Energy matrices evaluation of a conventional and modified partially covered photovoltaic thermal collector

被引:9
作者
Jha, Prabhakar [1 ]
Das, Biplab [2 ,3 ]
Gupta, Rajat [3 ]
机构
[1] Jaypee Inst Informat Technol, Sect 128, Noida 201304, Uttar Pradesh, India
[2] Ulster Univ, Ctr Sustainable Technol, Coleraine, Londonderry, North Ireland
[3] NIT Silchar, Dept Mech Engn, Silchar 788010, Assam, India
关键词
Partially covered photovoltaic collector; Wavy absorber; Exergy energy payback time (EPBT); CO2; mitigation; SOLAR AIR COLLECTOR; LIFE-CYCLE COST; PERFORMANCE ANALYSIS; EXERGY ANALYSIS; CLIMATIC CONDITION; METRICS ANALYSIS; HYBRID; SYSTEM; WATER; MODULES;
D O I
10.1016/j.seta.2022.102610
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Partially covered photovoltaic thermal collector (PVT-C) unit has the capability of generating high thermal energy/exergy and a meaningful electrical energy. This study is aimed to modify the traditional unit of PVT-C to improve energy, exergy, and electrical energy generation capability by replacing a flat absorber plate with a wavy absorber plate. A wavy absorber plate is integrated with the partially covered PVT-C unit (PVT-WPC unit) and compared with the partially covered PVT-C unit having a flat absorber plate (PVT-FPC unit). These two units are compared with the yearly values of overall energy and exergy generation capability at an airflow rate of 0.03 kg/s. This work aims to reveal the viability of the modified unit in terms of energy matrices. The findings reveal that the partially covered PVT-WPC units generate 1%, 10.9%, and 14.9% higher yearly net electrical energy, overall energy, and overall exergy than the partially covered PVT-FPC unit. In terms of yearly overall energy and overall exergy, the partially covered PVT-WPC units have achieved 8.7% and 12.5% lower energy payback time (EPBT) and 10.9% and 14.9% higher CO2 mitigation as compared to the partially covered PVT-FPC unit.
引用
收藏
页数:11
相关论文
共 49 条
[41]   Analytical expression of temperature dependent electrical efficiency of N-PVT water collectors connected in series [J].
Shyam ;
Tiwari, G. N. ;
Al-Helal, I. M. .
SOLAR ENERGY, 2015, 114 :61-76
[42]   Performance analysis of basin type solar stills integrated with N identical photovoltaic thermal (PVT) compound parabolic concentrator (CPC) collectors: A comparative study [J].
Singh, D. B. ;
Tiwari, G. N. .
SOLAR ENERGY, 2017, 142 :144-158
[43]   A detailed thermal-electrical model of three photovoltaic/thermal (PV/T) hybrid air collectors and photovoltaic (PV) module: Comparative study under Algiers climatic conditions [J].
Slimani, Mohamed El Amine ;
Amirat, Madjid ;
Kurucz, Ildiko ;
Bahria, Sofiane ;
Hamidat, Abderrahmane ;
Chaouch, Wafa Braham .
ENERGY CONVERSION AND MANAGEMENT, 2017, 133 :458-476
[44]  
Sun Y., 2014, THESIS COLUMBIA U NE
[45]  
Swapnil Dubey Swapnil Dubey, 2008, Open Environmental Sciences, V2, P15, DOI 10.2174/1876325100802010015
[46]   Energy metrics analysis of hybrid - photovoltaic (PV) modules [J].
Tiwari, Arvind ;
Barnwal, P. ;
Sandhu, G. S. ;
Sodha, M. S. .
APPLIED ENERGY, 2009, 86 (12) :2615-2625
[47]   Energy and exergy analysis of a mixed-mode greenhouse-type solar dryer, integrated with partially covered N-PVT air collector [J].
Tiwari, Sumit ;
Tiwari, G. N. .
ENERGY, 2017, 128 :183-195
[48]   Improved PV/T solar collectors with heat extraction by forced or natural air circulation [J].
Tonui, J. K. ;
Tripanagnostopoulos, Y. .
RENEWABLE ENERGY, 2007, 32 (04) :623-637
[49]  
Zohri M., 2016, INT S CURRENT PROGR, P631