Primary Stability/Mobility of 1-Stage and 2-Stage Dental Implants: A Comparative In Vitro Study

被引:4
|
作者
Gulay, Gulsah [2 ]
Asar, Neset Volkan [3 ]
Tulunoglu, Ibrahim [4 ]
Turkyilmaz, Ilser [5 ]
Wang, Hom-Lay [6 ]
Tozum, Tolga F. [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Periodontol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[3] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[4] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[5] Univ Texas Hlth Sci Ctr San Antonio, Dent Sch Implant Clin, Dept Comprehens Dent, San Antonio, TX 78229 USA
[6] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
关键词
dental implants; transducers; alveolar bone loss; stability; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; MANDIBULAR OVERDENTURES; INITIAL STABILITY; FOLLOW-UP; SYSTEMS; MULTICENTER; CAPACITY; DEFECTS;
D O I
10.1097/ID.0b013e3182661615
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the primary stability of 1-stage (nonsubmerged) and 2-stage (submerged) implants via newest wireless resonance frequency (RF) analyzer and newer wireless mobility measuring (MM) device. Materials and Methods: Six 1-stage dental implants with internal hex connection and six 2-stage dental implants, 4.1 mm in diameter and 11.5 mm in length, were inserted bilaterally into the first premolar, second premolar, and first molar regions of 6 standard mandibular transparent self-curing acrylic resin models. After that, the periimplant circular bone defects were created in millimeter increments ranging between 0 and 5 mm to the same extent on all implants. Results: Implant stability quotient values significantly decreased at 1-stage and 2-stage implants when periimplant defects increased. Similar implant stability quotient values were found for both implant types; however, significantly lower MM values were noted for 2-stage implants. Irrespective of implant systems, the results indicated a significant association between wireless RF analyzer and wireless MM device. Conclusion: Both wireless RF analyzer and wireless MM device were adequate in assessing implant stability. There was no difference between 2-stage and 1-stage implant systems, except lower MM values were noted for nonsubmerged implants. (Implant Dent 2012;21:461-466)
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [1] Retrospective cohort study of the clinical performance of 1-stage dental implants
    Carr, AB
    Choi, YG
    Eckert, SE
    Desjardins, RP
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 399 - 405
  • [2] Are marginal bone levels and implant stability/mobility affected by single-stage platform switched dental implants? A comparative clinical study
    Dursun, Erhan
    Tulunoglu, Ibrahim
    Canpinar, Pinar
    Uysal, Serdar
    Akalin, Ferda Alev
    Tozum, Tolga F.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1161 - 1167
  • [3] Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: A pilot study
    Zix, J
    Kessler-Liechti, G
    Mericske-Stern, D
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (05) : 747 - 752
  • [4] Which device is more accurate to determine the stability/mobility of dental implants? A human cadaver study
    Tozum, T. F.
    Bal, B. T.
    Turkyilmaz, I.
    Gulay, G.
    Tulunoglu, I.
    JOURNAL OF ORAL REHABILITATION, 2010, 37 (03) : 217 - 224
  • [5] Analysis of Short Implants and Lateralization of the Inferior Alveolar Nerve With 2-Stage Dental Implants by Finite Element Method
    Amorim Vasco, Marco Antonio
    Hecke, Mildred Ballin
    Bezzon, Osvaldo Luiz
    JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (06) : 2064 - 2071
  • [6] Stability measurements of 1-stage implants in the edentulous mandible by means of resonance frequency analysis
    Kessler-Liechti, Gerda
    Zix, Juergen
    Mericske-Stern, Regina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (02) : 353 - 358
  • [7] Microleakage into and from Two-Stage Implants: An In Vitro Comparative Study
    Teixeira, Wendel
    Ribeiro, Ricardo Faria
    Sato, Sandra
    Pedrazzi, Vinicius
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) : 56 - 62
  • [8] In vitro analysis of the influence of surface treatment of dental implants on primary stability
    Mazzo, Carla Rodrigues
    dos Reis, Andrea Candido
    Shimano, Antonio Carlos
    da Costa Valente, Mariana Lima
    BRAZILIAN ORAL RESEARCH, 2012, 26 (04) : 313 - 317
  • [9] The Effect of Increasing Thread Depth on the Initial Stability of Dental Implants: An In Vitro Study
    Cucinelli, Chiara
    Pereira, Miguel Silva
    Borges, Tiago
    Figueiredo, Rui
    Leitao-Almeida, Bruno
    SURGERIES, 2024, 5 (03): : 817 - 825
  • [10] 1-stage versus 2-stage lateral sinus lift procedures: 1-year post-loading results of a multicentre randomised controlled trial
    Felice, Pietro
    Pistilli, Roberto
    Piattelli, Maurizio
    Soardi, Elisa
    Barausse, Carlo
    Corvino, Valeria
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (01) : 65 - 75