Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [31] Study of sulfur oxidation products by pyrolysis high-resolution mass spectrometry
    Frank, AJ
    Turecek, F
    EUROPEAN MASS SPECTROMETRY, 1999, 5 (05): : 375 - 384
  • [32] Optimization of high-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of selected trace elements in whole blood samples
    Wojciak-Kosior, Magdalena
    Szwerc, Wojciech
    Strzemski, Maciej
    Wichlacz, Zoltan
    Sawicki, Jan
    Kocjan, Ryszard
    Latalski, Michal
    Sowa, Ireneusz
    TALANTA, 2017, 165 : 351 - 356
  • [33] Determination of Trace Lead in Environmental Water by Cloud Point Extraction-High Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Sun Bo-si
    Ren Ting
    Zhao Li-jiao
    Zhong Ru-gang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (10) : 2847 - 2852
  • [34] Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
    Araujo, Rennan G. O.
    Vignola, Fabiola
    Castilho, Ivan N. B.
    Welz, Bernhard
    Vale, Maria Goreti R.
    Smichowski, Patricia
    Ferreira, Sergio L. C.
    Becker-Ross, Helmut
    MICROCHEMICAL JOURNAL, 2013, 109 : 36 - 40
  • [35] Determination of mercury in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
    Araujo, Rennan G. O.
    Vignola, Fabiola
    Castilho, Ivan N. B.
    Borges, Daniel L. G.
    Welz, Bernhard
    Vale, Maria Goreti R.
    Smichowski, Patricia
    Ferreira, Sergio L. C.
    Becker-Ross, Helmut
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 378 - 382
  • [36] Determination of Cr, Cu and Pb in industrial waste of oil shale using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    dos Passos, Adenilde S.
    Tonon, Gabriele F.
    Nakadi, Flavio V.
    Mangrich, Antonio S.
    de Andrade, Jailson B.
    Welz, Bernhard
    Vale, Maria Goreti R.
    ANALYTICAL METHODS, 2018, 10 (29) : 3645 - 3653
  • [37] High-resolution continuum source quartz tube atomic absorption spectrometry for the determination of As, Sb, Bi, Hg, Se and Te in food and environmental matrices after chemical vapor generation
    Szeredai, Bettina Dora
    Frentiu, Tiberiu
    Muntean, Norbert
    Dudu, Adrian-Ioan
    Covaci, Eniko
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (04) : 942 - 953
  • [38] Present-Day Possibilities of High-Resolution Continuous-Source Electrothermal Atomic Absorption Spectrometry
    Filatova, D. G.
    Es'kina, V. V.
    Baranovskaya, V. B.
    Karpov, Yu. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (05) : 563 - 568
  • [39] Selection of Iron Absorption Lines for Sequential Internal Standard Method for Accurate Determination of Nickel in Steel Samples by Flame Atomic Absorption Spectrometry Using a High-resolution Continuum-light-source Apparatus
    Itagaki, Toshiko
    Ashino, Tetsuya
    Wagatsuma, Kazuaki
    BUNSEKI KAGAKU, 2017, 66 (07) : 515 - 520
  • [40] Determination of Chlorine in Crude Oil by High-Resolution Continuum Source Graphite Furnace Molecular Absorption Spectrometry Using AlCl, InCl, and SrCl Molecules
    Enders, Michele S. P.
    Gomes, Alexandre O.
    Oliveira, Raphael F.
    Guimaraes, Regina C. L.
    Mesko, Marcia F.
    Flores, Erico M. M.
    Mueller, Edson I.
    ENERGY & FUELS, 2016, 30 (05) : 3637 - 3643