Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [41] Determination of copper and mercury in phosphate fertilizers employing direct solid sampling analysis and high resolution continuum source graphite furnace atomic absorption spectrometry
    Souza, Sidnei de Oliveira
    Francois, Luciane Luiza
    Borges, Aline Rocha
    Rodrigues Vale, Maria Goreti
    Oliveira Araujo, Rennan Geovanny
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 114 : 58 - 64
  • [42] Fast Sequential Determination of Zn, Fe, Mg, Ca, Na, and K in Infant Formulas by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry Using Ultrasound-Assisted Extraction
    Gamela, Raimundo R.
    Barrera, Eliana G.
    Duarte, Alvaro T.
    Boschetti, Wiliam
    da Silva, Marcia Messias
    Vale, Maria Goreti R.
    Dessuy, Morgana B.
    FOOD ANALYTICAL METHODS, 2019, 12 (06) : 1420 - 1428
  • [43] Method development for the determination of chlorine by high-resolution graphite furnace molecular absorption spectrometry via GaCl
    Tinas, Hande
    Akman, Suleyman
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 148 : 60 - 64
  • [44] Evaluation of pH and thermal stability of sorbent based on silica modified with polyaniline using high-resolution continuum source graphite furnace atomic absorption spectrometry and Raman spectroscopy
    Sowa, Ireneusz
    Wojciak-Kosior, Magdalena
    Draczkowski, Piotr
    Szwerc, Wojciech
    Tylus, Jolanta
    Pawlikowski, Andrzej
    Kocjan, Ryszard
    MICROCHEMICAL JOURNAL, 2015, 118 : 88 - 94
  • [45] A comparison of laser ablation-inductively coupled plasma-mass spectrometry and high-resolution continuum source graphite furnace molecular absorption spectrometry for the direct determination of bromine in polymers
    de Gois, Jefferson S.
    Van Malderen, Stijn J. M.
    Cadorim, Heloisa R.
    Welz, Bernhard
    Vanhaecke, Frank
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 132 : 50 - 55
  • [46] Sequential Multi-Element Determination of Hydride-Forming Elements (As, Bi, Cd, In, Pb, Se, Te, Tl) by High-Resolution Continuum Source Atom Trapping-Flame Atomic Absorption Spectrometry
    Matusiewicz, H.
    Krawczyk, M.
    CHEMIA ANALITYCZNA, 2009, 54 (05): : 949 - 973
  • [47] Evaluation of Brazilian and Venezuelan Crude Oil Samples by Means of the Simultaneous Determination of Ni and V as Their Total and Non-volatile Fractions Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Quadros, Daiane P. C.
    Chaves, Eduardo S.
    Lepri, Fabio G.
    Borges, Daniel L. G.
    Welz, Bernhard
    Becker-Ross, Helmut
    Curtius, Adilson J.
    ENERGY & FUELS, 2010, 24 (11) : 5907 - 5911
  • [48] Evaluation of dried matrix spot sampling for total sulphur determination in automotive gasoline by high-resolution continuum source molecular absorption spectrometry and direct solid sample analysis
    Kolling, Leandro
    Dessuy, Morgana Bazzan
    Rodrigues Vale, Maria Goreti
    da Silva, Marcia Messias
    TALANTA, 2022, 238
  • [49] A new concept of efficient therapeutic drug monitoring using the high-resolution continuum source absorption spectrometry and surface enhanced Raman spectroscopy
    Xing, Yanlong
    Fuss, Harald
    Lademann, Juergen
    Huang, Mao Dong
    Becker-Ross, Helmut
    Florek, Stefan
    Patzelt, Alexa
    Meinke, Martina C.
    Jung, Sora
    Esser, Norbert
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 142 : 91 - 96
  • [50] Development of analytical methods for the determination of copper and manganese in infant formula using high resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Gamela, Raimundo R.
    Duarte, Alvaro T.
    Barrera, Eliana G.
    Welz, Bernhard
    Dessuy, Morgana B.
    da Silva, Marcia Messias
    Vale, Maria Goreti R.
    ANALYTICAL METHODS, 2017, 9 (15) : 2321 - 2327