Selecting Mother Wavelet for Wavelet Analysis of On-Load Tap Changer Acoustic Emission

被引:4
|
作者
Cichon, A. [1 ]
Berger, P. [1 ,2 ]
Wotzka, D. [1 ]
机构
[1] Opole Univ Technol, Fac Elect Engn Automat Control & Comp Sci, PL-45271 Opole, Poland
[2] TurboCare Poland SA, PL-42701 Lubliniec, Poland
关键词
PARTIAL DISCHARGES; POWER TRANSFORMER;
D O I
10.12693/APhysPolA.128.310
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Wavelet transformation is one of the most popular tools for acoustic signal analysis. It provides good resolution both in time and frequency domains as well as wide choice of mother wavelets - this makes wavelet transformation a choice when flexible approach is required. However, selecting parameters of analysis can be difficult, especially regarding mother wavelet as different mother wavelets have various properties regarding number of vanishing moments and symmetry. This paper presents studies to determine the possibility of on-load tap changer wear detection by applying wavelet transformation. In research, different mother wavelets were selected and their usefulness was examined. Signals to be analyzed were obtained during on-load tap changer operation in different mechanical conditions - simulating devices wear in service. All measurements were performed on model very similar to real industrial on-load tap changer. Tests were conducted in controlled laboratory environment, reducing most of the possible disruptions.
引用
收藏
页码:310 / 314
页数:5
相关论文
共 18 条
  • [1] Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
    Cichon, Andrzej
    Borucki, Sebastian
    Boczar, Tomasz
    ARCHIVES OF ACOUSTICS, 2011, 36 (04) : 823 - 830
  • [2] Computer Simulation as an Aid in the Rating of a Transformer On-load Tap Changer
    Pasquotto de Lima, Paulo Afonso
    Lopes Cabral, Sergio Henrique
    IEEE ELECTRICAL INSULATION MAGAZINE, 2014, 30 (04) : 34 - 38
  • [3] Improvement in the performance of on-load tap changer transformers operating in series
    Smith, CA
    Redfern, MA
    Potts, S
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1905 - 1910
  • [4] Analysis of Vibration Signal for Power Transformer On-Load Tap Changer (OLTC) Condition Monitoring
    Seo, Junhyuck
    Ma, Hui
    Saha, Tapan K.
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [5] ON-LOAD TAP CHANGER (OLTC) SELECTION AND OPTIMIZATION IN LARGE POWER TRANSFORMERS
    Nambi, Shankar
    Kumar, Mohit
    Veeran, Kannan
    John, John K.
    2024 IEEE IAS PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE, PCIC, 2024, : 427 - 435
  • [6] AC Test Method for the Dynamic Characteristics of Transformer on-Load Tap Changer
    Zhou, Hongwei
    Dong, Tian
    Liu, Fu
    INTERNATIONAL CONFERENCE ON ELECTRICAL AND CONTROL ENGINEERING (ICECE 2015), 2015, : 523 - 530
  • [7] Using Deep Learning to Detect Anomalies in On-Load Tap Changer Based on Vibro-Acoustic Signal Features
    Dabaghi-Zarandi, Fataneh
    Behjat, Vahid
    Gauvin, Michel
    Picher, Patrick
    Ezzaidi, Hassan
    Fofana, Issouf
    ENERGIES, 2024, 17 (07)
  • [8] Mechanical Fault Diagnosis of On-load Tap Changer of Power Transformer by Clustering Algorithm
    Chen, Peilong
    Ma, Xiaohong
    Wang, Fenghua
    Xie, Fangxin
    Zhou, Dongxu
    2018 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2018,
  • [9] On Savitzky-Golay Filtering for Online Condition Monitoring of Transformer On-Load Tap Changer
    Seo, Junhyuck
    Ma, Hui
    Saha, Tapan Kumar
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (04) : 1689 - 1698
  • [10] A review on voltage control methods using on-load tap changer transformers for networks with renewable energy sources
    Sarimuthu, Charles R.
    Ramachandaramurthy, Vigna K.
    Agileswari, K. R.
    Mokhlis, Hazlie
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 62 : 1154 - 1161