T1 Mapping MOLLI 5(3)3 Acquisition Scheme Yields High Accuracy in 1.5 T Cardiac Magnetic Resonance

被引:3
作者
Krumm, Patrick [1 ]
Martirosian, Petros [2 ]
Brendel, Alexander [1 ]
Kuebler, Jens M. [1 ]
Brendel, Jan M. [1 ]
Gassenmaier, Sebastian [1 ]
Estler, Arne [1 ]
Gawaz, Meinrad [3 ]
Nikolaou, Konstantin [1 ]
Greulich, Simon [3 ]
机构
[1] Univ Tubingen, Dept Radiol Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Radiol, Sect Expt Radiol, D-72076 Tubingen, Germany
[3] Univ Tubingen, Dept Internal Med Cardiol & Angiol 3, D-72076 Tubingen, Germany
关键词
T1; mapping; cardiac magnetic resonance imaging; MOLLI; accuracy;
D O I
10.3390/diagnostics12112729
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To systematically compare two modified Look-Locker inversion recovery (MOLLI) T1 mapping sequences and their impact on (1) myocardial T1 values native, (2) post-contrast and (3) extracellular volume (ECV). Methods: 200 patients were prospectively included for 1.5 T CMR for work-up of ischemic or non-ischemic cardiomyopathies. To determine native and post-contrast T1 for ECV calculation, two different T1 mapping MOLLI acquisition schemes, 5(3)3 (designed for native scans with long T1) and 4(1)3(1)2 (designed for post-contrast scans with short T1), were acquired in identical mid-ventricular short-axis slices. Both schemes were acquired in native and post-contrast scans. Results: Datasets from 163 patients were evaluated (age 55 +/- 17 years; 38% female). Myocardial T1 native for 5(3)3 was 1017 +/- 42 ms vs. 956 +/- 40 ms for 4(1)3(1)2, with mean intraindividual difference -61 ms (p < 0.0001). Post-contrast myocardial T1 in patients was similar for both acquisition schemes, with 494 +/- 48 ms for 5(3)3 and 490 +/- 45 ms for 4(1)3(1)2 and mean intraindividual difference -4 ms. Myocardial ECV for 5(3)3 was 27.6 +/- 4% vs. 27 +/- 4% for 4(1)3(1)2, with mean difference -0.6 percentage points (p < 0.0001). Conclusions: The T1 MOLLI 5(3)3 acquisition scheme provides a reliable estimation of myocardial T1 for the clinically relevant range of long and short T1 values native and post-contrast. In contrast, the T1 MOLLI 4(1)3(1)2 acquisition scheme may only be used for post-contrast scans according to its designed purpose.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Cardiac Magnetic Resonance Imaging T1 and T2 Mapping in Systemic Lupus Erythematosus in Relation to Antimalarial Treatment
    Shalmon, Tamar
    Thavendiranathan, Paaladinesh
    Seidman, Michael A.
    Wald, Rachel M.
    Karur, Gauri Rani
    Harvey, Paula J.
    Akhtari, Shadi
    Osuntokun, Tosin
    Tselios, Kostantinos
    Gladman, Dafna D.
    Hanneman, Kate
    JOURNAL OF THORACIC IMAGING, 2023, 38 (03) : W33 - W42
  • [22] Optimized AIR and investigational MOLLI cardiac T1 mapping pulse sequences produce similar intra-scan repeatability in patients at 3T
    Hong, KyungPyo
    Collins, Jeremy
    Lee, Daniel C.
    Wilcox, Jane E.
    Markl, Michael
    Carr, James
    Kim, Daniel
    NMR IN BIOMEDICINE, 2016, 29 (10) : 1454 - 1463
  • [23] 3D SASHA myocardial T1 mapping with high accuracy and improved precision
    Nordio, Giovanna
    Bustin, Aurelien
    Henningsson, Markus
    Rashid, Imran
    Chiribiri, Amedeo
    Ismail, Tevfik
    Odille, Freddy
    Prieto, Claudia
    Michael Botnar, Rene
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (02) : 281 - 289
  • [24] Three-dimensional free breathing whole heart cardiovascular magnetic resonance T1 mapping at 3 T
    Rui Guo
    Zhensen Chen
    Yishi Wang
    Daniel A. Herzka
    Jianwen Luo
    Haiyan Ding
    Journal of Cardiovascular Magnetic Resonance, 20
  • [25] Three-dimensional free breathing whole heart cardiovascular magnetic resonance T1 mapping at 3 T
    Guo, Rui
    Chen, Zhensen
    Wang, Yishi
    Herzka, Daniel A.
    Luo, Jianwen
    Ding, Haiyan
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [26] Myocardial T1 values in healthy volunteers measured with saturation method using adaptive recovery times for T1 mapping (SMART1Map) at 1.5 T and 3 T
    Matsumoto, Shunsuke
    Okuda, Shigeo
    Yamada, Yoshitake
    Suzuki, Tatsuya
    Tanimoto, Akihiro
    Nozaki, Atsushi
    Jinzaki, Masahiro
    HEART AND VESSELS, 2019, 34 (11) : 1889 - 1894
  • [27] 3D SASHA myocardial T1 mapping with high accuracy and improved precision
    Giovanna Nordio
    Aurélien Bustin
    Markus Henningsson
    Imran Rashid
    Amedeo Chiribiri
    Tevfik Ismail
    Freddy Odille
    Claudia Prieto
    René Michael Botnar
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 281 - 289
  • [28] Recent Advances in T1 and T2 Mapping in the Assessment of Fulminant Myocarditis by Cardiac Magnetic Resonance
    Wheen, P.
    Armstrong, R.
    Daly, C. A.
    CURRENT CARDIOLOGY REPORTS, 2020, 22 (07)
  • [29] Cardiac MOLLI T1 mapping at 3.0 T: comparison of patient-adaptive dual-source RF and conventional RF transmission
    Michael Rasper
    Jonathan Nadjiri
    Alexandra S. Sträter
    Marcus Settles
    Karl-Ludwig Laugwitz
    Ernst J. Rummeny
    Armin M. Huber
    The International Journal of Cardiovascular Imaging, 2017, 33 : 889 - 897
  • [30] Cardiac MOLLI T1 mapping at 3.0 T: comparison of patient-adaptive dual-source RF and conventional RF transmission
    Rasper, Michael
    Nadjiri, Jonathan
    Straeter, Alexandra S.
    Settles, Marcus
    Laugwitz, Karl-Ludwig
    Rummeny, Ernst J.
    Huber, Armin M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (06) : 889 - 897