ;
Mahapatra, Srijoy ;
Reddy, Yeruva Madhu ;
Lakkireddy, Dhanunjaya .
EUROPACE, 2012, 14 :II26-II32
[4]   Efficacy and safety of ventricular tachycardia ablation with mechanical circulatory support compared with substrate-based ablation techniques [J].
Bunch, T. Jared ;
Darby, Andy ;
May, Heidi T. ;
Ragosta, Michael ;
Lim, D. Scott ;
Taylor, Angela M. ;
DiMarco, John P. ;
Ailawadi, Gorav ;
Revenaugh, James R. ;
Weiss, J. Peter ;
Mahapatra, Srijoy .
EUROPACE, 2012, 14 (05) :709-714
[5]   Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energy - Results of a prospective multicenter study [J].
Calkins, H ;
Epstein, A ;
Packer, D ;
Arria, AM ;
Hummel, J ;
Gilligan, DM ;
Trusso, J ;
Carlson, M ;
Luceri, R ;
Kopelman, H ;
Wilber, D ;
Wharton, JM ;
Stevenson, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (07) :1905-1914
[6]   Electrophysiologic characteristics and catheter ablation of ventricular tachyarrhythmias among patients with heart failure on ventricular assist device support [J].
Cantillon, Daniel J. ;
Bianco, Christopher ;
Wazni, Oussama M. ;
Kanj, Mohamed ;
Smedira, Nicholas G. ;
Wilkoff, Bruce L. ;
Starling, Randall C. ;
Saliba, Walid I. .
HEART RHYTHM, 2012, 9 (06) :859-864
[7]  
Carbucicchio C, 2009, HERZ, V34, P545, DOI 10.1007/s00059-009-3289-3
[8]   Role of contact and noncontact mapping in the curative ablation of tachyarrhythmias [J].
Dixit, S ;
Callans, DJ .
CURRENT OPINION IN CARDIOLOGY, 2002, 17 (01) :65-72
[9]  
Dixon S, 2009, J DEV BEHAV PEDIATR, V30, P2
[10]   Treatment of ventricular tachycardia in patients with heart failure [J].
Fong M.W. ;
Grazette L. ;
Cesario D. ;
Cao M. ;
Saxon L. .
Current Cardiology Reports, 2011, 13 (3) :203-209