Physiological noise reduction using volumetric functional magnetic resonance inverse imaging

被引:27
|
作者
Lin, Fa-Hsuan [2 ,3 ]
Nummenmaa, Aapo [3 ,4 ]
Witzel, Thomas [5 ]
Polimeni, Jonathan R. [3 ]
Zeffiro, Thomas A. [6 ]
Wang, Fu-Nien [1 ]
Belliveau, John W. [3 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu, Taiwan
[2] Natl Taiwan Univ, Inst Biomed Engn, Taipei 10764, Taiwan
[3] MGH HST Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Aalto Univ, Sch Sci & Technol, Dept Biomed Engn & Computat Sci, Espoo, Finland
[5] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[6] Massachusetts Gen Hosp, Neural Syst Grp, Charlestown, MA USA
基金
芬兰科学院; 美国国家卫生研究院;
关键词
event-related; inverse imaging; Inl; visual; MRI; fMRI; neuroimaging; inverse solution; SURFACE-BASED ANALYSIS; ECHO-PLANAR; BRAIN MOTION; FMRI; FLUCTUATIONS; REGISTRATION; ACQUISITION; SUPPRESSION; EIGENMODES; PARAMETERS;
D O I
10.1002/hbm.21403
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Physiological noise arising from a variety of sources can significantly degrade the detection of task-related activity in BOLD-contrast fMRI experiments. If whole head spatial coverage is desired, effective suppression of oscillatory physiological noise from cardiac and respiratory fluctuations is quite difficult without external monitoring, since traditional EPI acquisition methods cannot sample the signal rapidly enough to satisfy the Nyquist sampling theorem, leading to temporal aliasing of noise. Using a combination of high speed magnetic resonance inverse imaging (InI) and digital filtering, we demonstrate that it is possible to suppress cardiac and respiratory noise without auxiliary monitoring, while achieving whole head spatial coverage and reasonable spatial resolution. Our systematic study of the effects of different moving average (MA) digital filters demonstrates that a MA filter with a 2 s window can effectively reduce the variance in the hemodynamic baseline signal, thereby achieving 57%58% improvements in peak z-statistic values compared to unfiltered InI or spatially smoothed EPI data (FWHM = 8.6 mm). In conclusion, the high temporal sampling rates achievable with InI permit significant reductions in physiological noise using standard temporal filtering techniques that result in significant improvements in hemodynamic response estimation. Hum Brain Mapp 33:2815-2830, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:2815 / 2830
页数:16
相关论文
共 50 条
  • [41] Normative hippocampal volumetric measurements using magnetic resonance imaging
    Ozdemir, Meltem
    Soysal, Handan
    Eraslan, Onder
    Dilli, Alper
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (05) : 1464 - 1470
  • [42] Perception of Difficulty Using Functional Magnetic Resonance Imaging Data
    Ahmad, Fayyaz
    Talib, Bushra
    Ch, Safee Ullah
    PROCEEDINGS OF 2019 11TH INTERNATIONAL CONFERENCE ON COMPUTER AND AUTOMATION ENGINEERING (ICCAE 2019), 2019, : 37 - 40
  • [43] Decoding brain states using functional magnetic resonance imaging
    Lee D.
    Park B.
    Jang C.
    Park H.-J.
    Biomedical Engineering Letters, 2011, 1 (2) : 82 - 88
  • [44] Functional magnetic resonance imaging: Physiological background, technical aspects and prerequisites for clinical use
    Stippich, C
    Heiland, S
    Tronnier, V
    Mohr, A
    Sartor, K
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (01): : 43 - 49
  • [45] The utility of near-infrared spectroscopy in the regression of low-frequency physiological noise from functional magnetic resonance imaging data
    Cooper, R. J.
    Gagnon, Louis
    Goldenholz, Daniel M.
    Boas, David A.
    Greve, Douglas N.
    NEUROIMAGE, 2012, 59 (04) : 3128 - 3138
  • [46] Spatial and temporal resolution of functional magnetic resonance imaging
    Menon, RS
    Gati, JS
    Goodyear, BG
    Luknowsky, DC
    Thomas, CG
    BIOCHEMISTRY AND CELL BIOLOGY-BIOCHIMIE ET BIOLOGIE CELLULAIRE, 1998, 76 (2-3): : 560 - 571
  • [47] A Hitchhiker's Guide to Functional Magnetic Resonance Imaging
    Soares, Jose M.
    Magalhaes, Ricardo
    Moreira, Pedro S.
    Sousa, Alexandre
    Ganz, Edward
    Sampaio, Adriana
    Alves, Victor
    Marques, Paulo
    Sousa, Nuno
    FRONTIERS IN NEUROSCIENCE, 2016, 10
  • [48] Functional magnetic resonance imaging of the brain: A quick review
    Vaghela, Viratsinh
    Kesavadas, Chandrasekharan
    Thomas, Bejoy
    NEUROLOGY INDIA, 2010, 58 (06) : 65 - 71
  • [49] FUNCTIONAL MAGNETIC RESONANCE IMAGING FOR CORTICAL MAPPING IN EPILEPSY
    Kozak Lajos Rudolf
    Toth Vivien
    Barsi Peter
    Rudas Gabor
    IDEGGYOGYASZATI SZEMLE-CLINICAL NEUROSCIENCE, 2011, 64 (9-10): : 294 - 299
  • [50] Visual functional magnetic resonance imaging of preterm infants
    Lee, Wayne
    Donner, Elizabeth J.
    Nossin-Manor, Revital
    Whyte, Hilary E. A.
    Sled, John G.
    Taylor, Margot J.
    DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2012, 54 (08) : 724 - 729