Determining the risks of clinically indicated nonthoracic magnetic resonance imaging at 1.5 T for patients with pacemakers and implantable cardioverter-defibrillators: Rationale and design of the MagnaSafe Registry

被引:44
|
作者
Russo, Robert J. [1 ]
机构
[1] Scripps Clin, La Jolla, CA 92037 USA
关键词
LEAD EXTRACTION; CARDIAC-PACEMAKERS; SAFETY; PROTOCOL; DEVICES; ISSUES; TESLA; MR;
D O I
10.1016/j.ahj.2012.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Until recently, the presence of a permanent pacemaker or an implantable cardioverter-defibrillator has been a relative contraindication for the performance of magnetic resonance imaging (MRI). A number of small studies have shown that MRI can be performed with minimal risk when patients are properly monitored and device programming is modified appropriately for the procedure. However, the risk of performing MRI for patients with implanted cardiac devices has not been sufficiently evaluated to advocate routine clinical use. The aim of the present protocol is to prospectively determine the rate of adverse clinical events and device parameter changes in patients with implanted non-MRI-conditional cardiac devices undergoing clinically indicated nonthoracic MRI at 1.5 T. Methods The MagnaSafe Registry is a multicenter, prospective cohort study of up to 1500 MRI examinations in patients with pacemakers or implantable cardioverter-defibrillators implanted after 2001 who undergo clinically indicated nonthoracic MRI following a specific protocol to ensure that preventable potential adverse events are mitigated. Adverse events and changes in device parameter measurements that may be associated with the imaging procedure will be documented. Results Through August 2012, 701 MRI studies have been performed, representing 47% of the total target enrollment. Conclusions The results of this registry will provide additional documentation of the risk of MRI and will further validate a clinical protocol for screening and the performance of clinically indicated MRI for patients with implanted cardiac devices. (Am Heart J 2013;165:266-72.)
引用
收藏
页码:266 / 272
页数:7
相关论文
共 15 条
  • [1] Determining the Risks of Magnetic Resonance Imaging at 1.5 Tesla for Patients With Pacemakers and Implantable Cardioverter Defibrillators
    Cohen, Jennifer D.
    Costa, Heather S.
    Russo, Robert J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (11) : 1631 - 1636
  • [2] Experiences of magnetic resonance imaging scanning in patients with pacemakers or implantable cardioverter-defibrillators
    Han, Donghoon
    Kang, Si-Hyuck
    Cho, Youngjin
    Oh, Il-Young
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2019, 34 (01) : 99 - +
  • [3] Magnetic Resonance Imaging in Patients With Implantable Cardioverter-Defibrillators and Pacemakers
    Roguin, Ariel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (06) : 556 - 557
  • [4] Magnetic Resonance Imaging at 1.5-T in Patients With Implantable Cardioverter-Defibrillators
    Naehle, Claas P.
    Strach, Katharina
    Thomas, Daniel
    Meyer, Carsten
    Linhart, Markus
    Bitaraf, Sascha
    Litt, Harold
    Schwab, Joerg Otto
    Schild, Hans
    Sommer, Torsten
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (06) : 549 - 555
  • [5] Magnetic resonance imaging in patients with pacemakers and implantable cardioverter-defibrillators: A systematic review
    Martins, R. -P.
    Baruteau, A. -E.
    Treguer, F.
    Cesari, O.
    Carsin-Nicol, B.
    Langella, B.
    Leclercq, C.
    Daubert, J. -C.
    Mabo, P.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2010, 59 (04): : 221 - 228
  • [6] Quantitative Assessment of Artifacts on Cardiac Magnetic Resonance Imaging of Patients With Pacemakers and Implantable Cardioverter-Defibrillators
    Sasaki, Takeshi
    Hansford, Rozann
    Zviman, Menekhem M.
    Kolandaivelu, Aravindan
    Bluemke, David A.
    Berger, Ronald D.
    Calkins, Hugh
    Halperin, Henry R.
    Nazarian, Saman
    CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (06) : 662 - U104
  • [7] Magnetic resonance imaging, pacemakers and implantable cardioverter-defibrillators: current situation and clinical perspective
    Gotte, M. J. W.
    Russel, I. K.
    de Roest, G. J.
    Germans, T.
    Veldkamp, R. F.
    Knaapen, P.
    Allaart, C. P.
    van Rossum, A. C.
    NETHERLANDS HEART JOURNAL, 2010, 18 (01) : 31 - 37
  • [8] Recent innovations in the development of magnetic resonance imaging conditional pacemakers and implantable cardioverter-defibrillators
    Lobodzinski, S. Suave
    CARDIOLOGY JOURNAL, 2012, 19 (01) : 98 - 104
  • [9] Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions
    Mollerus, Michael
    Albin, Glenn
    Lipinski, Margaret
    Lucca, Jill
    EUROPACE, 2010, 12 (07): : 947 - 951
  • [10] Cardiac pacemakers and implantable cardioverter defibrillators:: In vitro magnetic resonance imaging evaluation at 1.5-Tesla
    Shellock, Frank G.
    Fischer, Laura
    Fieno, David S.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (01) : 21 - 31