Hemodynamic assessment of paravalvular aortic regurgitation after TAVI: estimated myocardial supply-demand ratio and cardiovascular mortality

被引:15
作者
Patsalis, Polykarpos C. [1 ]
Konorza, Thomas F. M. [1 ]
Al-Rashid, Fadi [1 ]
Plicht, Bjorn [1 ]
Hildebrandt, Heike A. [1 ]
Wendt, Daniel [2 ]
Thielmann, Matthias [2 ]
Jakob, Heinz G. [2 ]
Eggebrecht, Holger [1 ]
Heusch, Gerd [3 ]
Erbel, Raimund [1 ]
Kahlert, Philipp [1 ]
机构
[1] Univ Duisburg Essen, Essen Univ Hosp, Dept Cardiol, Essen, Germany
[2] Univ Duisburg Essen, Essen Univ Hosp, Dept Thorac & Cardiovasc Surg, Essen, Germany
[3] Univ Duisburg Essen, Essen Univ Hosp, Inst Pathophysiol, Essen, Germany
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2013年 / 304卷 / 07期
关键词
aortic regurgitation; aortic stenosis; transcatheter aortic valve implantation; VALVE IMPLANTATION; TRANSCATHETER; STENOSIS; DETERMINANTS; REPLACEMENT; SOCIETY; IMPACT; DEVICE; RISK;
D O I
10.1152/ajpheart.00807.2012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Patsalis PC, Konorza TF, Al-Rashid F, Plicht B, Hildebrandt HA, Wendt D, Thielmann M, Jakob HG, Eggebrecht H, Heusch G, Erbel R, Kahlert P. Hemodynamic assessment of paravalvular aortic regurgitation after TAVI: estimated myocardial supply-demand ratio and cardiovascular mortality. Am J Physiol Heart Circ Physiol 304: H1023-H1028, 2013. First published January 11, 2013; doi:10.1152/ajpheart.00807.2012.-A relevant (at least moderate) paravalvular regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is found in up to 20% of cases and associated with increased mortality. The ratio of the diastolic over the systolic pressure time integral (DPTI:SPTI) has been proposed to reflect an estimate of myocardial oxygen supply versus demand and the propensity for myocardial ischemia. We have now evaluated the potential of this ratio to predict PAR-associated cardiovascular mortality after TAVI, retrospectively analyzing data from 167 consecutive TAVI patients. PAR was graded angiographically, and the myocardial supply-demand ratio was estimated from the planimetric integration of the diastolic and systolic pressure-time area (DPTI and SPTI), respectively. PAR was observed in 113 patients (67%) and angiographically graded as mild in 89 (78.8%), moderate in 21 (18.6%) or moderate to severe in 3 (2.7%) cases. The DPTI:SPTI ratio decreased with increasing Sellers grade of PAR (P < 0.001). A DPTI:SPTI of <= 0.7 predicted cardiovascular mortality (area under the curve = 0.96). Cardiovascular mortality at 30 days and 1 yr was increased in patients with DPTI:SPTI <= 0.7 over those with DPTI:SPTI > 0.7 (42 vs. 2% and 63 vs. 3%, respectively; P < 0.001). In conclusion, DPTI:SPTI provides an excellent cutoff value of <= 0.7 for the prediction of PAR-associated mortality.
引用
收藏
页码:H1023 / H1028
页数:6
相关论文
共 27 条
[1]   Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry [J].
Abdel-Wahab, Mohamed ;
Zahn, Ralf ;
Horack, Martin ;
Gerckens, Ulrich ;
Schuler, Gerhard ;
Sievert, Horst ;
Eggebrecht, Holger ;
Senges, Jochen ;
Richardt, Gert .
HEART, 2011, 97 (11) :899-906
[2]   ISCHEMIC RESPONSE TO SUDDEN STRENUOUS EXERCISE IN HEALTHY MEN [J].
BARNARD, RJ ;
MACALPIN, R ;
KATTUS, AA ;
BUCKBERG, GD .
CIRCULATION, 1973, 48 (05) :936-942
[3]   Transfemoral aortic valve implantation under sedation and monitored anaesthetic care - a feasibility study [J].
Bergmann, L. ;
Kahlert, P. ;
Eggebrecht, H. ;
Frey, U. ;
Peters, J. ;
Kottenberg, E. .
ANAESTHESIA, 2011, 66 (11) :977-982
[4]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[5]   Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence [J].
Detaint, Delphine ;
Lepage, Laurent ;
Himbert, Dominique ;
Brochet, Eric ;
Messika-Zeitoun, David ;
Iung, Bernard ;
Vahanian, Alec .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :821-827
[6]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76
[7]   Heart rate in the pathophysiology of coronary blood flow and myocardial ischaemia: benefit from selective bradycardic agents [J].
Heusch, G. .
BRITISH JOURNAL OF PHARMACOLOGY, 2008, 153 (08) :1589-1601
[8]   MYOCARDIAL SUPPLY/DEMAND RATIO - CRITICAL-REVIEW [J].
HOFFMAN, JIE ;
BUCKBERG, GD .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (02) :327-332
[9]   DETERMINANTS AND PREDICTION OF TRANSMURAL MYOCARDIAL PERFUSION [J].
HOFFMAN, JIE .
CIRCULATION, 1978, 58 (03) :381-391
[10]  
Jakob H, 2012, EUROINTERVENTION