Rapid Screening of Urinary 1-Hydroxypyrene Glucuronide by Multisegment Injection-Capillary Electrophoresis-Tandem Mass Spectrometry: A High-Throughput Method for Biomonitoring of Recent Smoke Exposures

被引:16
|
作者
Gill, Biban [1 ]
Jobst, Karl [2 ]
Britz-McKibbin, Philip [1 ]
机构
[1] McMaster Univ, Dept Chem & Chem Biol, Hamilton, ON L8S 4M1, Canada
[2] Mem Univ Newfoundland, Dept Chem, St John, NF A1B 3X7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; CARDIOVASCULAR-DISEASE; OCCUPATIONAL-EXPOSURE; LIQUID-CHROMATOGRAPHY; US FIREFIGHTERS; WOOD SMOKE; METABOLITE; BIOMARKERS; IMPACT;
D O I
10.1021/acs.analchem.0c03212
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Urinary 1-hydroxypyrene (HP) is a widely used biomarker of polycyclic aromatic hydrocarbon exposure relevant for biomonitoring the deleterious health impacts from tobacco smoke and ambient air pollution, as well as the hazards of certain occupations. Conventional methods for urinary HP analysis based on liquid chromatography with native fluorescence detection or tandem mass spectrometry (MS/MS) and gas chromatography-mass spectrometry (GC-MS) are limited by low sample throughput and complicated sample workup protocols that are prone to bias. Herein, we introduce a high throughput method to directly analyze the intact glucuronide conjugate of HP (HP-G) in human urine after a simple acidified ether extraction procedure when using multisegment injection-capillary electrophoresis-tandem mass spectrometry (MSI-CE-MS/MS). Multiplexed analyses of 13 independent urine extracts are achieved in a single run (<3 min/sample) with stringent quality control while avoiding enzyme deconjugation and precolumn chemical derivatization. Method validation demonstrates good technical precision (CV = 7.7%, n = 45) and accuracy with a mean recovery of (93 +/- 3%) for urinary HP-G at three concentration levels with adequate detection limits (7 ng/L, S/N = 3). An interlaboratory method comparison of urine samples collected from firefighters deployed in the 2016 Fort McMurray wildfire also confirms good mutual agreement with an acceptable negative bias (mean bias = 15%, n = 55) when measuring urinary HP-G by MSI-CE-MS/MS as compared to total hydrolyzed urinary HP by GC-MS due to the low residual levels of free HP and its sulfate conjugate. This multiplexed separation platform is optimal for large-scale biomonitoring studies of air pollution relevant to global health as well as occupational smoke exposures in firefighters susceptible to dermal PAH absorption when using personal protective equipment.
引用
收藏
页码:13558 / 13564
页数:7
相关论文
共 3 条
  • [1] High-throughput screening of salivary polyamine markers for discrimination of colorectal cancer by multisegment injection capillary electrophoresis tandem mass spectrometry
    Igarashi, Kaori
    Ota, Sana
    Kaneko, Miku
    Hirayama, Akiyoshi
    Enomoto, Masanobu
    Katumata, Kenji
    Sugimoto, Masahiro
    Soga, Tomoyoshi
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1652
  • [2] Capillary Electrophoresis-Mass Spectrometry with Multisegment Injection and In-Capillary Preconcentration for High-Throughput and Sensitive Determination of Therapeutic Decapeptide Triptorelin in Pharmaceutical and Biological Matrices
    Piestansky, Juraj
    Cizmarova, Ivana
    Stefanik, Ondrej
    Matuskova, Michaela
    Horniakova, Andrea
    Majerova, Petra
    Mikus, Peter
    BIOMEDICINES, 2021, 9 (10)
  • [3] A high-throughput liquid chromatography tandem mass spectrometry method for the comparative determination of fluticasone propionate by reversed-phase liquid chromatography and capillary electrophoresis methods in pharmaceutical nasal sprays
    Sangoi, Maximiliano da Silva
    Wrasse, Micheli
    D'Avila, Felipe Bianchini
    Bernardi, Raquel Martini
    de Oliveira, Paulo Renato
    Dalmora, Sergio Luiz
    Bueno Rolim, Clarice Madalena
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2009, 15 (06) : 723 - 730