In this article, a series of ionene polymers were synthesized and used to coat fused-silica capillaries for the separation of recombinant and urinary human erythropoietin (rhEPO and uEPO) standards by CE. The influence of the charge density of coatings on the separation of rhEPO and uEPO glycoforms was investigated. Then, we further studied the method for fast separation and detection of rhEPO and uEPO standards by CE-ESI-MS. The influence of several CE and MS operating parameters, such as the concentration of CE running buffer, applied external pressure, and the composition and flow rate of sheath liquid on CE-ESI-MS was studied. The results demonstrated that when the capillary was permanently coated with 6,6-ionene and the pH value of acetic acid-ammonium acetate running buffer was 4.80 and 5.50, respectively, a significantly reproducible separation was achieved for rhEPO and uEPO glycoforms. In the online CE-ESI-MS experiments, we not only achieved the online MS signal of uEPO, but also obtained baseline separation of three major rhEPO glycoforms successfully and reproducibly on the 6,6-ionene-coated capillaries. Furthermore, the standard mixture of rhEPO and uEPO was separated, and two incompletely resolved peaks that were identified to be rhEPO and uEPO by the unique MS "fingerprint" were obtained. Additionally, the molecular weight of rhEPO and uEPO were verified and compared to the results by MALDI-TOF-MS. It can be concluded that, in contrast to other indirect methods, the online CE-ESI-MS technique with the combination of the advantages of both CE and MS shows great potential for the separation and detection of rhEPO doping directly in competitive sports.
引用
收藏
页码:2390 / 2400
页数:11
相关论文
共 48 条
[1]   Analysis of histones by on-line capillary zone electrophoresis-electrospray ionisation mass spectrometry [J].
Aguilar, C ;
Hofte, AJP ;
Tjaden, UR ;
van der Greef, J .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) :57-67
[2]  
Bahr U, 1997, J MASS SPECTROM, V32, P1111, DOI 10.1002/(SICI)1096-9888(199711)32:10<1111::AID-JMS567>3.0.CO
[3]  
2-Y
[4]  
BERNICE Y, 1997, ANAL CHEM, V69, P2510
[5]  
BRISTOW A, 1999, PHARMAEUROPA, V11, P296
[6]   Comparison of polymer coatings of capillaries for capillary electrophoresis with respect to their applicability to molecular imprinting and electrochromatography [J].
Bruggemann, O ;
Freitag, R ;
Whitcombe, MJ ;
Vulfson, EN .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :43-53
[7]   CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY [J].
CAI, JY ;
HENION, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :667-692
[8]   Capillary isoelectric focusing of erythropoietin glycoforms and its comparison with flat-bed isoelectric focusing and capillary zone electrophoresis [J].
Cifuentes, A ;
Moreno-Arribas, MV ;
de Frutos, M ;
Díez-Masa, JC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (02) :453-463
[9]   Noncovalent polycationic coatings for capillaries in capillary electrophoresis of proteins [J].
Cordova, E ;
Gao, JM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1370-1379
[10]  
CROMMELIN DJ, 1997, PHARM BIOTECHNOLOGY