摘要
A simple and sensitive chemiluminescent (CL) sensing platform for mercury(II) ions (Hg2+) in water was developed based on monolayer molybdenum disulfide (MoS2). The layered MoS2 can catalyze the oxidation of luminol by H2O2, producing an enhanced CL signal because of the peroxidase-like activity of the layered MoS2. In addition, MoS2 has a good adsorption ability to Hg2+ because of the inherent affinity of Hg2+ to sulfur contained in MoS2. Interestingly, the pre-incubation of Hg2+ with layered MoS2 inhibited the catalytic activity of MoS2 on the luminol-H2O2-MoS2 CL reaction, leading to CL quenching. The CL intensity decreased linearly with increasing concentration of Hg2+ from 0.005 - 40 mu M. The limit of detection (LOD) was estimated to be 1 nM. The relative standard deviation (RSD) was found to be 3.71%, indicating good reproducibility. The recoveries of Hg2+ spiked in tap water were from 100.0 to 116.0% with RSD from 2.7 to 5.6%, detected by the standard addition method, and demonstrated good applicability.
引用
收藏
页码:551 / 556
页数:6
相关论文
共 50 条
  • [11] Sensitive detection for coralyne and mercury ions based on homo-A/T DNA by exonuclease signal amplification
    Huang, Hailiang
    Shi, Shuo
    Zheng, Xuyue
    Yao, Tianming
    BIOSENSORS & BIOELECTRONICS, 2015, 71 : 439 - 444
  • [12] Fluorescent sensing of mercury (II) and copper (II) ions based on DNA-templated Cu/Ag nanoclusters
    Huang, Xiu-Fang
    Ren, Bing-Xue
    Peng, Chi-Fang
    Wei, Xin-Lin
    Xie, Zheng-Jun
    MICROCHEMICAL JOURNAL, 2020, 158
  • [13] Selective chemiluminescent sensor for detection of mercury(II) ions using non-aggregated luminol-capped gold nanoparticles
    Li, Qi
    Wang, Jiahua
    He, Yi
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 64 - 69
  • [14] Au NPs-enhanced surface plasmon resonance for sensitive detection of mercury(II) ions
    Wang, Li
    Li, Tao
    Du, Yan
    Chen, Chaogui
    Li, Ling
    Zhou, Ming
    Dong, Shaojun
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (12) : 2622 - 2626
  • [15] Highly Sensitive Electrochemiluminescence Detection of Mercury(II) Ions Based on DNA-Linked Luminol-Au NPs Superstructure
    Wan, Jun
    Yin, Guang
    Ma, Xiuju
    Xing, Ling
    Luo, Xiliang
    ELECTROANALYSIS, 2014, 26 (04) : 823 - 830
  • [16] A HIGHLY SENSITIVE MERCURY (II) ION DETECTION BASED ON NANOFLUIDIC CRYSTAL SENSING
    Wu, Yuanjian
    Gong, Jie
    Jin, Yufeng
    Wang, Wei
    2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 448 - 450
  • [17] Expanding the interlayers of molybdenum disulfide toward the highly sensitive sensing of hydrogen peroxide
    Shu, Yijin
    Zhang, Wenbiao
    Cai, Huaihong
    Yang, Yang
    Yu, Xiang
    Gao, Qingsheng
    NANOSCALE, 2019, 11 (14) : 6644 - 6653
  • [18] Fluorescent sensing and determination of mercury (II) ions in water
    Ncube, Phendukani
    Krause, Rui W. M.
    Ndinteh, Derek T.
    Mamba, Bhekie B.
    WATER SA, 2014, 40 (01) : 175 - 182
  • [19] Thiol terminated chitosan capped silver nanoparticles for sensitive and selective detection of mercury (II) ions in water
    Sharma, Pinki
    Mourya, Mohini
    Choudhary, Deepika
    Goswami, Manoj
    Kundu, Indra
    Dobhal, Mahabeer Prasad
    Tripathi, Chandra Shekhar Pati
    Guin, Debanjan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 268 : 310 - 318
  • [20] A simple and sensitive colorimetric method for detection of mercury ions based on anti- aggregation of gold nanoparticles
    Lou, Tingting
    Chen, Ling
    Zhang, Chunrong
    Kang, Qi
    You, Huiyan
    Shen, Dazhong
    Chen, Lingxin
    ANALYTICAL METHODS, 2012, 4 (02) : 488 - 491