Poly(o-phenylenediamine) nanosphere-conjugated capture antibody immobilized on a glassy carbon electrode for electrochemical immunoassay of carcinoembryonic antigen

被引:25
作者
Xu, Ti-Sen [1 ]
Li, Xiang-Yong [1 ]
Xie, Zhao-Hui [1 ]
Li, Xue-Gui [1 ]
Zhang, Hai-Ying [1 ]
机构
[1] Dezhou Univ, Coll Life Sci, Key Lab Biotechnol & Biol Resource Utilizat Univ, Dezhou 253023, Shandong, Peoples R China
关键词
Electrochemical immunoassay; Differential pulse voltammetry; Cyclic voltammetry; Horseradish peroxidase; Poly(o-phenylenediamine) nanospheres; Nanoconjugation; GOLD NANOPARTICLES; ULTRASENSITIVE DETECTION; CANCER BIOMARKER; TUMOR-MARKERS; IMMUNOSENSOR; NANOPROBE; SIGNAL; DNA;
D O I
10.1007/s00604-015-1625-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on a new electrochemical immunosensor for the carcinoembryonic antigen (CEA; a model analyte). First, poly(o-phenylenediamine) nanospheres (PPDNSs) were synthesized by using a wet-chemistry method. The nanospheres were utilized as the support for immobilizing horseradish peroxidase-labeled polyclonal rabbit anti-human CEA antibody (HRP-anti-CEA) on a pretreated glassy carbon electrode (GCE) using glutaraldehyde as a crosslinker. In the presence of target CEA, an antigen-antibody immunocomplex formed on the electrode. This results in a partial inhibition of the active center of HRP and decreases the activity of HRP in terms of H2O2 reduction. The performance and factors influencing the performance of the immunoelectrode were studied. Under optimal conditions, the reduction current obtained from the anti-CEA-conjugated HRP (best at a working voltage of -265 mV vs. Ag/AgCl) is proportional to the CEA concentration in the 0.01 to 60 ng mL(-1) range, with a detection limit of 3.2 pg mL(-1). Non-specific adsorption was not observed. Relative standard deviations for intra-assay and inter-assay are < 8.3 % and < 9.7 %, respectively. The method was applied to the analysis of nine human serum samples, and a good relationship was found between the electrochemical immunoassay and the commercialized ELISA kit for human CEA.
引用
收藏
页码:2541 / 2549
页数:9
相关论文
共 38 条
  • [22] Electrochemical immunoassay for the biomarker 8-hydroxy-2'-deoxyguanosine using a glassy carbon electrode modified with chitosan and poly(indole-5-carboxylic acid)
    Pan, Deng
    Zhou, Qiang
    Rong, Shengzhong
    Zhang, Guangteng
    Zhang, Yannan
    Liu, Fenghai
    Li, Miaojing
    Chang, Dong
    Pan, Hongzhi
    MICROCHIMICA ACTA, 2016, 183 (01) : 361 - 368
  • [23] Preparation and characterization of a poly-o-phenylenediamine film modified glassy carbon electrode as a H2O2 sensor
    Zhai, Wenying
    Tian, Xiuying
    Yan, Yun
    Xu, Yuehua
    Zhao, Yuechun
    Liu, Youqin
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 2013, 91 (11): : 1077 - 1084
  • [24] Electrochemical Detection of o-Nitrophenol on a Poly(propyleneimine)-gold Nanocomposite Modified Glassy Carbon Electrode
    Ndlovu, Thabile
    Arotiba, Omotayo A.
    Krause, Rui W.
    Mamba, Bhekie B.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (08): : 1179 - 1186
  • [25] A disposable electrochemical immunosensor for carcinoembryonic antigen based on nano-Au/multi-walled carbon nanotubes-chitosans nanocomposite film modified glassy carbon electrode
    Huang, Ke-Jing
    Niu, De-Jun
    Xie, Wan-Zhen
    Wang, Wei
    ANALYTICA CHIMICA ACTA, 2010, 659 (1-2) : 102 - 108
  • [26] Duplex voltammetric immunoassay for the cancer biomarkers carcinoembryonic antigen and alpha-fetoprotein by using metal-organic framework probes and a glassy carbon electrode modified with thiolated polyaniline nanofibers
    Ping Zhang
    Hui Huang
    Nan Wang
    Huijuan Li
    Dazhong Shen
    Houyi Ma
    Microchimica Acta, 2017, 184 : 4037 - 4045
  • [27] Electrochemical immunoassay for the biomarker 8-hydroxy-2′-deoxyguanosine using a glassy carbon electrode modified with chitosan and poly(indole-5-carboxylic acid)
    Deng Pan
    Qiang Zhou
    Shengzhong Rong
    Guangteng Zhang
    Yannan Zhang
    Fenghai Liu
    Miaojing Li
    Dong Chang
    Hongzhi Pan
    Microchimica Acta, 2016, 183 : 361 - 368
  • [28] A novel electrochemical sensor of 4-nonylphenol based on a poly(ionic liquid) hollow nanosphere/gold nanoparticle composite modified glassy carbon electrode
    Ren, Jie
    Gu, Jinfen
    Tao, Li
    Yao, Mengqi
    Yang, Xiaoci
    Yang, Wu
    ANALYTICAL METHODS, 2015, 7 (19) : 8094 - 8099
  • [29] A kanamycin sensor based on an electrosynthesized molecularly imprinted poly-o-phenylenediamine film on a single-walled carbon nanohorn modified glassy carbon electrode
    Han, Shuang
    Li, Bingqian
    Song, Ze
    Pan, Sihao
    Zhang, Zhichao
    Yao, Hui
    Zhu, Shuyun
    Xu, Guobao
    ANALYST, 2017, 142 (01) : 218 - 223
  • [30] Enhanced electrochemical response of a modified glassy carbon electrode by poly(2-vinlypyridine-b-methyl methacrylate) conjugated gold nanoparticles for detection of nicotine
    Rahim, Sana
    Rauf, Asma
    Rauf, Saba
    Shah, Muhammad Raza
    Malik, Muhammad Imran
    RSC ADVANCES, 2018, 8 (62): : 35776 - 35786