Optimization of capillary liquid chromatography with electrochemical detection for determining femtogram levels of baicalin and baicalein on the basis of the FUMI theory

被引:10
作者
Kotani, Akira [1 ]
Kojima, Satoshi [1 ]
Hayashi, Yuzuru [2 ]
Matsuda, Rieko [2 ]
Kusu, Fumiyo [1 ]
机构
[1] Tokyo Univ Pharm & Life Sci, Sch Pharm, Tokyo 1920392, Japan
[2] Natl Inst Hlth Sci, Setagaya Ku, Tokyo 1588501, Japan
关键词
Capillary liquid chromatography; Electrochemical detection; FUMI theory; Optimization;
D O I
10.1016/j.jpba.2008.08.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary liquid chromatography with electrochemical detection (CLC-ECD) was developed for determining the femtogram levels of baicalin and baicalein. The CLC-ECD system and the experimental conditions were optimized based on the precision (=information content) phi and efficiency (=information content/time) theta, which were calculated from a relative standard deviation (R.S.D.) by a chemometric tool called the FUMI theory. When CLC-ECD was established using a capillary column (Inertsil ODS-3, 150 mm x 0.2 mm i.d.), a sample injector fitted witha 0.2 mu Linjection loop, an applied potential of +650 mV vs. Ag/AgCl, and a flow rate at 1.8 mu L/min, baicalin and baicalein were determined at femtogram levels. Moreover, the present method was validated using a chemometric tool and a conventional method. Since the FUMI theory makes it possible to predict R.S.D. without repetitive measurements, the chemometric tool saves considerable amounts of chemicals and experimental time, and was found to be useful for the optimization of conditions and validation for determination by CLC-ECD. The present method was applied to the analysis of Japanese Pharmacopoeia Scutellaria Root and Scutellaria baicalensis Georgi for determining baicalin and baicalein.
引用
收藏
页码:780 / 787
页数:8
相关论文
共 46 条
[1]   MICROBORE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION FOR THE CONTROL OF PHENOLIC ANTIOXIDANTS IN DRUGS AND FOODS [J].
BOUSSENADJI, R ;
PORTHAULT, M ;
BERTHOD, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (01) :71-78
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS WITH ELECTROCHEMICAL DETECTION OF BIOGENIC-AMINES USING MICROBORE COLUMNS [J].
CHENG, FC ;
KUO, JS .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 665 (01) :1-13
[3]  
Day Jr R.A., 1991, Quantitative Analysis
[4]   A better global resolution function and a novel iterative stochastic search method for optimization of high-performance liquid chromatographic separation [J].
Dharmadi, Y ;
Gonzalez, R .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1070 (1-2) :89-101
[5]  
GAUTSCHI K, 1993, EUR J CLIN CHEM CLIN, V31, P433
[6]   DEDUCTIVE PREDICTION OF MEASUREMENT PRECISION FROM SIGNAL AND NOISE IN LIQUID-CHROMATOGRAPHY [J].
HAYASHI, Y ;
MATSUDA, R .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2874-2881
[7]   Probabilistic approach to confidence intervals of linear calibration [J].
Hayashi, Y ;
Matsuda, R ;
Poe, RB .
ANALYST, 1996, 121 (05) :591-599
[8]  
HAYASHI Y, 1990, ANAL SCI, V6, P15, DOI 10.2116/analsci.6.15
[9]   SHANNON-INFORMATION RETRIEVED FROM OVERLAPPED CHROMATOGRAPHIC PEAKS WITH KALMAN FILTER [J].
HAYASHI, Y ;
YOSHIOKA, S ;
TAKEDA, Y .
ANALYTICAL SCIENCES, 1989, 5 (03) :329-334
[10]   TOTAL CHROMATOGRAPHIC OPTIMIZATION (TOCO) .2. PRECISION AND EFFICIENCY OF ANALYSIS [J].
HAYASHI, Y ;
MATSUDA, R .
CHROMATOGRAPHIA, 1990, 30 (3-4) :171-175