Fractional-Order Sliding Mode Control for D-STATCOM Connected Wind Farm Based DFIG Under Voltage Unbalanced

被引:23
作者
Kerrouche, K. D. E. [1 ]
Wang, L. [1 ]
Mezouar, A. [2 ]
Boumediene, L. [2 ]
Van den Bossche, A. [3 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100091, Peoples R China
[2] Tahar Moulay Univ, Fac Technol, Electrotech Engn Lab, Sidon, Algeria
[3] Elect Energy LAB EELAB, Sint Pietersnieuwstr 41, B-9000 Ghent, Belgium
关键词
Doubly fed induction generator; D-STATCOM; Fractional-order sliding mode control; LVRT; FAULT RIDE-THROUGH; VECTOR CONTROL; SYSTEM; SUPERCAPACITOR; ENHANCEMENT; CAPABILITY; GENERATION; TURBINE;
D O I
10.1007/s13369-018-3412-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper studies the use of distribution static synchronous compensator (D-STATCOM) integrated with wind farm based on doubly fed induction generators. The short-term energy storage system based on a supercapacitor is introduced in this study to improve the operation of D-STATCOM. The dynamic performances of the grid-connected wind farm with D-STATCOM are enhanced by the proposed control scheme, which is based on fractional-order sliding mode control theory with dual-sequence decomposition technique. Some results of simulation show that, under an unbalanced grid voltage conditions, the proposed control strategy for the D-STATCOM not only eliminates effectively the oscillations of the active and reactive powers exchanged between the wind generator and the grid but also achieves the symmetrical and sinusoidal grid currents with less harmonics.
引用
收藏
页码:2265 / 2280
页数:16
相关论文
共 37 条
[1]   Design and real time implementation of fuzzy switched controller for single phase active power filter [J].
Afghoul, Hamza ;
Krim, Fateh ;
Chikouche, Djamel ;
Beddar, Antar .
ISA TRANSACTIONS, 2015, 58 :614-621
[2]   Stability of active disturbance rejection control for uncertain systems: A Lyapunov perspective [J].
Aguilar-Ibanez, Carlos ;
Sira-Ramirez, Hebertt ;
Angel Acosta, Jose .
INTERNATIONAL JOURNAL OF ROBUST AND NONLINEAR CONTROL, 2017, 27 (18) :4541-4553
[3]   Coordinated reactive power management in power networks with wind turbines and FACTS devices [J].
Amaris, Hortensia ;
Alonso, Monica .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) :2575-2586
[4]   Fault ride-through enhancement using an enhanced field oriented control technique for converters of grid connected DFIG and STATCOM for different types of faults [J].
Ananth, D. V. N. ;
Kumar, G. V. Nagesh .
ISA TRANSACTIONS, 2016, 62 :2-18
[5]  
[Anonymous], 1991, APPL NONLINEAR CONTR, V199
[6]  
Baranowski J, 2015, 2015 20TH INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN AUTOMATION AND ROBOTICS (MMAR), P116, DOI 10.1109/MMAR.2015.7283857
[7]   Control of a wind energy conversion system equipped by a DFIG for active power generation and power quality improvement [J].
Boutoubat, M. ;
Mokrani, L. ;
Machmoum, M. .
RENEWABLE ENERGY, 2013, 50 :378-386
[8]  
Chebabhi A, 2016, J POWER TECHNOL, V96, P15
[9]   CONTROL OF TWO ELECTRICAL PLANTS [J].
de Jesus Rubio, Jose ;
Lopez, Jesus ;
Pacheco, Jaime ;
Encinas, Rodrigo .
ASIAN JOURNAL OF CONTROL, 2018, 20 (04) :1504-1518
[10]   Robust feedback linearization for nonlinear processes control [J].
de Jesus Rubio, Jose .