Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [21] Micro-sampling method based on high-resolution continuum source graphite furnace atomic absorption spectrometry for calcium determination in blood and mitochondrial suspensions
    Gomez-Nieto, Beatriz
    Jesus Gismera, Ma
    Teresa Sevilla, Ma
    Satrustegui, Jorgina
    Procopio, Jesus R.
    TALANTA, 2017, 170 : 15 - 21
  • [22] Determination of antimony in airborne particulate matter collected on filters using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Araujo, Rennan G. O.
    Welz, Bernhard
    Castilho, Ivan N. B.
    Vale, Maria Goreti R.
    Smichowski, Patricia
    Ferreira, Sergio L. C.
    Becker-Ross, Helmut
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (04) : 580 - 584
  • [23] Multivariate optimization of ultrasound-assisted extraction for determination of Cu, Fe, Ni and Zn in vegetable oils by high-resolution continuum source atomic absorption spectrometry
    Trindade, Alex S. N.
    Dantas, Alailson F.
    Lima, Daniel C.
    Ferreira, Sergio L. C.
    Teixeira, Leonardo S. G.
    FOOD CHEMISTRY, 2015, 185 : 145 - 150
  • [24] Speciation of Chromium in Water Samples after Dispersive Liquid-Liquid Microextraction, and Detection by Means of High-Resolution Continuum Source Atomic Absorption Spectrometry
    Porto, Daniele S.
    Akiba, Naomi
    de Oliveira, Marcone Augusto L.
    Gaubeur, Ivanise
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (02) : 266 - +
  • [25] Direct determination of fluorine in niobium oxide using slurry sampling electrothermal high-resolution continuum source molecular absorption spectrometry
    Huang, Mao Dong
    Becker-Ross, Helmut
    Okruss, Michael
    Geisler, Sebastian
    Florek, Stefan
    Richter, Silke
    Meckelburg, Angela
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 94-95 : 34 - 38
  • [26] Acquiring Information on the Total Content and Speciation of Silicon in Petroleum Products/Fuels Using High-Resolution Continuum Source Flame Atomic Absorption Spectrometry and Wavelength-Dispersive X-ray Fluorescence
    Kowalewska, Zofia
    Brzezinska, Karolina
    Cikorska, Katarzyna
    Pilarczyk, Janusz
    Gosciniak, Lukasz
    ENERGY & FUELS, 2019, 33 (01) : 215 - 227
  • [27] DETERMINATION OF LEAD IN HUMAN HAIR BY HIGH RESOLUTION CONTINUUM SOURCE GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MICROWAVE DIGESTION AND SOLID SAMPLING
    Zhao, Li-Jiao
    Ren, Ting
    Zhong, Ru-Gang
    ANALYTICAL LETTERS, 2012, 45 (16) : 2467 - 2481
  • [28] Investigation of spectral interference in the determination of Pb in road dust using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Fick, Susane Schossler
    Nakadi, Flavio Venancio
    Fujiwara, Fabian
    Smichowski, Patricia
    Vale, Maria Goreti R.
    Welz, Bernhard
    de Andrade, Jailson B.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (04) : 593 - 602
  • [29] Determination of cadmium, chromium and copper in vegetables of the Solanaceae family using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Pozzatti, Marianna
    Borges, Aline R.
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Welz, Bernhard
    ANALYTICAL METHODS, 2017, 9 (02) : 329 - 337
  • [30] Method development for the determination of thallium in coal using solid sampling graphite furnace atomic absorption spectrometry with continuum source, high-resolution monochromator and CCD array detector
    Silva, AF
    Borges, DLG
    Welz, B
    Vale, MGR
    Silva, MM
    Klassen, A
    Heitmann, U
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (06) : 841 - 850