Calibration of blade tip-timing sensor for shrouded 40" last stage blade

被引:20
作者
Kubin, Z. [1 ]
Misek, T. [2 ]
Hlous, J. [2 ]
Dadakova, T. [2 ]
Kellner, J. [2 ]
Bachorec, T. [3 ]
机构
[1] Univ West Bohemia Pilsen, Plzen, Czech Republic
[2] Doosan Skoda Power Sro, Plzen, Czech Republic
[3] SVS FEM Sro, Brno, Czech Republic
基金
欧盟地平线“2020”;
关键词
Sensor; Blade tip-timing; Calibration; FEM Maxwell; Eddy-current;
D O I
10.1016/j.ymssp.2018.02.001
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Today's power generation market requests steam turbines of high efficiency, reliability and wide operation range. The last stage moving blades are designed with integral shroud, mid span, and fir-tree dovetail. The blades are continuously coupled by the blade untwist due to the centrifugal force, and thus the vibration control and increased structural damping are provided. Unfortunately this shroud complicates the blade vibration measurement using contactless methods. This paper describes in detail the Blade Tip-Timing measurement and calibration provided in test rig and in steam power station where the new eddy current and optical sensors were used together to measure blade vibration in various conditions. Detail calibration procedure for Blade Tip-Timing sensors will be presented as well as the results of the measurements and comparison to FEM Maxwell calculation and to FEM stress analysis. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:88 / 98
页数:11
相关论文
共 14 条
[1]  
Beauseroy P., NONINTRUSIVE TURBOMA
[2]  
Danek O., 2002, MAGNETOKINETICKA APA, P29
[3]  
Danek O., 2001, P C STRUCT SYST ID 5
[4]  
Hlous J, 2015, PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2015, VOL 7B
[5]  
Kadoy Y., 1995, JSME INT J, V38
[6]  
Kubin Zdenek, 2011, P ASME TURB EXP 2011
[7]  
Megerle B, 2013, PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 5B
[8]  
Misek T., 2014, DEV NEW 54 TITANIUM
[9]  
Misek T., 2009, P ASME TURB POW LAND
[10]  
Prchlik L, 2009, P ASME TURB 2009 POW