Determination of saquinavir in human plasma by high-performance liquid chromatography

被引:37
|
作者
Ha, HR [1 ]
Follath, F [1 ]
Bloemhard, Y [1 ]
Krahenbuhl, S [1 ]
机构
[1] UNIV ZURICH HOSP,DEPT INTERNAL MED,DIV CLIN PHARMACOL & TOXICOL,ZURICH,SWITZERLAND
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 694卷 / 02期
关键词
saquinavir;
D O I
10.1016/S0378-4347(97)00165-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed and characterized a high-performance liquid chromatography (HPLC) assay for the determination of saquinavir, an HIV protease inhibitor, in human plasma samples, Extraction of plasma samples with diethyl ether resulted in quantitative recovery of both saquinavir and its stereoisomer Ro 31-8533 which was used as an internal standard. The assay was performed isocratically using 5 mM H2SO4 (pH 3.5) and acetonitrile (75.5:24.5, v/v) containing 10 mM tetrabutylammonium hydrogen sulfate (TBA) as a mobile phase, a Nucleosil 3C8 column kept at 45 degrees C and UV detection at 240 nm, Using this method, saquinavir and Ro 31-8533 can be separated from endogenous substances, and in the concentration range of 5-110 ng/ml the relative standard deviations for the determination of saquinavir were below 5%. The detection Limit of saquinavir in human plasma was 1 ng/ml. The usefulness of the method was demonstrated by quantification of saquinavir in plasma of human subjects treated with 600 mg of saquinavir per os or 12 mg intravenously. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:427 / 433
页数:7
相关论文
共 41 条
  • [1] Simultaneous determination of indinavir, ritonavir and saquinavir in plasma by high-performance liquid chromatography
    Hsieh, SM
    Yu, HY
    Chang, SC
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2004, 103 (03) : 191 - 195
  • [2] Determination of saquinavir and ritonavir in human plasma by reversed-phase high-performance liquid chromatography and the analytical error function
    Albert, V
    Modamio, P
    Lastra, CF
    Mariño, EL
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (04) : 835 - 840
  • [3] Determination of saquinavir in human plasma, saliva, and cerebrospinal fluid by ion-pair high-performance liquid chromatography with ultraviolet detection
    Hoetelmans, RMW
    vanEssenberg, M
    Meenhorst, PL
    Mulder, JW
    Beijnen, JH
    JOURNAL OF CHROMATOGRAPHY B, 1997, 698 (1-2): : 235 - 241
  • [4] Simultaneous determination of the HIV protease inhibitors indinavir, amprenavir, saquinavir, ritonavir and nelfinavir in human plasma by high-performance liquid chromatography
    Yamada, H
    Kotaki, H
    Nakamura, T
    Iwamoto, A
    JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 85 - 89
  • [5] Simultaneous determination of ritonavir and saquinavir, two human immunodeficiency virus protease inhibitors, in human serum by high-performance liquid chromatography
    Frappier, S
    Breilh, D
    Diarte, E
    Ba, B
    Ducint, D
    Pellegrin, JL
    Saux, MC
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 714 (02): : 384 - 389
  • [6] Simultaneous determination of the HIV-protease inhibitors indinavir, nelfinavir, saquinavir and ritonavir in human plasma by reversed-phase high-performance liquid chromatography
    Hugen, PWH
    Verweij-van Wissen, CPWGM
    Burger, DM
    Wuis, EW
    Koopmans, PP
    Hekster, YA
    JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2): : 139 - 149
  • [7] Simultaneous determination of the HIV-protease inhibitors indinavir, amprenavir, ritonavir, saquinavir and nelfinavir in human plasma by reversed-phase high-performance liquid chromatography
    Sarasa-Nacenta, M
    López-Púa, Y
    Mallolas, J
    Blanco, JL
    Gatell, JM
    Carné, X
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 757 (02): : 325 - 332
  • [8] Simultaneous high-performance liquid chromatographic determination of the antiretroviral agents amprenavir, nelfinavir, ritonavir, saquinavir, delavirdine and efavirenz in human plasma
    Proust, V
    Toth, K
    Hulin, A
    Taburet, AM
    Gimenez, F
    Singlas, E
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 742 (02): : 453 - 458
  • [9] Simultaneous quantitative determination of the HIV protease inhibitors amprenavir, indinavir, nelfinavir, ritonavir and saquinavir in human plasma by ion-pair high-performance liquid chromatography with ultraviolet detection
    van Heeswijk, RPG
    Hoetelmans, RMW
    Harms, R
    Meenhorst, PL
    Mulder, JW
    Lange, JMA
    Beijnen, JH
    JOURNAL OF CHROMATOGRAPHY B, 1998, 719 (1-2): : 159 - 168
  • [10] Sensitive and specific determination of eight antiretroviral agents in plasma by high-performance liquid chromatography-mass spectrometry
    Rentsch, KM
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02): : 339 - 350