Numerical Simulation of Blood Flow in an Anatomically-Accurate Cerebral Venous Tree

被引:19
作者
Ho, Harvey [1 ]
Mithraratne, Kumar [1 ]
Hunter, Peter [1 ]
机构
[1] Univ Auckland, Bioengn Inst, Auckland 1010, New Zealand
关键词
Blood flow; cerebral; computed tomography angiography (CTA); one-dimensional (1-D) model; venous tree; FLUID-STRUCTURE INTERACTION; STEADY FLOW; COLLAPSIBLE TUBES; MATHEMATICAL-MODEL; PRESSURE; ARTERIAL; CIRCLE; WILLIS; CIRCULATION;
D O I
10.1109/TMI.2012.2215963
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Although many blood flow models have been constructed for cerebral arterial trees, few models have been reported for their venous counterparts. In this paper, we present a computational model for an anatomically accurate cerebral venous tree which was created from a computed tomography angiography (CTA) image. The topology of the tree containing 42 veins was constructed with 1-D cubic-Hermite finite element mesh. The model was formulated using the reduced Navier-Stokes equations together with an empirical constitutive equation for the vessel wall which takes both distended and compressed states of the wall into account. A robust bifurcation model was also incorporated into the model to evaluate flow across branches. Furthermore, a set of hierarchal inflow pressure boundary conditions were prescribed to close the system of equations. Some assumptions were made to simplify the numerical treatment, e. g., the external pressure was considered as uniform across the venous tree, and a vein was either distended or partially collapsed but not both. Using such a scheme we were able to evaluate the blood flow over several cardiac cycles for the large venous tree. The predicted results from the model were compared with ultrasonic measurements acquired at several sites of the venous tree and agreements have been reached either qualitatively (flow waveform shape) or quantitatively (flow velocity magnitude). We then discuss the significance of this venous model, its potential applications, and also present numerical experiments pertinent to limitations of the proposed model.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 28 条
[1]   Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows [J].
Alastruey, J. ;
Parker, K. H. ;
Peiro, J. ;
Byrd, S. M. ;
Sherwin, S. J. .
JOURNAL OF BIOMECHANICS, 2007, 40 (08) :1794-1805
[2]  
Anderson John David, 1995, Computational Fluid Dynamics, V206
[3]  
[Anonymous], [No title captured]
[4]   Utility of transesophageal echocardiography during port-access minimally invasive cardiac surgery [J].
Applebaum, RM ;
Cutler, WM ;
Bhardwaj, N ;
Colvin, SB ;
Galloway, AC ;
Ribakove, GH ;
Grossi, EA ;
Schwartz, DS ;
Anderson, RV ;
Tunick, PA ;
Kronzon, I .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (02) :183-188
[6]   Numerical solutions for unsteady gravity-driven flows in collapsible tubes: evolution and roll-wave instability of a steady state [J].
Brook, BS ;
Falle, SAEG ;
Pedley, TJ .
JOURNAL OF FLUID MECHANICS, 1999, 396 :223-256
[7]   DYNAMIC MODEL OF CIRCLE OF WILLIS [J].
CHAO, JC ;
HWANG, NHC .
JOURNAL OF BIOMECHANICS, 1971, 4 (02) :141-&
[8]   SUPERIOR VENA-CAVAL BLOOD-FLOW VELOCITIES IN ADULTS - A DOPPLER ECHOCARDIOGRAPHIC STUDY [J].
COHEN, ML ;
COHEN, BS ;
KRONZON, I ;
LIGHTY, GW ;
WINER, HE .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (01) :215-219
[9]   NUMERICAL SCHEMES FOR UNSTEADY FLUID-FLOW THROUGH COLLAPSIBLE TUBES [J].
ELAD, D ;
KATZ, D ;
KIMMEL, E ;
EINAV, S .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (01) :10-18
[10]   Numerical models of auto-regulation and blood flow in the cerebral circulation [J].
Ferrandez, A. ;
David, T. ;
Brown, M.D. .
Computer Methods in Biomechanics and Biomedical Engineering, 2002, 5 (01) :7-19