Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [11] Simultaneous determination of cadmium, iron and tin in canned foods using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Leao, Danilo J.
    Junior, Mario M. S.
    Brandao, Geovani C.
    Ferreira, Sergio L. C.
    TALANTA, 2016, 153 : 45 - 50
  • [12] Investigation of chemical modifiers for the direct determination of arsenic in fish oil using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Pereira, Ederson R.
    de Almeida, Tarcisio S.
    Borges, Daniel L. G.
    Carasek, Eduardo
    Welz, Bernhard
    Feldmann, Joerg
    del Campo Menoyo, Javier
    TALANTA, 2016, 150 : 142 - 147
  • [13] Application of experimental design for optimization of erbium determination by high-resolution continuum source electrothermal atomic absorption spectrometry using lanthanum as a chemical modifier
    Aghabalazadeh, Sajjad
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    SPECTROSCOPY LETTERS, 2016, 49 (07) : 491 - 497
  • [14] Solid sampling determination of lithium and sodium additives in microsamples of yttrium oxyorthosilicate by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Laczai, Nikoletta
    Kovacs, Laszlo
    Peter, Agnes
    Bencs, Laszlo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 117 : 8 - 15
  • [15] A simple and fast procedure for the determination of Al, Cu, Fe and Mn in biodiesel using high-resolution continuum source electrothermal atomic absorption spectrometry
    Quadros, Daiane P. C.
    Rau, Martinho
    Idrees, Muhammad
    Chaves, Eduardo S.
    Curtius, Adilson J.
    Borges, Daniel L. G.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 373 - 377
  • [16] Determination of Sulfur in Grape and Apricot Samples Using High-resolution Continuum Source Electrothermal Molecular Absorption Spectrometry
    Arslan, Yasin
    Broekaert, J. A. C.
    Kula, Ibrahim
    ANALYTICAL SCIENCES, 2018, 34 (07) : 831 - 836
  • [17] Determination of chlorine via the CaCl molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry and direct solid sample analysis
    Guarda, Ananda
    Araniendia, Maite
    Andres, Irene
    Garcia-Ruiz, Esperanza
    do Nascimento, Paulo Cicero
    Resano, Martin
    TALANTA, 2017, 162 : 354 - 361
  • [18] Multi-Element Determination of Trace Elements in B7-diesel Oil by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry
    dos Santos, Heldiane S.
    de Jesus, Alexandre
    Laroque, Diane O.
    Piatnicki, Clarisse M. S.
    da Silva, Marcia M.
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 8 (30): : 59 - 70
  • [19] Extraction induced by emulsion breaking for simultaneous determination of Co, Fe and Ni in petroleum asphalt cement by high-resolution continuum source atomic absorption spectrometry
    Adolfo, Franciele Rovasi
    do Nascimento, Paulo Cicero
    Bohrer, Denise
    Viana, Carine
    de Carvalho, Leandro Machado
    Coutinho Cravo, Margareth C.
    Nascimento, Luis
    FUEL, 2020, 277 (277)
  • [20] Assessment of palladium nanoparticles as chemical modifier for lead determination in leached extracts from petroleum waste by high-resolution continuum source atomic absorption spectrometry
    Coelho, Karine S.
    Chaves, Eduardo S.
    Borges, Daniel L. G.
    Krzyzaniak, Sindy R.
    Rocha, Rafael C. C.
    Pierre, Tatiana D. Saint'
    Azzolin Frescura Bascunan, Vera Lucia
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 104 (16) : 4073 - 4088