Development of Gamma-Ray Transition-Edge-Sensor Microcalorimeters on Thick Membranes

被引:5
|
作者
Iyomoto, Naoko [1 ]
Yoshimine, Ikumi [1 ]
Shuto, Yuki [1 ]
Kuroiwa, Takehiro [1 ]
Maehata, Keisuke [1 ]
Hayashi, Tasuku [2 ]
Muramatsu, Haruka [2 ]
Nagayoshi, Kenichiro [2 ]
Mitsuda, Kazuhisa [2 ]
Takano, Akira [1 ]
Yoshimoto, Shota [1 ]
Kurume, Yuta [1 ]
Ishibashi, Kenji [1 ]
机构
[1] Kyushu Univ, Nishi Ku, 744,Motooka, Fukuoka, Fukuoka 8190395, Japan
[2] ISAS JAXA, Tyuo Ku, 3-1-1,Yoshinodai, Sagamihara, Kanagawa 2525210, Japan
关键词
Gamma-ray; Transition-edge-sensor; Microcalorimeter; Spectroscopy;
D O I
10.1007/s10909-018-2100-3
中图分类号
O59 [应用物理学];
学科分类号
摘要
We developed transition-edge-sensor microcalorimeters to detect gamma rays of energy up to a few MeV. To develop devices that have mechanical robustness and fast response together with reasonable thermal isolation, we fabricated devices with thick (17 mu m or 9.5 mu m) membranes using silicon-on-insulator wafers. Here, we report the results for one of each device. The thermal conductances of the 17-mu m-thick-membrane device and the 9.5-mu m-thick-membrane device were measured to be 84 nW/K and 52 nW/K at their transition temperatures of 162 mK and 202 mK, respectively. The thermal conductances are 20-30 times and 6-9 times larger than those of our thin-membrane devices, when compared at the same temperatures. We irradiated the devices with gamma rays from a Cs-137 source. About 30% of the accumulated pulses are signals from the absorbers, while the remaining are signals from the silicon substrates. The energy resolution of the 662-keV photo peak for the 17-mu m-thick-membrane device is 2.2 keV, whereas the baseline energy resolution is 2.3 keV. The energy resolution is several times worse than the design value. One reason for the degradation of the energy resolution is the low-frequency noise of the mechanical cooler, and the other reason is the thermal noise arising from the Compton-scattering events in the substrate.
引用
收藏
页码:412 / 417
页数:6
相关论文
共 50 条
  • [1] Development of Gamma-Ray Transition-Edge-Sensor Microcalorimeters on Thick Membranes
    Naoko Iyomoto
    Ikumi Yoshimine
    Yuki Shuto
    Takehiro Kuroiwa
    Keisuke Maehata
    Tasuku Hayashi
    Haruka Muramatsu
    Kenichiro Nagayoshi
    Kazuhisa Mitsuda
    Akira Takano
    Shota Yoshimoto
    Yuta Kurume
    Kenji Ishibashi
    Journal of Low Temperature Physics, 2019, 194 : 412 - 417
  • [2] Development of Gamma-Ray Position-Sensitive Transition-Edge-Sensor Microcalorimeters
    Iyomoto, Naoko
    Asagawa, Shinya
    Tsuruta, Tetsuya
    Nishida, Yoshiki
    Hamamura, Yukino
    Kurume, Yuta
    Maehata, Keisuke
    Hayashi, Tasuku
    Mitsuda, Kazuhisa
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (05)
  • [3] Development of Gamma-Ray Position-Sensitive Transition-Edge Sensor Microcalorimeters
    Iyomoto, N.
    Kurume, Y.
    Kuroiwa, T.
    Asagawa, S.
    Tsuruta, T.
    Nishida, Y.
    Hamamura, Y.
    Maehata, K.
    Hayashi, T.
    Muramatsu, H.
    Mitsuda, K.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 200 (5-6) : 233 - 238
  • [4] Development of Gamma-Ray Position-Sensitive Transition-Edge Sensor Microcalorimeters
    N. Iyomoto
    Y. Kurume
    T. Kuroiwa
    S. Asagawa
    T. Tsuruta
    Y. Nishida
    Y. Hamamura
    K. Maehata
    T. Hayashi
    H. Muramatsu
    K. Mitsuda
    Journal of Low Temperature Physics, 2020, 200 : 233 - 238
  • [5] Gamma-Ray Transition-Edge Sensor Microcalorimeters on Solid Substrates
    Naoko Iyomoto
    Hisao Kawakami
    Keisuke Maehata
    Ikumi Yoshimine
    Yuki Shuto
    Kenichiro Nagayoshi
    Kazuhisa Mitsuda
    Shohei Ezaki
    Akira Takano
    Shota Yoshimoto
    Kenji Ishibashi
    Journal of Low Temperature Physics, 2016, 184 : 82 - 87
  • [6] Gamma-Ray Transition-Edge Sensor Microcalorimeters on Solid Substrates
    Iyomoto, Naoko
    Kawakami, Hisao
    Maehata, Keisuke
    Yoshimine, Ikumi
    Shuto, Yuki
    Nagayoshi, Kenichiro
    Mitsuda, Kazuhisa
    Ezaki, Shohei
    Takano, Akira
    Yoshimoto, Shota
    Ishibashi, Kenji
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2016, 184 (1-2) : 82 - 87
  • [7] Characterization of Signal Response of Lead Absorber Coupled Transition Edge Sensor Gamma-Ray Microcalorimeters
    Damayanthi, R. M. Thushara
    Ohno, M.
    Iyomoto, N.
    Takahashi, H.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 211 - 214
  • [8] Optimal filtering, record length, and count rate in transition-edge-sensor microcalorimeters
    Doriese, W. B.
    Adams, J. S.
    Hilton, G. C.
    Irwin, K. D.
    Kilbourne, C. A.
    Schima, F. J.
    Ullom, J. N.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 450 - +
  • [9] High-Resolution Kaonic-Atom X-ray Spectroscopy with Transition-Edge-Sensor Microcalorimeters
    S. Okada
    D. A. Bennett
    W. B. Doriese
    J. W. Fowler
    K. D. Irwin
    S. Ishimoto
    M. Sato
    D. R. Schmidt
    D. S. Swetz
    H. Tatsuno
    J. N. Ullom
    S. Yamada
    Journal of Low Temperature Physics, 2014, 176 : 1015 - 1021
  • [10] High-Resolution Kaonic-Atom X-ray Spectroscopy with Transition-Edge-Sensor Microcalorimeters
    Okada, S.
    Bennett, D. A.
    Doriese, W. B.
    Fowler, J. W.
    Irwin, K. D.
    Ishimoto, S.
    Sato, M.
    Schmidt, D. R.
    Swetz, D. S.
    Tatsuno, H.
    Ullom, J. N.
    Yamada, S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (5-6) : 1015 - 1021