A comparison of the plasma disappearance of iohexol and 99mTc-DTPA for the measurement of glomerular filtration rate (GFR) in diabetes

被引:28
作者
Houlihan, C
Scott, A
Jenkins, M
Parkin, D
Osicka, T
Jerums, G
机构
[1] Univ Melbourne, Endocrine Unit, Austin & Repatriat Med Ctr, Heidelberg, Vic 3084, Australia
[2] Univ Melbourne, Div Lab Med, Austin & Repatriat Med Ctr, Heidelberg, Vic 3084, Australia
[3] Univ Melbourne, Dept Nucl Med, Austin & Repatriat Med Ctr, Heidelberg, Vic 3084, Australia
[4] Univ Melbourne, Ctr PET, Austin & Repatriat Med Ctr, Heidelberg, Vic 3084, Australia
[5] Univ Melbourne, Ludwig Ctr Canc Res, Austin & Repatriat Med Ctr, Heidelberg, Vic 3084, Australia
来源
AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE | 1999年 / 29卷 / 05期
关键词
glomerular filtration rate; iohexol; capillary electrophoresis; Tc-99m-DTPA;
D O I
10.1111/j.1445-5994.1999.tb01617.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Changes in glomerular filtration rate (GFR) provide a valuable indicator of the progression of diabetic nephropathy. GFR is most commonly measured by the plasma clearance of radioisotopes, however, use of iohexol, a non-ionic radiocontrast medium, is a recently described alternative and has shown good agreement with inulin clearance. A one-compartment model is used for calculating GFR in most Australian centres but a two-compartment model is more accurate. Aims: To set up a non-radioisotopic method for assessment of GFR using iohexol, and to compare this with the currently used Tc-99m-diethylene-triamine-penta-acetic acid (DTPA) method. Secondly, to compare GFR results using an unmodified one-compartment model with a one-compartment model subjected to the Brochner-Mortensen modification. Methods: Twenty-one patients with diabetes had assessment of GFR with simultaneous measurements of Tc-99m-DTPA and iohexol plasma clearance. Plasma clearance was determined by the slope intercept method and then modified according to the Brochner-Mortensen equation. Plasma iohexol concentrations were determined by capillary electrophoresis. Results: There was no significant difference between iohexol and Tc-99m-DTPA derived GFR values, difference 4.3+/-7.7 mL/minute (mean +/- SD). This was despite Tc-99m-DTPA protein binding demonstrated in the range of 5-10%. Comparison of GFR;results using an unmodified one-compartment model with a Brochner-Mortensen corrected one-compartment model showed higher GFR values with the former, in the range of 20-30% for GFR values >100 mL/minute. Conclusion: Iohexol provides an efficient alternative to radioisotopic methods for serial measurement of GFR in diabetic patients with hyperfiltration, incipient and overt nephropathy. A one-compartment model with its inherent overestimation of GFR should be replaced by the Brochner-Mortensen modified one-compartment model.
引用
收藏
页码:693 / 700
页数:8
相关论文
共 30 条