Microtransesophageal Echocardiographic Guidance during Percutaneous Interatrial Septal Closure without General Anaesthesia

被引:5
作者
Snijder, Roel J. R. [1 ]
Renes, Laura E. [2 ]
Swaans, Martin J. [1 ]
Suttorp, Maarten Jan [1 ]
Ten Berg, Jurrien M. [1 ]
Post, Martijn C. [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Emergency Med, Nieuwegein, Netherlands
关键词
PATENT FORAMEN OVALE; TRANSCATHETER CLOSURE; PARADOXICAL EMBOLISM; OCCLUDER DEVICES; SHUNT; INTERVENTIONS; EFFICACY; OUTCOMES; DEFECTS; SAFETY;
D O I
10.1155/2020/1462140
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To study the safety and efficacy of microtransesophageal echocardiography (micro-TEE) and TEE during percutaneous atrial septal defect (ASD) and patent foramen ovale (PFO) closure.Background. TEE has proven to be safe during ASD and PFO closure under general anaesthesia. Micro-TEE makes it possible to perform these procedures under local anaesthesia. We are the first to describe the safety and efficacy of micro-TEE for percutaneous closure.Methods. All consecutive patients who underwent ASD and PFO closure between 2013 and 2018 were included. The periprocedural complications were registered. Residual shunts were diagnosed using transthoracic contrast echocardiography (TTCE). All data were compared between the use of TEE or micro-TEE within the ASD and PFO groups separately.Results. In total, 82 patients underwent ASD closure, 46 patients (49.1 +/- 15.0 years) with TEE and 36 patients (47.8 +/- 12.1 years) using micro-TEE guidance. Median device diameter was, respectively, 26 mm (range 10-40 mm) and 27 mm (range 10-35 mm). PFO closure was performed in 120 patients, 55 patients (48.6 +/- 9.2 years, median device diameter 25 mm, range 23-35 mm) with TEE and 65 patients (mean age 51.0 +/- 11.8 years, median device diameter 27 mm, range 23-35 mm) using micro-TEE. There were no major periprocedural complications, especially no device embolizations within all groups. Six months after closure, there was no significant difference in left-to-right shunt after ASD closure and no significant difference in right-to-left shunt after PFO closure using TEE or micro-TEE.Conclusion. Micro-TEE guidance without general anaesthesia during percutaneous ASD and PFO closure is as safe as TEE, without a significant difference in the residual shunt rate after closure.
引用
收藏
页数:7
相关论文
共 31 条
  • [1] Conscious Sedation Versus General Anesthesia in Transcatheter Aortic Valve Replacement: A Cost and Outcome Analysis
    Ahmad, Mansoor
    Patel, Jay N.
    Vipparthy, Sharath C.
    Divecha, Chirag
    Barzallo, Pablo
    Kim, Minchul
    Schrader, Steven C.
    Barzallo, Marco
    Mungee, Sudhir
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)
  • [2] Intracardiac versus transesophageal echocardiography to guide transcatheter closure of interatrial communications: Nationwide trend and comparative analysis
    Alqahtani, Fahad
    Bhirud, Ashwin
    Aljohani, Sami
    Mills, James
    Kawsara, Akram
    Runkana, Ashok
    Alkhouli, Mohamad
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2017, 30 (03) : 234 - 241
  • [3] Transcatheter Interatrial Septal Defect Closure in a Large Cohort: Midterm Follow-up Results
    Aytemir, Kudret
    Oto, Ali
    Ozkutlu, Suheyla
    Canpolat, Ugur
    Kaya, Ergun Baris
    Yorgun, Hikmet
    Sahiner, Levent
    Sunman, Hamza
    Ates, Ahmet Hakan
    Kabakci, Giray
    [J]. CONGENITAL HEART DISEASE, 2013, 8 (05) : 418 - 427
  • [4] Early-Mid Term Follow-Up Results of Percutaneous Closure of the Interatrial Septal Defects with Occlutech Figulla Devices: A Single Center Experience
    Aytemir, Kudret
    Oto, Ali
    Ozkutlu, Suheyla
    Kaya, Ergun Baris
    Canpolat, Ugur
    Yorgun, Hikmet
    Sahiner, Levent
    Kabakci, Giray
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2012, 25 (04) : 375 - 381
  • [5] Transcatheter closure of patent foramen ovale (PFO) in patients with paradoxical embolism - Periprocedural safety and mid-term follow-up results of three different device occluder systems
    Braun, M
    Gliech, V
    Boscheri, A
    Schoen, S
    Gahn, G
    Reichmann, H
    Haass, M
    Schraeder, R
    Strasser, RH
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 (05) : 424 - 430
  • [6] Cost analysis of injection laryngoplasty performed under local anaesthesia versus general anaesthesia: an Australian perspective
    Chandran, D.
    Woods, C. M.
    Schar, M.
    Ma, N.
    Ooi, E. H.
    Athanasiadis, T.
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2018, 132 (02) : 168 - 172
  • [7] Is local anaesthesia a favourable approach for transcatheter aortic valve implantation? A systematic review and meta-analysis comparing local and general anaesthesia
    Ehret, Constanze
    Rossaint, Rolf
    Foldenauer, Ann Christina
    Stoppe, Christian
    Stevanovic, Ana
    Dohms, Katharina
    Hein, Marc
    Schaelte, Gereon
    [J]. BMJ OPEN, 2017, 7 (09):
  • [8] Comparison of residual shunt rate and complications across 6 different closure devices for patent foramen ovale
    Fleming, Rubine Gevorgyan
    Kumar, Preetham
    West, Brian
    Noureddin, Nabil
    Rusheen, Joshua
    Aboulhosn, Jamil
    Tobis, Jonathan M.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (03) : 365 - 372
  • [9] Frank Lowell H, 2014, World J Pediatr Congenit Heart Surg, V5, P565, DOI 10.1177/2150135114542167
  • [10] Transcatheter closure of atrial septal defect with the Figulla® ASD Occluder: A comparative study with the Amplatzer® Septal Occluder
    Godart, Francois
    Houeijeh, Ali
    Recher, Morgan
    Francart, Charles
    Polge, Anne-Sophie
    Richardson, Marjorie
    Cajot, Marie-Andree
    Duhamel, Alain
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2015, 108 (01) : 57 - 63