Numerical investigation on seismic resilient steel beam-to-column connections with replaceable buckling-restrained fuses

被引:12
作者
Chen, Peng [1 ]
Pan, Jianrong [1 ,2 ]
Hu, Fangxin [1 ,2 ]
Wang, Zhan [1 ,2 ]
机构
[1] South China Univ Technol, Sch Civil Engn & Transportat, Guangzhou 510640, Peoples R China
[2] South China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
Joint; Replaceable; Numerical analysis; Buckling-restrained plate; Seismic resilience; HYSTERETIC DAMPERS; MOMENT CONNECTIONS; CYCLIC BEHAVIOR; PERFORMANCE; JOINTS; DESIGN; FRAMES;
D O I
10.1016/j.jcsr.2022.107598
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The detailed finite element model (FEM) of a new replaceable fuse steel beam-to-column joint proposed previ-ously, where bolted steel plates located between the beam and C-shaped shear tab flanges in the beam splicing region behave as structural fuses to dissipate energy with their buckling controlled by the surrounding flanges, was developed in this paper and subjected to cyclic loading at the beam end. The simulated results matched the test results well in terms of the hysteresis curves (and the corresponding backbone curves) and failure modes. Based on the validated FEM, subsequent parametric studies were carried out to investigate the influences of the fuse plate type and slenderness ratio, and the slip coefficient between the steel plates, on seismic performance of this joint. The parametric analysis indicated that, the joint could accommodate an ultimate story drift angle of 6% without damaging the beam or shear tab flanges by using flat-type (FP) fuse plates, which are recommended over slotted-type (SP) and double-slotted-type (DSP) fuse plates, as the latter both types developed earlier buckling than the former FP-type. Eccentric-type (EP) fuse plates are also suggested, with which the joint equipped sustained an ultimate story drift angle of at least 8%. In addition, the slenderness ratio of FP-type fuse plates is recommended to be controlled within 44 since the fuse plates with higher slenderness ratios introduced damage through buckling to the shear tab flanges at an earlier stage, while the slip coefficient presented no significant impact on the joint seismic performance.
引用
收藏
页数:21
相关论文
共 57 条
[1]  
Americal Institute of Steel Construction (AISC), 2020, 35816 AISC ANSI
[2]  
American Institute of Steel Construction (AISC), 2020, 34120 AISC ANSI
[3]  
[Anonymous], 1992, ATC-24
[4]  
Balut N, 2003, STESSA 2003: BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, P129
[5]   A beam-to-column connection with visco-elastic and hysteretic dampers for seismic damage control [J].
Banisheikholeslami, A. ;
Behnamfar, F. ;
Ghandil, M. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 117 :185-195
[6]   Seismic performance of beam to column connections with T-shaped slit dampers [J].
Bayat, K. ;
Shekastehband, B. .
THIN-WALLED STRUCTURES, 2019, 141 :28-46
[7]   Experimental investigation on earthquake-resilient steel beam-to-column joints with replaceable buckling-restrained fuses [J].
Chen, Peng ;
Pan, Jianrong ;
Hu, Fangxin ;
Wang, Zhan .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
[8]   Dynamic behavior of steel frames with beam flanges shaved around connection [J].
Chen, SJ ;
Chu, JM ;
Chou, ZL .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1997, 42 (01) :49-70
[9]  
Chen Y., 2015, P 8 INT S STEEL STRU, P369
[10]   Numerical study on a fully-prefabricated damage-tolerant beam to column connection for an earthquake-resilient frame [J].
Deng, Kailai ;
Wang, Tao ;
Kurata, Masahiro ;
Zhao, Canhui ;
Wang, Kangkang .
ENGINEERING STRUCTURES, 2018, 159 :320-331