Model Predictive Control of a Three-Phase Two-Level Four-Leg Grid-Connected Converter Based on Sphere Decoding Method

被引:22
|
作者
Long, Bo [1 ]
Cao, Tianxu [1 ]
Fang, Wenting [1 ]
Chong, Kil To [2 ]
Guerrero, Josep M. [3 ]
机构
[1] Univ Elect Sci & Technol China, Inst Elect Vehicle Driving Syst & Safety Technol, Sch Mech & Elect Engn, Chengdu 611731, Peoples R China
[2] Jeonbuk Natl Univ, Dept Elect & Informat Engn, Jeonju 54896, South Korea
[3] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
基金
中国国家自然科学基金;
关键词
Switches; Decoding; Predictive models; Voltage control; Bridge circuits; Legged locomotion; Cost function (CF); finite-control-set (FCS) model predictive control; node comparison method; three-phase four-leg grid-connected converter (GCC); POWER CONVERTERS; IMPLEMENTATION; DESIGN; MPC;
D O I
10.1109/TPEL.2020.3006432
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To achieve optimal control of four-leg grid-connected converters in terms of switching frequency and current tracking, the finite-control-set model-predictive-control method (FCS-MPC) can be applied. In this method, the cost function (CF) considers tracking control of grid current, filter capacitance voltage, and converter-side current as well as switching frequency before allocating different weights in its calculations. Thus, multiobjective optimization is achieved by trying to find the optimal switching sequence that minimizes the CF. However, as the horizon length is increased, the solution search enlarges exponentially, soon requiring an exhaustive search through each of many candidates. To alleviate this computational burden, this article presents an FCS-MPC method that is based on a new node-comparison sphere decoding method (NC-SDM), thereby reformulating the CF minimization problem into an integral-least-squares problem. The proposed NC-SDM reduces the computational burden associated with longer horizons by excluding as many suboptimal solutions from the candidates as possible. It does this by continuously comparing the length of two paths corresponding to each node of the search tree, and always taking the branch with shorter length. The final length of the total path is set as the initial radius after superposing all the path lengths. As a result, the initial radius estimation is much smaller than that in the Babai method and the computational cost is further reduced. Finally, simulation and experimental results validate the feasibility and suitability of the proposed method.
引用
收藏
页码:2283 / 2297
页数:15
相关论文
共 50 条
  • [31] Sequential Model Predictive Fault-Tolerance Control for T-Type Three-Level Grid-Connected Converters With LCL Filters
    Long, Bo
    Cao, TianXu
    Sheng, DaWei
    Rodriguez, Jose
    Guerrero, Josep M.
    Chong, Kil To
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (09) : 9039 - 9051
  • [32] Predictive Current Control for Three-Level Four-Leg Indirect Matrix Converter Under Unbalanced Input Voltage
    Basri, Hazrul Mohamed
    Mekhilef, Saad
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (04) : 3738 - 3750
  • [33] Internal Model Based Smooth Transition of a Three-Phase Inverter Between Islanded and Grid-Connected Modes
    Yazdani, Sara
    Ferdowsi, Mehdi
    Shamsi, Pourya
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2020, 35 (01) : 405 - 415
  • [34] Observer-Based State-Space Current Control for a Three-Phase Grid-Connected Converter Equipped With an LCL Filter
    Kukkola, Jarno
    Hinkkanen, Marko
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (04) : 2700 - 2709
  • [35] Observer-Based State-Space Current Control for a Three-Phase Grid-Connected Converter Equipped With an LCL Filter
    Kukkola, Jarno
    Hinkkanen, Marko
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 1371 - 1378
  • [36] Direct-current Vector Control of Three-phase Grid-connected Converter with L, LC, and LCL Filters
    Li, Shuhui
    Jaithwa, Ishan
    Suftah, Raed
    Fu, Xingang
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (14) : 1644 - 1655
  • [37] Improved Control of Three Phase Dual-Stage Grid-Connected PV System Based on a Predictive Control Strategy
    Laib, Abdelbaset
    Krim, Fateh
    Talbi, Billel
    Kihal, Abbes
    Feroura, Liamza
    CONTROL ENGINEERING AND APPLIED INFORMATICS, 2018, 20 (03): : 12 - 23
  • [38] Droop Control of Three- and Four-Leg Hybrid Parallel Inverters Based on Three-Phase Generalized Coordinate Transformation
    Tan, Guangjun
    Zheng, Yixing
    Zhao, Wei
    Qi, Lei
    Sun, Xiaofeng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (12) : 15831 - 15844
  • [39] Predictive Current Control of Three-Phase Grid-Connected Converters With Constant Switching Frequency for Wind Energy Systems
    Song, Zhanfeng
    Xia, Changliang
    Liu, Tao
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (06) : 2451 - 2464
  • [40] Model-Free Predictive Current Control of Three-Level Grid-Connected Inverters With LCL Filters Based on Kalman Filter
    Zhao, Tao
    Zhang, Mingzhou
    Wang, Chunlin
    Sun, Quan
    IEEE ACCESS, 2023, 11 : 21631 - 21640