Identification of vertebral deformities in men: Comparison of morphometric radiography and morphometric X-ray absorptiometry

被引:14
作者
Ferrar, L [1 ]
Eastell, R [1 ]
机构
[1] Univ Sheffield, Bone Metab Grp, Med Sect, Div Clin Sci, Sheffield, S Yorkshire, England
关键词
absorptiometry; deformity; men; reference values; vertebrae;
D O I
10.1007/s001980050212
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Osteoporotic vertebral deformities may be detected by morphometric radiography (MR) using spinal radiographs, and by morphometric X-ray absorptiometry (MXA) using dual-energy X-ray absorptiometry. Reference values for MR may not be appropriate for MXA, and reference values may be affected by gender and age. The aims of this study were to (1) compare mean deformity of vertebral height ratios for MR and MXA in men, (2) compare mean deformity for MXA in men and women, (3) compare mean wedge angle measured by MXA in men and women and (4) assess the effect of aging on MXA values in men. We studied a general practitioner sample of 115 men aged 22-81 years (mean 53 years) and 124 women aged 55-89 years (mean 68 years). Subjects had MXA of T4 to LP, using the Hologic QDR 4500A. Women and men over age 50 years had radiographs of the thoraco-lumbar spine. Scans and radiographs were marked in the same way by one operator and vertebral height ratios and mean deformity were calculated for MR and MXA. The mean wedge angle, theta, was calculated for MXA in all subjects. Mean wedge and biconcavity deformity and standard deviation (SD) in men were greater for MXA than for MR. The mean wedge and biconcavity deformity measured by MXA tended to be greater for men than for women. Vertebral deformity in men increased with age, and was associated with degenerative change seen on spinal radiographs. The mean wedge angle was greater for men than for women, and it increased with age in men. We conclude that sex- and age-specific reference ranges should be established separately for MXA.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [31] Intrarater Reliability of Dual-Energy X-Ray Absorptiometry-Based Measures of Vertebral Height in Postmenopausal Women
    Bonnyman, Alison M.
    Webber, Colin E.
    Stratford, Paul W.
    MacInyre, Norma J.
    JOURNAL OF CLINICAL DENSITOMETRY, 2012, 15 (04) : 405 - 412
  • [32] Upper and lower limbs composition: a comparison between anthropometry and dual-energy X-ray absorptiometry in healthy people
    Diano, Danila
    Ponti, Federico
    Guerri, Sara
    Mercatelli, Daniele
    Amadori, Michele
    Aparisi Gomez, Maria Pilar
    Battista, Giuseppe
    Guglielmi, Giuseppe
    Bazzocchi, Alberto
    ARCHIVES OF OSTEOPOROSIS, 2017, 12 (01)
  • [33] Prevalence of morphometric vertebral fractures in old men and the agreement between different methods in the city of Recife, Brazil
    Borges, Carla Nubia
    de Almeida, Juliana Maia
    Lima, Denise
    Cabral, Marcelo
    Bandeira, Francisco
    RHEUMATOLOGY INTERNATIONAL, 2014, 34 (10) : 1387 - 1394
  • [34] Prevalence of morphometric vertebral fractures in old men and the agreement between different methods in the city of Recife, Brazil
    Carla Nubia Borges
    Juliana Maia de Almeida
    Denise Lima
    Marcelo Cabral
    Francisco Bandeira
    Rheumatology International, 2014, 34 : 1387 - 1394
  • [35] Magnetic resonance imaging and dual energy X-ray absorptiometry of the lumbar spine in professional wrestlers and untrained men
    Hu, M.
    Sheng, J.
    Kang, Z.
    Zou, L.
    Guo, J.
    Sun, P.
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2014, 54 (04) : 505 - 510
  • [36] Dual X-ray Absorptiometry in Today's Clinical Practice
    Dasher, Lance G.
    Newton, Christopher D.
    Lenchik, Leon
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2010, 48 (03) : 541 - +
  • [37] MEASUREMENT OF FOREARM BONE-MINERAL DENSITY BY X-RAY ABSORPTIOMETRY - COMPARISON WITH OTHER SKELETAL SITES
    REY, P
    SORNAYRENDU, E
    GARNERO, P
    VEYMARTY, B
    DELMAS, PD
    REVUE DU RHUMATISME, 1994, 61 (09): : 548 - 554
  • [38] The Effect of the Lumbar Vertebral Malpositioning on one Mineral Density Measurements of the Lumbar Spine by Dual-Energy X-Ray Absorptiometry
    Izadyar, Sina
    Golbarg, Shima
    Takavar, Abbas
    Zakariaee, Seyed Salman
    JOURNAL OF CLINICAL DENSITOMETRY, 2016, 19 (03) : 277 - 281
  • [39] Case finding for sarcopenia in geriatric inpatients: performance of bioimpedance analysis in comparison to dual X-ray absorptiometry
    Reiss, Jens
    Iglseder, Bernhard
    Kreutzer, Martina
    Weilbuchner, Ingrid
    Treschnitzer, Wolfgang
    Kaessmann, Helmut
    Pirich, Christian
    Reiter, Raphael
    BMC GERIATRICS, 2016, 16
  • [40] Lumbar vertebral body compressive strength evaluated by dual-energy X-ray absorptiometry, quantitative computed tomography, and ashing
    Ebbesen, EN
    Thomsen, JS
    Beck-Nielsen, H
    Nepper-Rasmussen, HJ
    Mosekilde, L
    BONE, 1999, 25 (06) : 713 - 724