Inversion recovery TrueFISP:: Quantification of T1, T2, and spin density

被引:196
作者
Schmitt, P
Griswold, MA
Jakob, PM
Kotas, M
Gulani, V
Flentje, M
Haase, A
机构
[1] Univ Wurzburg, Inst Phys, Klin & Poliklin Strahlentherapie, D-97074 Wurzburg, Germany
[2] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
T-1; quantification; T-2; measurement; inversion recovery; TrueFISP; steady state free precession; SSFP;
D O I
10.1002/mrm.20058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel procedure is proposed to extract T-1, T-2, and relative spin density from the signal time course sampled with a series of TrueFISP images after spin inversion. Generally, the recovery of the magnetization during continuous TrueFISP imaging can be described in good approximation by a three parameter monoexponential function S(t) = S-stst(1-INV exp(-t/T-1(*)). This apparent relaxation time T-1(*) less than or equal to T-1 depends on the flip angle as well as on both T-1 and T-2. Here, it is shown that the ratio T-1/T-2 can be directly extracted from the inversion factor INV, which describes the relation of the signal value extrapolated to t = 0 and the steady-state signal. Analytical expressions are given for the derivation of T-1, T-2, and relative spin density directly from the fit parameters. Phantom results show excellent agreement with single point reference measurements. In human volunteers T-1, T-2, and spin density maps in agreement with literature values were obtained. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 24 条
  • [1] T1 AND T2 MEASUREMENTS ON A 1.5-T COMMERCIAL MR IMAGER
    BREGER, RK
    RIMM, AA
    FISCHER, ME
    PAPKE, RA
    HAUGHTON, VM
    [J]. RADIOLOGY, 1989, 171 (01) : 273 - 276
  • [2] EVALUATION OF PROTON DENSITY BY MAGNETIC-RESONANCE-IMAGING - PHANTOM EXPERIMENTS AND ANALYSIS OF MULTIPLE COMPONENT PROTON TRANSVERSE RELAXATION
    BRIX, G
    SCHAD, LR
    LORENZ, WJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (01) : 53 - 66
  • [3] THE DIFFUSION SENSITIVITY OF FAST STEADY-STATE FREE PRECESSION IMAGING
    BUXTON, RB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) : 235 - 243
  • [4] Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    Carr, JC
    Simonetti, O
    Bundy, J
    Li, DB
    Pereles, S
    Finn, JP
    [J]. RADIOLOGY, 2001, 219 (03) : 828 - 834
  • [5] DEIMLING M, 1994, P 2 ANN M ISMRM
  • [6] PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR
    FREEMAN, R
    HILL, HDW
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) : 366 - &
  • [7] STEADY-STATE FREE PRECESSION IMAGING IN THE PRESENCE OF MOTION - APPLICATION FOR IMPROVED VISUALIZATION OF THE CEREBROSPINAL-FLUID
    HAACKE, EM
    WIELOPOLSKI, PA
    TKACH, JA
    MODIC, MT
    [J]. RADIOLOGY, 1990, 175 (02) : 545 - 552
  • [8] Haacke EM, 1999, MAGNETIC RESONANCE I
  • [9] Characterization and reduction of the transient response in steady-state MR imaging
    Hargreaves, BA
    Vasanawala, SS
    Pauly, JM
    Nishimura, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) : 149 - 158
  • [10] A fast 3D Look-Locker method for volumetric T1 mapping
    Henderson, E
    McKinnon, G
    Lee, TY
    Rutt, BK
    [J]. MAGNETIC RESONANCE IMAGING, 1999, 17 (08) : 1163 - 1171