Technetium-99m-tetrofosmin for parathyroid scintigraphy: A comparison with sestamibi

被引:0
|
作者
Fjeld, JG
Erichsen, K
Pfeffer, PF
Clausen, OPF
Rootwelt, K
机构
[1] UNIV OSLO,RIKSHOSP,DEPT CLIN CHEM,NUCL MED SECT,N-0027 OSLO,NORWAY
[2] UNIV OSLO,RIKSHOSP,DEPT MED ENDOCRINOL,N-0027 OSLO,NORWAY
[3] UNIV OSLO,RIKSHOSP,DEPT SURG B,N-0027 OSLO,NORWAY
[4] UNIV OSLO,RIKSHOSP,DEPT PATHOL,N-0027 OSLO,NORWAY
关键词
parathyroid scintigraphy; technetium-99m-tetrofosmin; technetium-99m-sestamibi;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Parathyroid scintigraphy with the new myocardial perfusion radiopharmaceutical Tc-99m-tetrofosmin was compared with Tc-99m-sestamibi scintigraphy using early and delayed imaging. Methods: The two preparations were administered on different days to the same 16 patients suffering from primary hyperparathyroidism. Anterior view gamma camera planar imaging (10-min acquisition) was performed in the period between 5 min and 3 hr after administration of the radiopharmaceutical. For most of the patients, a pertechnetate image of the thyroid was available for eyeball comparison when reading the tetrofosmin and sestamibi images. Imaging results were compared with those from histopathological examination after surgery. Results: On early images, all the adenomas visualized with sestamibi were equally well seen with tetrofosmin and Vice versa. In 6 of 11 scintigraphically detected neck adenomas, delayed imaging improved the adenoma Visualization with sestamibi. In contrast, this differential washout was never seen with tetrofosmin. Histopathological examination of excised tissue specimens after neck exploration (15 patients) or thoracotomy (one patient) revealed a parathyroid adenoma in all 16 patients. Our 12 scintigraphic findings were true-positives, while the remaining four scintigraphies were false-negatives, giving a diagnostic sensitivity of 75% with both preparations. The mediastinal adenoma was detected in a patient with a history of two unsuccessful neck explorations and one unsuccessful thoracotomy. Conclusion: Tetrofosmin has the same success rate as sestamibi for detection of parathyroid adenomas on scintigrams acquired immediately after injection. In contrast to sestamibi, delayed imaging has no diagnostic impact. Moreover, the thyroid/parathyroid differential washout of sestamibi failed in 5 of 11 neck adenomas here detected, indicating that delayed sestamibi washout is an unreliable diagnostic criterion. Therefore, whether sestamibi or tetrofosmin is preferred for parathyroid scintigraphy, thyroid scintigraphy seems mandatory.
引用
收藏
页码:831 / 834
页数:4
相关论文
共 50 条
  • [1] Technetium-99m-tetrofosmin for parathyroid scintigraphy: Comparison to thallium-technetium scanning
    Apostolopoulos, DJ
    Houstoulaki, E
    Giannakenas, C
    Alexandrides, T
    Spiliotis, J
    Nikiforidis, G
    Vlachojannis, JG
    Vassilakos, PJ
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (08) : 1433 - 1441
  • [2] Technetium-99m-tetrofosmin scintigraphy in pulmonary tuberculosis
    Degirmenci, B
    Kilinc, O
    Cirak, KA
    Capa, G
    Akpinar, O
    Halilcolar, H
    Durak, H
    Akkoclu, A
    Derebek, E
    Ucan, ES
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (12) : 2116 - 2120
  • [3] Differences between technetium-99m tetrofosmin and technetium-99m sestamibi in parathyroid scintigraphy
    Giordano, A
    Meduri, G
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03) : 347 - 347
  • [4] Differences between technetium-99m tetrofosmin and technetium-99m sestamibi in parathyroid scintigraphy
    Alessandro Giordano
    Guido Meduri
    European Journal of Nuclear Medicine, 1997, 24 : 347 - 347
  • [5] Assessment of thyroid nodules by technetium-99m-tetrofosmin scintigraphy
    Akcay, G
    Uslu, H
    Varoglu, E
    Tekin, SB
    Gundogdu, C
    BRITISH JOURNAL OF CLINICAL PRACTICE, 1997, 51 (01): : 5 - 7
  • [6] Parathyroid scintigraphy: Comparison of technetium-99m methoxyisobutylisonitrile and technetium-99m tetrofosmin studies
    Aigner, RM
    Fueger, GF
    Nicoletti, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (06): : 693 - 696
  • [7] Comparison of technetium-99m-MIBI, technetium-99m-tetrofosmin, ultrasound and MRI for localization of abnormal parathyroid glands
    Ishibashi, M
    Nishida, H
    Hiromatsu, Y
    Kojima, K
    Tabuchi, E
    Hayabuchi, N
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (02) : 320 - 324
  • [8] TECHNETIUM-99M-TETROFOSMIN IN DIPYRIDAMOLE-STRESS MYOCARDIAL SPECT IMAGING - INTRAINDIVIDUAL COMPARISON WITH TECHNETIUM-99M-SESTAMIBI
    FLAMEN, P
    BOSSUYT, A
    FRANKEN, PR
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (11) : 2009 - 2015
  • [9] Technetium-99m-tetrofosmin scintigraphy in patients with metastatic soft tissue sarcoma
    Karanikas, G
    Köstler, WJ
    Becherer, A
    Wiesner, K
    Dudczak, R
    Krainer, M
    Kletter, K
    ONCOLOGY REPORTS, 2002, 9 (05) : 1009 - 1013
  • [10] Technetium-99m-tetrofosmin scintigraphy, P-glycoprotein and lung cancer
    Tabuenca, MJ
    Vargas, JA
    Varela, A
    Salas, C
    Durántez, A
    Berrocal, JO
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (10) : 1830 - 1831