Performance analysis of building integrated with photovoltaic thermal system and traditional rooftop photovoltaic system

被引:0
作者
Mishra, Gourav Kumar [1 ]
Bhatti, T. S. [1 ]
Tiwari, G. N. [2 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
[2] BERS, 11B,Gyan Khand 4, Ghaziabad 201010, UP, India
来源
PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY (TAP ENERGY): EXPLORING ENERGY SOLUTIONS FOR AN INTELLIGENT POWER GRID | 2017年
关键词
BiSPVT; Exergy; PV inclination; Standalone PV system; Rooftop PV system; TEMPERATURE-DEPENDENCE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a comparison of overall performance of Building integrated semi-transparent photovoltaic thermal (BiSPVT) system with traditional rooftop semi-transparent photovoltaic system (RtSPV) in outdoor condition is experimentally investigated. The numbers of PV modules in RtSPV and BiSPVT are 32 and 96 respectively of 75Wp each. To make the comparison between the two systems, the PV array of BiSPVT system is divided into three equal sets. Hence, electrically one set of PV array of BiSPVT system is equal to whole PV array of RtSPV system. The electrical components of both systems such as photovoltaic (PV) modules, cross sectional area of wires used, solar power conditioning unit (PCU), batteries etc. are identical. The experimental results for the above mentioned systems were obtained at 24th September, 2017 which was one of the clear day during offset of monsoon season in Varanasi, India. From previous experiments, under normal operation it was found that the electrical performance of BiSPVT was less than that of RtSPV system. This was due to acquired thermal energy by thermal room which ultimately increases the PV cell temperature. So in the work, on BiSPVT system water is flown (mass flow rate is 1.81 kg/sec on PV array) to bring down the PV cell temperature and check its performance. Moreover, the comparison of performance is made through water flow on PV array of BiSPVT system for intermittent duration (i.e. 10th to 14th hour) and RtSPV system without any water flow. It is found that the electrical performance of BiSPVT system in comparison to RtSPV system is increased.
引用
收藏
页数:6
相关论文
共 9 条
  • [1] Geotzberger A., 2005, PHOTOVOLTAIC SOLAR E
  • [2] Solar-dc Microgrid for Indian Homes: A Transforming Power Scenario
    Jhunjhunwala A.
    Lolla A.
    Kaur P.
    [J]. 1600, Institute of Electrical and Electronics Engineers Inc., United States (04): : 10 - 19
  • [3] Determining optimum tilt angles and orientations of photovoltaic panels in Sanliurfa, Turkey
    Kacira, M
    Simsek, M
    Babur, Y
    Demirkol, S
    [J]. RENEWABLE ENERGY, 2004, 29 (08) : 1265 - 1275
  • [4] Nema Savita, 2010, International Journal of Energy and Environment, V1, P487
  • [5] Rosen M. A., 1999, EXERGY INT J, V1, P3
  • [6] PV panel model based on datasheet values
    Sera, Dezso
    Teodorescu, Remus
    Rodriguez, Pedro
    [J]. 2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 2392 - +
  • [7] Temperature dependence of solar cell performance-an analysis
    Singh, Priyanka
    Ravindra, N. M.
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2012, 101 : 36 - 45
  • [8] On the temperature dependence of photovoltaic module electrical performance: A review of efficiency/power correlations
    Skoplaki, E.
    Palyvos, J. A.
    [J]. SOLAR ENERGY, 2009, 83 (05) : 614 - 624
  • [9] Tiwari GN, 2014, 2014 2ND INTERNATIONAL CONFERENCE ON GREEN ENERGY AND TECHNOLOGY (ICGET), P132, DOI 10.1109/ICGET.2014.6966678