A non-invasive method for the detection of glucose in human exhaled breath by condensation collection coupled with ion chromatography

被引:8
|
作者
Zhou, Yang-Ye [1 ]
Chen, Jia-Ping [2 ]
Gan, Lu [2 ]
Xu, Wen [2 ]
Liu, Yu [3 ]
Zhao, Yong-Gang [4 ]
Zhu, Yan [1 ,5 ]
机构
[1] Zhejiang Univ, Dept Chem, Xixi Campus, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Zhejiang Univ Hosp, Hangzhou 310027, Peoples R China
[3] Zhejiang Univ, Coll Life Sci, Hangzhou 310058, Peoples R China
[4] Zhejiang Shuren Univ, Coll Biol & Environm Engn, Hangzhou 310015, Peoples R China
[5] Zhejiang Univ, Key Lab Hlth Risk Appraisal Trace Tox Chem Zhejian, Hangzhou 310028, Zhejiang, Peoples R China
关键词
Human exhaled breath condensate (EBC); Glucose; Ion chromatography; Pulsed amperometric detection; Diabetes mellitus; CDTE QUANTUM DOTS;
D O I
10.1016/j.chroma.2022.463564
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical method for the detection of glucose in human exhaled breath by non-invasive condensation collection coupled with ion chromatography was developed. A self-designed exhaled breath condensation device was constructed, through which human exhaled breath was condensed and collected. And the glucose in collected human exhaled breath condensate (EBC) was analyzed by ion chromatography with a pulsed amperometric instrument. The standard EBC collection method was established, and the key factors such as cooling temperature and sampling flow rate during condensation collection were investigated deeply, and a good linear correlation between blood glucose levels and exhaled breath glucose levels was obtained. The intra-day precision was 3.37%, and the inter-day precision was 3.83%. Furthermore, EBC from healthy people and diabetic patients was collected in fasting state and after meal. We found the breath glucose level in healthy volunteers was 0.11-2.34 ng/L and that in diabetic patients was 0.23-135.92 ng/L. In after meal samples, the breath glucose level is 10-100 times higher than that of healthy subjects, which offering the prospect of a non-invasive approach to the monitoring of diabetes.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Selective Collection and Condensation of Exhaled Breath for Glucose Detection
    Tankasala, Divya
    Ng, Gabriel P.
    Smith, Michael S.
    Bendell, Jessica R.
    Linnes, Jacqueline C.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3890 - 3893
  • [2] Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler
    Zamuruyev, Konstantin O.
    Aksenov, Alexander A.
    Pasamontes, Alberto
    Brown, Joshua F.
    Pettit, Dayna R.
    Foutouhi, Soraya
    Weimer, Bart C.
    Schivo, Michael
    Kenyon, Nicholas J.
    Delplanque, Jean-Pierre
    Davis, Cristina E.
    JOURNAL OF BREATH RESEARCH, 2017, 11 (01)
  • [3] Non-invasive detection of Aspergillosis in ventilated patients: Galactomannan analysis in exhaled breath
    Tang, XiaoHong
    Yang, Lei
    Zhang, Rong
    Fang, Hong
    Tang, Huan
    Xie, Qian
    Wang, HaiLian
    Chen, Lin
    Yang, Yang
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 110 (01)
  • [4] Non-invasive exhaled breath diagnostic and monitoring technologies
    Ma, Pengze
    Li, Jiaqi
    Chen, Yongxing
    Zhou Montano, Baiyang Antonio
    Luo, Huijian
    Zhang, Di
    Zheng, Huadan
    Liu, Yihua
    Lin, Haoyang
    Zhu, Wenguo
    Zhang, Guanfeng
    Mao, Hua
    Yu, Jianhui
    Chen, Zhe
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (05) : 1475 - 1488
  • [5] Non-Invasive Method for Tuberculosis Exhaled Breath Classification Using Electronic Nose
    Hendrick, Hendrick
    Hidayat, Rahmat
    Horng, Gwo-Jiun
    Wang, Zhi-Hao
    IEEE SENSORS JOURNAL, 2021, 21 (09) : 11184 - 11191
  • [6] A Review of Biosensors for Non-Invasive Diabetes Monitoring and Screening in Human Exhaled Breath
    Usman, Fahad
    Dennis, J. O.
    Ahmed, A. Y.
    Meriaudeau, Fabrice
    Ayodele, O. B.
    Rabih, Almur A. S.
    IEEE ACCESS, 2019, 7 : 5963 - 5974
  • [7] Detection of exhaled volatile organic compounds in breath may offer a non-invasive alternative to capillary blood glucose testing
    Walton, Christopher
    Turner, Claire
    Hoashi, Shu
    Tan, Chong Yew
    Swamy, Ashwini
    Markkula, Pauliina
    Parekh, Bhavin
    Evans, Mark L.
    DIABETES, 2008, 57 : A14 - A14
  • [8] Early non-invasive detection of breast cancer using exhaled breath and urine analysis
    Herman-Saffar, Or
    Boger, Zvi
    Libson, Shai
    Lieberman, David
    Gonen, Raphael
    Zeiri, Yehuda
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 96 : 227 - 232
  • [9] Non-invasive detection of orthotopic human lung tumors by microRNA expression profiling of mouse exhaled breath condensates and exhaled extracellular vesicles
    Mitchell, Megan I.
    Ben-Dov, Iddo Z.
    Liu, Christina
    Wang, Tao
    Hazan, Rachel B.
    Bauer, Thomas L.
    Zakrzewski, Johannes
    Donnelly, Kathryn
    Chow, Kar
    Ma, Junfeng
    Loudig, Olivier
    EXTRACELLULAR VESICLES AND CIRCULATING NUCLEIC ACIDS, 2024, 5 (01): : 138 - 164
  • [10] Non-invasive biomarker sampling and analysis of the exhaled breath proteome
    Bloemen, Karolien
    Hooyberghs, Jef
    Desager, Kristine
    Witters, Erwin
    Schoeters, Greet
    PROTEOMICS CLINICAL APPLICATIONS, 2009, 3 (04) : 498 - 504