Primary Stability/Mobility of 1-Stage and 2-Stage Dental Implants: A Comparative In Vitro Study

被引:4
|
作者
Gulay, Gulsah [2 ]
Asar, Neset Volkan [3 ]
Tulunoglu, Ibrahim [4 ]
Turkyilmaz, Ilser [5 ]
Wang, Hom-Lay [6 ]
Tozum, Tolga F. [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Periodontol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[3] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[4] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[5] Univ Texas Hlth Sci Ctr San Antonio, Dent Sch Implant Clin, Dept Comprehens Dent, San Antonio, TX 78229 USA
[6] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
关键词
dental implants; transducers; alveolar bone loss; stability; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; MANDIBULAR OVERDENTURES; INITIAL STABILITY; FOLLOW-UP; SYSTEMS; MULTICENTER; CAPACITY; DEFECTS;
D O I
10.1097/ID.0b013e3182661615
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the primary stability of 1-stage (nonsubmerged) and 2-stage (submerged) implants via newest wireless resonance frequency (RF) analyzer and newer wireless mobility measuring (MM) device. Materials and Methods: Six 1-stage dental implants with internal hex connection and six 2-stage dental implants, 4.1 mm in diameter and 11.5 mm in length, were inserted bilaterally into the first premolar, second premolar, and first molar regions of 6 standard mandibular transparent self-curing acrylic resin models. After that, the periimplant circular bone defects were created in millimeter increments ranging between 0 and 5 mm to the same extent on all implants. Results: Implant stability quotient values significantly decreased at 1-stage and 2-stage implants when periimplant defects increased. Similar implant stability quotient values were found for both implant types; however, significantly lower MM values were noted for 2-stage implants. Irrespective of implant systems, the results indicated a significant association between wireless RF analyzer and wireless MM device. Conclusion: Both wireless RF analyzer and wireless MM device were adequate in assessing implant stability. There was no difference between 2-stage and 1-stage implant systems, except lower MM values were noted for nonsubmerged implants. (Implant Dent 2012;21:461-466)
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [41] Influence of placement depth and abutment connection pattern on bone remodeling around 1-stage implants: a prospective randomized controlled clinical trial
    Palaska, Iro
    Tsaousoglou, Phoebus
    Vouros, Ioannis
    Konstantinidis, Antonis
    Menexes, George
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : E47 - E56
  • [42] Parallel screw cylinder implants: Comparative analysis between immediate loading and two-stage healing of 1005 dental implants with a 2-year follow up
    Degidi, Marco
    Piattelli, Adriano
    Carinci, Francesco
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2006, 8 (03) : 151 - 160
  • [43] Insertion Torque (IT) and Implant Stability Quotient (ISQ) Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study
    Mello, Bruno Freitas
    Formiga, Marcio De Carvalho
    Bianchini, Marco Aurelio
    Borges Jr, Ivan
    Coura, Gustavo
    Tumedei, Margherita
    Fuller, Renato
    Petrini, Morena
    Romasco, Tea
    Vaz, Paula
    Piattelli, Adriano
    Di Pietro, Natalia
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [44] Optimizing the primary stability of dental implants in type IV bone: in-vitro comparison of machine-driven and ratcheting insertion protocols
    Taysi, Nuri Mert
    Taysi, Aysegul Erten
    Ercal, Pinar
    Sismanoglu, Soner
    EUROPEAN ORAL RESEARCH, 2025, 59 (01) : 46 - 52
  • [45] Primary stability and osseointegration of dental implants in polylactide modified bone - A pilot study in Goettingen minipigs
    Brockmeyer, Phillipp
    Krohn, Sebastian
    Thiemann, Charlotte
    Schulz, Xenia
    Kauffmann, Philipp
    Troeltzsch, Markus
    Schlottig, Falk
    Schliephake, Henning
    Gruber, Rudolf Matthias
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (08) : 1095 - 1103
  • [46] Influence of Stepped Osteotomy on Primary Stability of Implants Inserted in Low-Density Bone Sites: An In Vitro Study
    Degidi, Marco
    Daprile, Giuseppe
    Piattelli, Adriano
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 37 - 41
  • [47] Implants and sinus-inlay bone grafts in a 1-stage procedure on severely atrophied maxillae:: Surgical aspects of a 3-year follow-up study
    Johansson, B
    Wannfors, K
    Ekenbäck, J
    Smedberg, JI
    Hirsch, J
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (06) : 811 - 818
  • [48] Numerical study on 2-stage phase change heat sink for cooling of photovoltaic panel
    Ding, Yu
    Klemes, Jiri Jaromir
    Zhao, Pengbo
    Zeng, Min
    Wang, Qiuwang
    ENERGY, 2022, 249
  • [49] Can Bone Compaction Improve Primary Implant Stability? An In Vitro Comparative Study with Osseodensification Technique
    Antonelli, Alessandro
    Bennardo, Francesco
    Brancaccio, Ylenia
    Barone, Selene
    Femiano, Felice
    Nucci, Ludovica
    Minervini, Giuseppe
    Fortunato, Leonzio
    Attanasio, Ferdinando
    Giudice, Amerigo
    APPLIED SCIENCES-BASEL, 2020, 10 (23): : 1 - 13
  • [50] Clinical and radiological outcomes of 1-versus 2-stage implant placement: 1-year results of a randomised clinical trial
    Tallarico, Marco
    Vaccarella, Anna
    Marzi, Gian Carlo
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2011, 4 (01) : 13 - 20