Targeted Selected Reaction Monitoring Mass Spectrometric Immunoassay for Insulin-like Growth Factor 1

被引:38
作者
Niederkofler, Eric E. [1 ]
Phillips, David A. [1 ]
Krastins, Bryan [2 ]
Kulasingam, Vathany [3 ,4 ]
Kiernan, Urban A. [1 ]
Tubbs, Kemmons A. [1 ]
Peterman, Scott M. [2 ]
Prakash, Amol [2 ]
Diamandis, Eleftherios P. [3 ,4 ]
Lopez, Mary F. [2 ]
Nedelkov, Dobrin [1 ]
机构
[1] Thermo Fisher Sci, Tempe, AZ USA
[2] Thermo Fisher Sci, BRIMS, Cambridge, MA USA
[3] Univ Hlth Network, Toronto, ON, Canada
[4] Univ Toronto, Toronto, ON, Canada
来源
PLOS ONE | 2013年 / 8卷 / 11期
关键词
IGF-I ASSAYS; HORMONE ABUSE; QUANTIFICATION; PLASMA; RADIOIMMUNOASSAY; REPRODUCIBILITY; EXTRACTION; BIOMARKERS; PROTEINS; PEPTIDE;
D O I
10.1371/journal.pone.0081125
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Insulin-like growth factor 1 (IGF1) is an important biomarker of human growth disorders that is routinely analyzed in clinical laboratories. Mass spectrometry-based workflows offer a viable alternative to standard IGF1 immunoassays, which utilize various pre-analytical preparation strategies. In this work we developed an assay that incorporates a novel sample preparation method for dissociating IGF1 from its binding proteins. The workflow also includes an immunoaffinity step using antibody-derivatized pipette tips, followed by elution, trypsin digestion, and LC-MS/MS separation and detection of the signature peptides in a selected reaction monitoring (SRM) mode. The resulting quantitative mass spectrometric immunoassay (MSIA) exhibited good linearity in the range of 1 to 1,500 ng/mL IGF1, intra-and inter-assay precision with CVs of less than 10%, and lowest limits of detection of 1 ng/mL. The linearity and recovery characteristics of the assay were also established, and the new method compared to a commercially available immunoassay using a large cohort of human serum samples. The IGF1 SRM MSIA is well suited for use in clinical laboratories.
引用
收藏
页数:6
相关论文
共 37 条
  • [1] Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma
    Addona, Terri A.
    Abbatiello, Susan E.
    Schilling, Birgit
    Skates, Steven J.
    Mani, D. R.
    Bunk, David M.
    Spiegelman, Clifford H.
    Zimmerman, Lisa J.
    Ham, Amy-Joan L.
    Keshishian, Hasmik
    Hall, Steven C.
    Allen, Simon
    Blackman, Ronald K.
    Borchers, Christoph H.
    Buck, Charles
    Cardasis, Helene L.
    Cusack, Michael P.
    Dodder, Nathan G.
    Gibson, Bradford W.
    Held, Jason M.
    Hiltke, Tara
    Jackson, Angela
    Johansen, Eric B.
    Kinsinger, Christopher R.
    Li, Jing
    Mesri, Mehdi
    Neubert, Thomas A.
    Niles, Richard K.
    Pulsipher, Trenton C.
    Ransohoff, David
    Rodriguez, Henry
    Rudnick, Paul A.
    Smith, Derek
    Tabb, David L.
    Tegeler, Tony J.
    Variyath, Asokan M.
    Vega-Montoto, Lorenzo J.
    Wahlander, Asa
    Waldemarson, Sofia
    Wang, Mu
    Whiteaker, Jeffrey R.
    Zhao, Lei
    Anderson, N. Leigh
    Fisher, Susan J.
    Liebler, Daniel C.
    Paulovich, Amanda G.
    Regnier, Fred E.
    Tempst, Paul
    Carr, Steven A.
    [J]. NATURE BIOTECHNOLOGY, 2009, 27 (07) : 633 - U85
  • [2] COMPARISON OF ACID ETHANOL EXTRACTION AND ACID GEL-FILTRATION PRIOR TO IGF-I AND IGF-II RADIOIMMUNOASSAYS - IMPROVEMENT OF DETERMINATIONS IN ACID ETHANOL EXTRACTS BY THE USE OF TRUNCATED IGF-I AS RADIOLIGAND
    BANG, P
    ERIKSSON, U
    SARA, V
    WIVALL, IL
    HALL, K
    [J]. ACTA ENDOCRINOLOGICA, 1991, 124 (06): : 620 - 629
  • [3] Development of High-Throughput Chemical Extraction Techniques and Quantitative HPLC-MS/MS (SRM) Assays for Clinically Relevant Plasma Proteins
    Barton, Chris
    Kay, Richard G.
    Gentzer, Wolfgang
    Vitzthum, Frank
    Pleasance, Steve
    [J]. JOURNAL OF PROTEOME RESEARCH, 2010, 9 (01) : 333 - 340
  • [4] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [5] Approach to the determination of insulin-like-growth-factor-I (IGF-I) concentration in plasma by high-performance liquid chromatography-ion trap mass spectrometry: use of a deconvolution algorithm for the quantification of multiprotonated molecules in electrospray ionization
    Bobin, S
    Popot, MA
    Bonnaire, Y
    Tabet, JC
    [J]. ANALYST, 2001, 126 (11) : 1996 - 2001
  • [6] Quantification of human insulin-like growth factor-1 and qualitative detection of its analogues in plasma using liquid chromatography/electrospray ionisation tandem mass spectrometry
    Bredehoeft, Michael
    Schaenzer, Wilhelm
    Thevis, Mario
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (04) : 477 - 485
  • [7] RADIOIMMUNOASSAY FOR INSULIN-LIKE GROWTH FACTOR-I - SOLUTIONS TO SOME POTENTIAL PROBLEMS AND PITFALLS
    BREIER, BH
    GALLAHER, BW
    GLUCKMAN, PD
    [J]. JOURNAL OF ENDOCRINOLOGY, 1991, 128 (03) : 347 - 357
  • [8] Heterophilic antibodies may be a cause of falsely low total IGF1 levels
    Brugts, M. P.
    Luermans, J. G. L. M.
    Lentjes, E. G. W. M.
    van Trooyen-van Vrouwerff, N. J.
    van der Horst, F. A. L.
    Slee, P. H. Th J.
    Lamberts, S. W. J.
    Janssen, J. A. M. L.
    [J]. EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2009, 161 (04) : 561 - 565
  • [9] Isotope-labeled protein standards
    Brun, Virginie
    Dupuis, Alain
    Adrait, Annie
    Marcellin, Marlene
    Thomas, Damien
    Court, Magali
    Vandenesch, Francois
    Garin, Jerome
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (12) : 2139 - 2149
  • [10] The First International Standard for Insulin-like Growth Factor-1 (IGF-1) for immunoassay: Preparation and calibration in an international collaborative study
    Burns, C.
    Rigsby, P.
    Moore, M.
    Rafferty, B.
    [J]. GROWTH HORMONE & IGF RESEARCH, 2009, 19 (05) : 457 - 462