Radial artery tonometry: Moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement

被引:32
|
作者
Weiss, BM
Spahn, DR
Rahmig, H
Rohling, R
Pasch, T
机构
[1] Department of Anaesthesiology, University Hospital Zürich
[2] Department of Anaesthesiology, Klinikum Ludwigsburg
关键词
arterial pressure; measurement; measurement technique; measurement techniques; tonometry; oscillometry;
D O I
10.1093/bja/76.3.405
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Radial artery tonometry provides continuous measurement of non-invasive arterial pressure (CNAP) by a sensor positioned above the radial artery. An inflatable upper arm cuff enables intermittent oscillometric calibration. CNAP was compared with invasive radial artery pressure recordings from the opposite wrist in 22 high-risk surgical patients with an inter-arm oscillometric mean arterial pressure difference less than or equal to 10 mm Hg. Oscillometric, tonometric and invasive digital pressure values, and invasive and CNAP waveforms were obtained by the same instrument (Colin BP-508). Correlation coefficients (r) of invasive vs oscillometric values (n = 481 pairs) were 0.83, 0.90 and 0.92, and mean absolute errors of oscillometry were 7.6, 4.7, and 2.6 mm Hg for systolic, diastolic and mean arterial pressures, respectively. Correlation was poor for systolic (r = 0.80), diastolic (r = 0.77) and mean (r = 0.84) invasive vs CNAP values (n = 1375). Compared with oscillometry, mean absolute errors of 15.2, 10.9 and 9.4 mm Hg for systolic, diastolic and mean CNAP, respectively, were significantly (P < 0.001) higher. Mean prediction errors of CNAP, compared with invasive values, were -5.8 (so 14.2) mm Hg for systolic, +7.2 (8.3) mm Hg for diastolic and +3.9 (8.8) mm Hg for mean arterial pressure. Individual patient accuracy of CNAP was assessed as good (individual prediction error less than or equal to 5 (8) mm Hg and individual absolute error less than or equal to 10 mm Hg) in seven patients, as acceptable (less than or equal to 10 (12) and less than or equal to 15 mm Hg) in 11 patients, and as inadequate in four of 22 patients. Individual accuracy of oscillometry was good or acceptable in all 22 patients. The trend in CNAP changes (difference between consecutive measurements) was sufficiently accurate during induction of anaesthesia, as only 47 (7.6%), 14 (2.3%) and 27 (4.4%) of 616 systolic, diastolic and mean CNAP values differed by more than 10 mm Hg of invasive pressure trends. We conclude that: intermittent oscillometry provides accurate arterial pressure monitoring; CNAP measurements offer a reliable trend indicator of pressure changes during induction of anaesthesia and may be considered an alternative to invasive pressure measurements, should arterial cannulation be difficult in an awake patient; and accuracy of absolute CNAP values is only moderate and unpredictable, thus radial artery tonometry should not replace invasive monitoring in high-risk patients during major surgical procedures.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 50 条
  • [11] Continuous Non-invasive Blood Pressure Monitoring Based on Applanation Tonometry
    Ariyadamrogkwan, Chollitha
    Chitsakul, Kitiphol
    Treetriluxana, Suradaj
    2014 FOURTH JOINT INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONIC AND ELECTRICAL ENGINEERING (JICTEE 2014), 2014,
  • [12] Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement
    Harju, Jarkko
    Vehkaoja, Antti
    Kumpulainen, Pekka
    Campadello, Stefano
    Lindroos, Ville
    Yli-Hankala, Arvi
    Oksala, Niku
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (01) : 13 - 22
  • [13] Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement
    Jarkko Harju
    Antti Vehkaoja
    Pekka Kumpulainen
    Stefano Campadello
    Ville Lindroos
    Arvi Yli-Hankala
    Niku Oksala
    Journal of Clinical Monitoring and Computing, 2018, 32 : 13 - 22
  • [14] Reliability Of Non-Invasive Continuous Arterial Pressure Measurement Devices During Total Invasive Anaesthesia
    Huhle, R.
    Siegert, J.
    de Abreu, M. Gama
    Koch, T.
    Theilen, H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [15] CONTINUOUS NON-INVASIVE ARTERIAL PRESSURE (CNAP) MEASUREMENT: COMPARING THE CNAP DEVICE TO THE NON-INVASIVE BLOOD PRESSURE ARM CUFF DURING SURGERY
    Khera, J. K.
    Solangasenathirajan, S.
    Jones, M.
    Jonas, M.
    INTENSIVE CARE MEDICINE, 2013, 39 : S295 - S295
  • [16] Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
    Chemla, Denis
    Agnoletti, Davide
    Jozwiak, Mathieu
    Zhang, Yi
    Protogerou, Athanase D.
    Millasseau, Sandrine
    Blacher, Jacques
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (08):
  • [17] Evaluation of a continuous non-invasive arterial blood pressure monitoring device in comparison with an arterial blood pressure measurement in the ICU
    K Smolle
    M Schmid
    Critical Care, 15 (Suppl 1):
  • [18] NEXFIN CONTINUOUS NON-INVASIVE ARTERIAL BLOOD PRESSURE VALIDATED WITH INVASIVE BLOOD PRESSURE
    Martina, J. R.
    Westerhof, B. E.
    van Goudoever, J.
    de Beaumont, E. M.
    Hollmann, M. W.
    Lahpor, J. R.
    de Mol, B. A.
    van Lieshout, J. J.
    JOURNAL OF HYPERTENSION, 2009, 27 : S192 - S192
  • [19] Development of non-invasive measurement of myocardial contractility using left ventricular volume and pressure measured by gated myocardial SPECT and radial artery tonometry.
    Kim, KM
    Lee, DS
    Kim, YK
    Kim, SK
    Chung, JK
    Lee, MC
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 103P - 103P
  • [20] Sensor fusion for the accurate non-invasive measurement of blood pressure
    Nagy P.
    Jobbágy Á.
    Measurement: Sensors, 2022, 24