The gas hold-up in bubble columns. I. The influence of hydrodynamic conditions

被引:0
|
作者
Pincovschi, I
Mihai, M
机构
[1] Univ Politehn Bucuresti, Fac Energet, Bucharest, Romania
[2] Univ Politehn Bucuresti, Fac Chim Ind, Bucharest 011061, Romania
来源
REVISTA DE CHIMIE | 2004年 / 55卷 / 02期
关键词
gas hold-up; bubble; dispersed system; homogenous and heterogenous flow regime;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
There are several methods to perform experimental measurements of the overall gas hold-up in bubble columns but none of them is considered to be a standard method for measuring this parameter The precision of measurements lies between 10-20%, and improvements to increase it for any of these methods are welcomed. This work presents improvements to liquid height variation method. Experimental measurements of gas hold-lip in a bubble column are correlated with flow regimes and bubble size distribution in a bubble column with porous plate gas distribution device.
引用
收藏
页码:126 / 129
页数:4
相关论文
共 50 条
  • [21] GAS HOLD-UP IN BUBBLE-COLUMNS FOR FISCHER-TROPSCH SYNTHESIS
    BUKUR, DB
    DALY, JG
    CHEMICAL ENGINEERING SCIENCE, 1987, 42 (12) : 2967 - 2969
  • [22] GAS HOLD-UP IN BUBBLE-COLUMNS WITH NON-NEWTONIAN LIQUIDS
    VATAI, G
    TEKIC, MN
    CHEMICAL ENGINEERING SCIENCE, 1987, 42 (01) : 166 - 169
  • [23] The overall gas hold-up of air - Viscoelastic liquids systems in bubble columns
    Mihai, M
    Pincovschi, I
    REVISTA DE CHIMIE, 2004, 55 (12): : 1031 - 1036
  • [24] PRESSURE AND GAS-DENSITY EFFECTS ON BUBBLE BREAK-UP AND GAS HOLD-UP IN BUBBLE-COLUMNS
    WILKINSON, PM
    VONDIERENDONCK, LL
    CHEMICAL ENGINEERING SCIENCE, 1990, 45 (08) : 2309 - 2315
  • [25] EFFECT OF ELECTROLYTE CONCENTRATION ON BUBBLE-SIZE AND GAS HOLD-UP IN BUBBLE-COLUMNS
    JAMIALAHMADI, M
    MULLERSTEINHAGEN, H
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1990, 68 (02): : 202 - 204
  • [26] Gas hold-up in aerated slugging columns
    Pinheiro, MNC
    Pinto, AMFR
    Campos, JBLM
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A8): : 1139 - 1146
  • [27] ULTRASONIC TECHNIQUE FOR CONTROL OF HOLD-UP PROFILES IN MULTISTAGE EXTRACTION COLUMNS.
    Kirou, Vassilios I.
    Tavlarides, Lawrence L.
    Bonnet, Julio C.
    Industrial and Engineering Chemistry Research, 1988, 27 (06): : 1084 - 1086
  • [28] The gas-hold up in bubble columns. III. The influence of tensioactive substances admixture in continuous phase
    Pincovschi, I
    Mihai, M
    REVISTA DE CHIMIE, 2005, 56 (02): : 183 - 189
  • [29] NEW METHOD TO PREDICT HOLD-UP AND PRESSURE DROP IN PACKED COLUMNS.
    Bemer, G.G.
    Kalis, G.A.J.
    1978, 56 (03): : 200 - 204
  • [30] Gas hold-up in aerated slugging columns
    Coelho, Pinheiro, M.N.
    Pinto, A.M.F.R.
    Campos, J.B.L.M.
    Chemical Engineering Research and Design, 2000, 78 (08) : 1139 - 1146